the 212iL is equipped with a Form C, Dry contact relay on board. This means that there is no voltage
running through the relay. (Until you supply the common leg of the relay with voltage).
Step 1:
Splice together the Blue Relay Common wire from the 212iL harness to the Red wire on
the 212iL harness. (Positive voltage coming from the power supply.)
Step 2:
Connect the Brown (Normally Open) wire from the 212iL harness to the Positive voltage
connection on the Electric door strike.
Step 3:
Splice together the Black Negative voltage wire on the 212iL harness (negative voltage
coming from the power supply) to the Negative connection on the Electric door strike.
Shunting a Normally Closed Zone: (see below)
Step 1:
Connect the Blue (Common) Relay wire from the 212iL harness to the Common
connection on the door position switch.
Step 2:
Connect the Brown (Normally Open) Relay wire from the 212iL harness to the Normally
closed connection on the Door position switch.
Electric Strike
(Fail Secure)
Brown (N/O)
Wire
V+
V
-
Blue (C) Wire
V+
V
-
Brown (N/O)
Wire
Blue (Common) Wire
Normally
Closed
Door
Position
Contacts
V+
V
-
To Alarm Panel
To Alarm Panel