Stove and Vent Clearance
Requirements
Minimum Clearances from the Stove
to Combustibles:
See figs. 2-4.
Rear:
2” (51 mm)
Ceiling:
32 1/4” (819 mm)
Corner:
2” (51 mm)
Sides:
3” (76 mm)
Figure 4a. Mantel and Trim Clearance specifications. Back of
bottom plate is flush with the fireplace face. Subtract 2 1/4” with
Short Legs.
Figure 2.
Parallel
Installation
Clearances.
Figure 3.
Corner Clearances.
2”
51 mm
2”
51 mm
3”
(76 mm)
2”
(51 mm)
To Rear Wall
3”
(76 mm)
Alcove Installation
Maximum Alcove Depth: 24” (61 cm)
Minimum Alcove Width: 31 3/4” (80.6 cm)
)Minimum Ceiling Height: 61” (155 cm)
With Short Legs (6”) :
59” (150 cm)
Alcove dimensions result from test configurations,
not stove clearance specifications.
Minimum Clearances from the Vent Pipe to
Combustibles:
Horizontal Run:
Off the top of the pipe 2” (51 mm)
Off the sides and bottom 1” (25 mm)
Vertical Run:
All sides
1” (25 mm)
Figure 4b
Stove is installed with the top plate flush with the fireplace face.
Figure 4c. Stove is installed recessed half-way into fireplace.
Top plate extends 6.5” forward of the fireplace face.
12.5
10.25
8
5.75
Max. Mantel Depth
Min. Mantel
Depth
Max. Trim
Depth = 1
3.5
61.75
156.8 cm
63.25
160.7 cm
64.75
164.5 cm
66.25
168.3 cm
67.75
172.1 cm
6.5
58.75
149.2 cm
29
74.7 cm
12.5
10.25
8
5.75
Max. Mantel Depth
Min. Mantel
Depth
Max. Trim
Depth = 1
3.5
28.5
72.3 cm
53.75
136.5 cm
55.25
140.3 cm
56.75
141.1 cm
58.25
148 cm
52.25
132.7 cm
48.25
122.5 cm