Figure 11. Coaxial Vent Termination Window / LP
Figure 12 . Colinear Termination / LP
Vent Termination Zones - Propane
•
VENTING MUST TER
-
MINATE (END) WITHIN
THE SHADED AREA.
• Adjust the Exhaust
Restrictor to position
C
for a straight vertical
colinear termination.
• Adjust the Exhaust
Restrictor to position
D
for a vertical colinear
termination with maxi-
mum 2 ft. offset.
•
VENTING MUST TERMINATE (END) WITHIN ONE OF THE DESIGNAT
-
ED AREAS. ZONE “A” IS FOR VERTICAL TEMINATIONS ONLY.
• SET STOVE EXHAUST RESTRICTOR TO THE POSITION THAT COR-
RESPONDS TO THE VENT TERMINATION AREA IN THE DIAGRAM
ABOVE.
• OPEN AIR INLET RESTRICTOR FOR TERMINATIONS 5 FT AND UNDER.
SEE FIG. 6, PAGE 9.
• ALWAYS MAINTAIN THE PROPER CLEARANCES TO COMBUSTIBLES.
The circled letter designations in the vent diagram correspond
to the Exhaust Restrictor Setting on the stove. First, determine
which vent termination zone is appropriate for your installation
and fuel type, then adjust the stove restrictor plate to the cor
-
responding position as shown in Figure 7, page 9.
Vertical
Termination for
COLINEAR VENT
Horizontal and Vertical
Terminations for COAXIAL VENT