Electrical installation
IEC / EN 60947
IP54
3x400VAC / 3A
,
24VDC / 2A
In:
www.interroll.com
Germany
–
Hückelhoven
41836
GmbH
Trommelmotoren
Interroll
36/2017
000001234
1112827
Pallet Drive 1
Pallet Drive 1
Modus Hold 1
Status
Error
24VDC
400V
USB
Pallet Drive 2
Pallet Drive 2
Modus Hold 2
Input 1
Pallet Control
for Pallet Drive
400VAC
1
1
2
2
3
1
Connection for Pallet Drives
2
Connection to 400 V AC
3
Housing screw
4
Loosen the hexagon socket screw (3) located in the center to open the housing. An Allen key
size 4 is required.
4
Strip lines appropriately and remove the insulation along the appropriate length of the line.
4
Feed the lines through the provided cable connectors into the device: Size M20 (3 A) /
M25 (10 A) for the 400 V AC supply (2), size M16 (3 A) / M20 (10 A) for the
Pallet Drives (1).
4
Remove unused cable connectors and close the openings with the supplied dummy caps to
ensure protection class IP54.
4
Connect lines as shown in the terminal diagram. The PE conductor must always be connected.
The clamping of the phases must match the labeling on the clamps.
4
Replace the housing and tighten it again. The tightening torque of the screw is 2.8 Nm.
For the Pallet Drive version without integrated brake, the cores 4, 5 and 6 for the star point must
be connected with a suitable connecting terminal.
If the power supply connection uses a 5-pole cable with neutral conductor, it must be routed in
the device in such a way that no contact to any live or conducting component is possible.