5
CUTTING A CAR KEY TO CODE
To cut the sample car key code
KZ92
press
then
then move the
currsor using the up down arrow key to
GM 10C 95+
and press
. Insert the suggested insert 1FL
and install the suggested key P1106 or equivalent. Now press
Turn the handle clockwise
until the blocks disappear and the numbers count down to 0 and the cutter starts. Now turn the
handle counterclockwise untill the first side of the key is cut and the cutter stops. Turn the key over
and press cut, turn the handle clockwise until the blocks disappear and the numbers count down to 0
and the cutter starts. Now turn the handle counterclockwise untill the second side of the key is cut.
ALWAYS MAKE SURE THE CUTTER HAS STOPPED BEFORE REMOVING A KEY
MAKE SURE THE MOTOR IS OFF BEFORE REMOVING THE
KEY.
CALIBRATING THE ITL950C
NOTE Ill IT IS POSSIBLE TO RUN THE CUTTER INTO THE VICE WITH IMPROPER
CALIBRATION. BE CERTAIN OF DEPTH CALIBRATION. YOU MAY ABORT THE CUTTING
OPERATION AT ANY TIME BY PRESSING THE RESET KEY. THIS WILL STOP THE CUTTER
AND RETURN THE KEY TO THE IDLE POSITION. DO NOT AT ANY TIME ALLOW THE
CUTTER TO TOUCH THE VICE, AS IT WILL DAMAGE THE CUTTER.
TO CHECK CALIBRATIONS
First select
MFG 391
this is
“Schlage”.
Next, place insert #2 in the vice jaw and slide a blank
onto it. Push the key along the top of the insert until the bottom shoulder comes up hard against the
insert. Check the right hand side of the vice. Make sure the insert is tight against the stop screw.
Tighten the vise and press
. When the cut is finished, remove the key and measure
the distance from the back of the blank to the bottom of the cut with a micrometer caliper. Subtract
the reading you get from the .335 thousand depth it should be and note the number down. Measure
the distance from the bow of the key to the center of the first cut. As above, subtract the reading from
the .231 thousand space it should be.
TO ADJUST CALIBRATIONS
Press the
keys to enter the
EDIT
mode and then press
.
The
display will show
EDIT
CALIBRATION.
Press
.
Now the display will show
ADJUST DP
BY
000.
If in our sample our depth reading is .340, .335 minus .340, equals -.005. On the keypad enter
.
Now the display will read
–005.
. To return to
EDIT CALIBRATION,
push the
key twice, and then press the
key. In our sample, if the space reading is .229, subtract this from
.231 and the answer is .003. Now press
and the display will read
003.
Press the
key
twice and follow display instructions to return to home.