International Electronics 212iL Скачать руководство пользователя страница 6

         

6060720  Rev. 1.1

6

q

 

Section 5:  Programming the 212iL

The 212iL supports 120 user codes that will operate the keypad and energize the main relay.  A user
code is stored in the memory of the 212iL with an individual user location, and may be 1 to 6 digits in
length.  Each user code has an associated user location.  To help with the understanding of user
locations, think of them like shelves.  The 212iL has 120 shelves 

(user locations) 

in it, and each user

code gets put into its own shelf 

(user location).

  For example: the Master code, factory defaulted to

1234, is always stored with user location 1.  Every time a new user code is added, the user location
must be advanced by one digit.  To do any programming the 212iL must be put into the Programming
Mode.

Step 1: Entering the Programming Mode.

Programming is accessed by entering the command that tells the 212iL that programming is the
desired function.  The command is always as follows:

99 followed by the # key.
Next the current Master Code has to be entered.
Then finish the command by pressing the * key.
Example:          99 # 1234 *

If the programming command was done successfully, the 212iL will start flashing the yellow LED
slowly, indicating that it is now in the programming mode.  If the yellow does not come on
flashing, that is an indication that the incorrect Master code was entered.  (Validate the Master
code).

Step 2: Changing the Master Code.

 

The 212iL comes with the factory programmed Master code of 1234.  This may be changed to
any code that has 1 to 6 digits in length.  The 212iL also comes set from the factory with a 5
second relay activation time that may be changed to any time from 01 to 99 seconds.

The 212iL has to be in programming mode before you can change the Master code.

      To Change the Master code:

Enter Programming Mode: 99# (Master code) * (Yellow LED flashing slowly).
Next enter user location "1" which is always the Master code’s user number.
Next enter in the new Master code followed by the * key

 (Yellow LED flashes rapidly).

Repeat the new Master code followed by the * key. 

(Yellow LED will flash slowly).

If the change was successful, the yellow LED will still be flashing.

Example: 

1 # 4321 * 4321 *

      To Change the Main Relay Activation Time:

Enter Programming Mode: 99# (Master code) * (Yellow LED flashing slowly).
Next enter the relay activation time in a two digit format "08" for 8 seconds.
Next enter user location "1" which is always the Master code’s user number.
Next enter in the Master code followed by the * key

 (Yellow LED flashes rapidly).

Repeat the Master code followed by the * key. 

(Yellow LED will flash slowly).

If the change was successful, the yellow LED will still be flashing.

Example: 

08 # 1 # 4321 * 4321 *

 To exit the programming mode press the * key.  Or continue for more programming.

Содержание 212iL

Страница 1: ...6060720 Rev 1 1 1 212iL...

Страница 2: ...t Open the box and inside you will find 1 212iL keypad 1 6 Wire conductor harness 2 1 1 4 black socket cap flat head machine screws 2 1 1 4 black Phillips flat head sheet metal screws 1 11 64 Allen wr...

Страница 3: ...at the 212iL is equipped with a Form C Dry contact relay on board This means that there is no voltage running through the relay Until you supply the common leg of the relay with voltage Step 1 Splice...

Страница 4: ...he Electric door strike Step 3 Splice together the Black Negative voltage wire on the 212iL harness negative voltage coming from the power supply to the Negative connection on the Electric door strike...

Страница 5: ...X device Example wiring to an IEI request to exit device part EZ REX If your REX device sends voltage when it is pressed you must connect an external relay to the wires coming from the REX then connec...

Страница 6: ...hat is an indication that the incorrect Master code was entered Validate the Master code Step 2 Changing the Master Code The 212iL comes with the factory programmed Master code of 1234 This may be cha...

Страница 7: ...Master code Next enter the relay time of 00 Next enter the user location 2 3 4 Now enter the new code followed by the key Yellow LED flashes rapidly Repeat the new code followed by the key Yellow LED...

Страница 8: ...followed by the key Next press the key Yellow LED flashes rapidly Next press the key Yellow LED will flash slowly If the change was successful the yellow LED will still be flashing slowly Example 30...

Страница 9: ...h the main relay NOTE 1 Press 00 user location new code repeat code 6 Turn audible keypress feedback ON Press 30 0 1 7 Turn audible keypress feedback OFF Press 30 0 0 8 Turn visual keypress feedback O...

Страница 10: ...for that device If it is over the voltage threshold of 30 VDC you must reduce the output below the threshold Situation 3 The Master code is not allowing access to the programming mode Reason There ar...

Страница 11: ...to IEI s facility freight and insurance charges prepaid after obtaining IEI s Return Merchandise Authorization IEI will not be liable to the purchaser or any one else for incidental or consequential d...