Assembly and installation
5.4
Electrical installation
The ZoneControl is fitted with an internal, non-replaceable fuse that serves exclusively to protect the device.
The protection of the supply cables must be guaranteed by the operator.
The ZoneControl should be fixed to the side of the conveyor on which the RollerDrive cable is located. All of the
connections should be routed to one side of the conveyor to simplify cabling.
The cabling of the PTP connection must always following the direction of the conveyor, that is to say that the PTP
downstream connection of the upstream zone must be connected to the PTP upstream connection of the downstream
zone etc. This also applies if one/several ZoneControl(s) have to be fitted on the other side of the conveyor.
1 Direction of travel
4 Power supply
2 ZoneControl
5 Peer-to-peer connection
3 RollerDrive
6 Package
Required cables: