6060720  Rev. 1.1

5

Wiring to a Request to Exit (Push to release):

The 212iL keypad may be wired to monitor a remote-switching device, and is meant to be

installed on the secured side of the door.  This is a momentary input that will engage the main relay for
the same amount of time that the master code is programmed with.  This input requires a momentary
closure between the White with a Black trace wire and the Black wire. The only time the REX won't follow
the main relay time is if the Master code has been programmed to latch the main relay.  In this case, the
REX will operate with the default time of 5 seconds.  You may wire in several devices parallel to release
the door from different locations.  

There is no programming required for this option.

Step 1: 

Connect the White with Black trace wire on the 212iL harness to the common connection

on the REX device.

Step 2:

 Splice a wire to the Black (negative) wire on the 212iL harness and connect to the

Normally Open connection on the REX device.

Example wiring to an IEI request to exit device (part # EZ-REX):

If your REX device sends voltage when it is pressed, you must connect an external relay to

the wires coming from the REX, then connect the 212iL REX connections to the common and the
normally open connections on the external relay.

q

 

Section 4:  Power Up

Making the Power Connections: (The 212iL is powered with 12-24 VDC ONLY)

Step 1: 

Connect the Red (Positive voltage input) wire from the 212iL harness to the

positive voltage output connection on the power supply.

Step 2: 

Connect the Black (Negative voltage input) wire from the 212iL harness to the

negative voltage output connection on the power supply.

Upon power up, the 212iL will cycle through the LED's from left to right twice to indicate proper keypad
operation.  (If the LED's continue to flash, refer to the trouble shooting section of this manual).  The
Backlighting will now be on and will dim 15 seconds after the last keypress or 5 seconds after the
programming mode has been exited.  Perform the Self-Test by pressing 7890#123456*.  The LED’s will
cycle from Green to Yellow to Red and then the sounder will beep three times.

White/Black Wire

Black (Negative) Wire

V

-

V+

Содержание 212iL

Страница 1: ...6060720 Rev 1 1 1 212iL...

Страница 2: ...t Open the box and inside you will find 1 212iL keypad 1 6 Wire conductor harness 2 1 1 4 black socket cap flat head machine screws 2 1 1 4 black Phillips flat head sheet metal screws 1 11 64 Allen wr...

Страница 3: ...at the 212iL is equipped with a Form C Dry contact relay on board This means that there is no voltage running through the relay Until you supply the common leg of the relay with voltage Step 1 Splice...

Страница 4: ...he Electric door strike Step 3 Splice together the Black Negative voltage wire on the 212iL harness negative voltage coming from the power supply to the Negative connection on the Electric door strike...

Страница 5: ...X device Example wiring to an IEI request to exit device part EZ REX If your REX device sends voltage when it is pressed you must connect an external relay to the wires coming from the REX then connec...

Страница 6: ...hat is an indication that the incorrect Master code was entered Validate the Master code Step 2 Changing the Master Code The 212iL comes with the factory programmed Master code of 1234 This may be cha...

Страница 7: ...Master code Next enter the relay time of 00 Next enter the user location 2 3 4 Now enter the new code followed by the key Yellow LED flashes rapidly Repeat the new code followed by the key Yellow LED...

Страница 8: ...followed by the key Next press the key Yellow LED flashes rapidly Next press the key Yellow LED will flash slowly If the change was successful the yellow LED will still be flashing slowly Example 30...

Страница 9: ...h the main relay NOTE 1 Press 00 user location new code repeat code 6 Turn audible keypress feedback ON Press 30 0 1 7 Turn audible keypress feedback OFF Press 30 0 0 8 Turn visual keypress feedback O...

Страница 10: ...for that device If it is over the voltage threshold of 30 VDC you must reduce the output below the threshold Situation 3 The Master code is not allowing access to the programming mode Reason There ar...

Страница 11: ...to IEI s facility freight and insurance charges prepaid after obtaining IEI s Return Merchandise Authorization IEI will not be liable to the purchaser or any one else for incidental or consequential d...

Отзывы: