14
SETTING SERIAL PORT PARAMETERS
SETTING BAUD RATE
Enter the EDIT mode by pressing the
keys. Press
twice to
enter the Serial port setup routine. Display will read
BAUD RATE =8.
Use the table
below to select a baud rate. For example to set the baud rate to 4800, locate the correct
baud rate (in this case 7). Now enter the selected baud rate
and press
to
save the new baud rate or
to erase or correct your entry. Pressing
with no
number entered and you will exit the Serial setup routine without changing the baud
rate.
BAUD RATE
SELECT CODE
75
1
150
2
300
3
600
4
1200
5
2400
6
4800
7
9600
8
ERROR MESSAGES
INVALID MFG
ID
The ID entered is incorrect; the valid range is 0 through 960.” 0” is a special case used
to load from the serial port.
INVALID SPACE
The space number or value entered is incorrect. See
EDITING A CUSTOM ID TABLE
for more information.
CODE TOO LONG
The code entered is too long.
SPACE ERROR 10 Space calibration has failed. Check for obstruction. May also be a machine failure.
DEPTH ERROR 11 Depth calibration has failed. Check for obstruction. May also be a machine failure.
INVALID C.F.
Incorrect correction factor. Range is 9 to -9.
NO CODE SET
You must enter both an ID and Code before cutting a key.
OUT OF RANGE
Space or depth calibration value exceeds limits. Range is 127 to -127.
INVALID FLAT #
Incorrect fiat # entered. Range is 1 through 10.
INVALID INSERT #
Incorrect insert # entered. Range is 1 through 4.