5.  Push in gas control knob slightly and turn clock-

wise             to “OFF”.

  NOTE: Knob cannot be turned from “PILOT” to 

“OFF” unless the knob is pushed in slightly. Do 

not force.

6.  Wait five (5) minutes to clear out any gas. If you 

then smell gas, STOP! Follow “B” in the safety 

information above on this page. If you do not 

smell gas, go to the next step.

1.  Turn ON/OFF switch to” OFF”. The pilot will 

remain lit for normal service.

2.  For complete shutdown, turn ON/OFF switch to 

“OFF”.

FOR YOUR SAFETY, READ BEFORE LIGHTING.

LIGHTING INSTRUCTIONS

TO TURN OFF GAS TO THE APPLIANCE:

LIGHTING INSTRUCTIONS

WARNING:

IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUS-

ING PROPERTY DAMAGE, PERSONAL INJURY, OR LOSS OF LIFE.

A.  This appliance has a pilot which must be lit 

by hand. When lighting the pilot, follow these 

instructions exactly.

B.  BEFORE LIGHTING, smell all around the appli-

ance area for gas. Be sure to smell next to the 

floor because some gas is heavier than air and 

will settle to the floor.

WHAT TO DO IF YOU SMELL GAS:

•  Extinguish any open flame.

•  Open windows.

•   Do not light any appliance.

•  Do not touch any electrical switches.

•  Do not use any phone in your building.

•   Immediately call your gas supplier from a 

neighbor’s phone.

•  If your gas supplier cannot be reached, call the 

fire department.

C.  Use only your hand to push in or turn the gas 

control knob. Never use tools. If the knob will not 

push in or turn by hand, do not try to repair it. 

Call a qualified technician. Force or attempted 

repair may result in a fire or explosion.

D.  Do not use this appliance if any part has been 

under water. Immediately call a qualified service 

technician to inspect the appliance and to re-

place any part of the control system and any gas 

control which has been under water.

1.  STOP! Read the safety information above.
2.  Access the lower controls.

3.   Turn the stove ON/OFF switch to “OFF”, or set the 

thermostat to lowest setting (if used). 

4.  Confirm that the gas supply line shut-off valve is 

open.

Pilot Assembly

7.   Push in gas control knob slightly and turn 

counterclockwise            to “PILOT”.

8.  Push in control knob all the way and hold in. 

Immediately light the pilot by triggering the 

spark ignitor (push the red button repeatedly) 

until pilot lights. Continue to hold the control 

knob in for about one 

minute after the pilot 

lights. Release knob and 

it should spring back. 

The pilot should remain 

lit. If it goes out, repeat 

Steps 5 through 8.

  •  If knob does not 

return when released, 

stop and immediately call your service techni-

cian or gas supplier.

  •  If pilot will not stay lit after several tries, 

turn the control knob to OFF and call your 

service technician or gas supplier.

9.  Turn gas control knob counterclockwise           

to “ON”.

10.Turn the stove ON/OFF switch to “ON”, or set 

thermostat (if used) to desired temperature.

Control 

Knob

OFF

 

PILOT

ON

 

3.  Access the lower controls.

4.  Depress gas control knob slightly and turn clockwise  

             to OFF”.  Do not force.

Control Valve

Содержание Jotul GF 400 DV Sebago

Страница 1: ...r future reference QUEFAIRESIVOUSSENTEZUNEODEURDEGAZ Ne pas tenter d allumer l appareil Ne touchez aucum interrupteur Ne pas vous servir des t l phones se trouvant dans le b timent o vous trouvez Appe...

Страница 2: ...used Installation shall be in strict compliance with the manufacturer s instructions A copy of the installation instructions must remain with the appliance or equipment at the completion of the instal...

Страница 3: ...634 Test Standards This appliance complies with National Safety standards and is tested and listed by Intertek Testing Services of Middleton Wisconsin to ANSI Z21 88 2009 ANSI Z21 88 CSA 2 33 2009 CAN...

Страница 4: ...m input Propane 32 000 BTU hr maximum input 16 000 BTU hr minimum input Inlet Pressure MIN MAX Natural Gas 5 0 WC 1 24 kPa 7 0 WC 1 74 kPa Propane 12 0 WC 2 99 kPa 14 9 WC 3 71 kPa Manifold Pressure M...

Страница 5: ...tion that is not specifi cally addressed in this manual defaults to local code In the absence of local codes the installation require ments must comply with the current National codes In the U S these...

Страница 6: ...adultes doivent tre avertis des dangers des temp ratures de surface lev es et devraient rester l cart pour viter les br lures ou l inflammation des v tements Young children should be supervised while...

Страница 7: ...Alcove dimensions result from test configurations not stove clearance specifications Minimum Clearances from the Vent Pipe to Combustibles Horizontal Run Off the top of the pipe 2 51 mm Off the sides...

Страница 8: ...ig 7 3 Tighten the lock nut and replace the Top Plate Venting Requirements This appliance may be installed with a vertical or horizon tal termination and must conform to the configuration requirements...

Страница 9: ...run at three feet intervals to avoid excessive stress on the offsets Elbows Four 45 or two 90 elbows may be used Do not include the 45 elbow attached to the stove When ever possible use 45 elbows inst...

Страница 10: ...cled letter designations in the vent diagram correspond to the Exhaust Restrictor Setting on the stove First determine which vent termination zone is appropriate for your installation and fuel type th...

Страница 11: ...TICAL TEMINATIONS ONLY SET STOVE EXHAUST RESTRICTOR TO THE POSITION THAT COR RESPONDS TO THE VENT TERMINATION AREA IN THE DIAGRAM ABOVE OPEN AIR INLET RESTRICTOR FOR TERMINATIONS 5 FT AND UNDER SEE FI...

Страница 12: ...the unit and the termination cap A METAL BLOCK OFF PLATE MUST BE CONSTRUCTED AND INSTALLED ABOVE THE UNIT PRIOR TO THE END OF THE INTAKE FLEX AND MUST COMPLETELY SEAL THE CHIMNEY FLUE FROM THE ROOM Co...

Страница 13: ...UL 103 or ULC S 629 listed and have a minimum INSIDE diameter of 6 inch es 150 mm Prefabricated chimneys must be listed for the specific Chimney Conversion Kit you choose Figure 15 Vent System through...

Страница 14: ...NWARD FROM STOVE TO TERMINATION DOWNWARD VENT RUNS TRAP HEAT AND CAUSE HIGH TEMPERATURES TO DEVELOP WITHIN THE VENT THAT COULD START A FIRE Install a Vinyl Siding Standoff between the vent termi natio...

Страница 15: ...ly within 3 feet 90 cm horizontally from the center line of the regulator I Clearance to service regulator vent outlet 3 feet 91 cm minimum J Clearance to nonmechanical air supply inlet to building or...

Страница 16: ...HIBITED BY LOCAL CODES THIS APPLIANCE IS ONLY FOR USE WITH THE TYPE OF GAS THAT IS INDICATED ON THE STOVE S RATING PLATE A GAS CONVERSION KIT IS PROVIDED WITH THE GF 400 SEBAGO DIRECT VENT GAS STOVE C...

Страница 17: ...low replacement of the Burner Plate 10 Replace the Burner Plate Engage the Air Inlet Tube with the Air Shutter and burner orifice Properly seated the burner plate will be engaged at its front corners...

Страница 18: ...d and tighten screws securely 16 Install the identification labels to the stove so that they can be seen by any person that may be servicing the stove Label A apply to back of stove Label B apply to s...

Страница 19: ...ons on the inside back cover of this manual or on the stove s rating plate 3 Brush or spray all joints and connections with the soapy water solution 4 If bubbles appear at any connection or seam or a...

Страница 20: ...to burn natural gas with the air shutter set half open Be aware however that this initial setting may not provide the optimal flame picture in your particular installation No single setting will be ap...

Страница 21: ...Middle Log Figure 37 Install Ember Stones Figure 36 Install Crossover Log PILOT OPENING DO NOT OBSTRUCT The ember stones realistically simulate glow ing coals when the burner is operating These shoul...

Страница 22: ...igure 39 Flame appearance on the high setting after approximately 15 to 20 minutes burning WARNING AIR SHUTTER ADJUSTMENTS SHOULD ONLY BE PER FORMED BY A QUALIFIED PROFESSIONAL SERVICE TECHNICIAN Figu...

Страница 23: ...is vacuum this area frequently Always keep the appliance area clear and free from combustible materials gasoline and other flammable liquids If a vacuum is used during any service on the stove ALWAYS...

Страница 24: ...bled for any reason it should be reassembled and sealed according to the manufac turer s instructions provided at the initial installation Burner and Logset Periodically inspect the Firebox Valve Comp...

Страница 25: ...he Blower Bracket to the stove using the two M6 flange head hex bolts as shown in fig 44 4 Attach the Duct Deflectors using the two 7 x 1 2 screws together with the finger guard mounting screws alread...

Страница 26: ...nually adjusted with the rheostat knob If the burner turns off the blower will be shut off automatically when the stove cools down If automatic blower circulation is not desired place the blower contr...

Страница 27: ...their own against the wall Push them back against the Rear Panel Fig 51 6 Reinstall the Logset See page 21 BE CERTAIN THAT NO EMBERS ARE BLOCKING THE PILOT ASSEMBLY OPENING 7 Replace the Glass Frame...

Страница 28: ...Rev_L 11 16 12 Figure 52 Illustrated Parts Breakdown GF 400 DV Sebago GF 400 DV Sebago Illustrated Parts Breakdown Center mount Valve shown used on models after SN 30000 Side mounted Valve uses same c...

Страница 29: ...mostat 750003 Remote Control 750002 Floor Bracket Kit 750304 Fuel Conversion Kit to Propane 155351 Fuel Conversion Kit to Natural Gas 155352 37 Firebox Assembly 221960 38 Latch Assembly 220091 39 Reli...

Страница 30: ...osts associated with the repair of gas controls plumbing burners log set or sheet metal firebox beyond the warranty period 5 Damage caused by unauthorized modification use or repair 6 Damage to enamel...

Страница 31: ...knob Never use tools If the knob will not push in or turn by hand do not try to repair it Call a qualified technician Force or attempted repair may result in a fire or explosion D Do not use this app...

Страница 32: ...beginning the installation it is important that these instructions be carefully read and understood J tul maintains a policy of continual product development Consequently products may differ in specif...

Отзывы: