background image

         

6060720  Rev. 1.1

2

212iL (illuminated Luxury) Keypad

Single Unit Keypad- Control Installation Manual

Features:

v

 120 User Capability

v

 Illuminated Backlit Hardened Keys

v

 Programmable 00-99 Second Relay Activation Time

v

 Remote Trigger Input (REX)

v

 Heavy Traffic Application

v

 Flush Mount

v

 Indoor Applications

Installation:

q

 

Section 1:  Unpacking and checking the packing list

q

 

Section 2:  Mounting the 212iL

q

 

Section 3:  Wiring the 212iL

q

 

Section 4:  Power Up

q

 

Section 5:  Programming the 212iL

q

 

Section 6:  Troubleshooting

q

 

Section 1:  Unpacking and checking the packing list

Open the box, and inside you will find:

1

212iL keypad

1 6 Wire conductor harness
2 1 1/4" black, socket cap flat head machine screws
2

1 1/4" black, Phillips flat head sheet metal screws

1 11/64" Allen wrench
1 Installation Manual for 212iL

Please check the contents of this package and verify all components in the packing list are present.

Taking this inventory will familiarize you with the components as well as ensure that you have a
complete parts list.

q

 

 Section 2:  Mounting the 212iL   

(

212iL Dimensions:  3 3/8" x 5 1/8" x 5/8")

1. Select the appropriate location for the 212iL.  Mounting height is the same for an electrical
switch, 48" on center.  

Be sure that the 212iL is mounted indoors ONLY!

International Electronics, Inc.
427 Turnpike Street
Canton, Massachusetts 02021

48"

Содержание 212iL

Страница 1: ...6060720 Rev 1 1 1 212iL...

Страница 2: ...t Open the box and inside you will find 1 212iL keypad 1 6 Wire conductor harness 2 1 1 4 black socket cap flat head machine screws 2 1 1 4 black Phillips flat head sheet metal screws 1 11 64 Allen wr...

Страница 3: ...at the 212iL is equipped with a Form C Dry contact relay on board This means that there is no voltage running through the relay Until you supply the common leg of the relay with voltage Step 1 Splice...

Страница 4: ...he Electric door strike Step 3 Splice together the Black Negative voltage wire on the 212iL harness negative voltage coming from the power supply to the Negative connection on the Electric door strike...

Страница 5: ...X device Example wiring to an IEI request to exit device part EZ REX If your REX device sends voltage when it is pressed you must connect an external relay to the wires coming from the REX then connec...

Страница 6: ...hat is an indication that the incorrect Master code was entered Validate the Master code Step 2 Changing the Master Code The 212iL comes with the factory programmed Master code of 1234 This may be cha...

Страница 7: ...Master code Next enter the relay time of 00 Next enter the user location 2 3 4 Now enter the new code followed by the key Yellow LED flashes rapidly Repeat the new code followed by the key Yellow LED...

Страница 8: ...followed by the key Next press the key Yellow LED flashes rapidly Next press the key Yellow LED will flash slowly If the change was successful the yellow LED will still be flashing slowly Example 30...

Страница 9: ...h the main relay NOTE 1 Press 00 user location new code repeat code 6 Turn audible keypress feedback ON Press 30 0 1 7 Turn audible keypress feedback OFF Press 30 0 0 8 Turn visual keypress feedback O...

Страница 10: ...for that device If it is over the voltage threshold of 30 VDC you must reduce the output below the threshold Situation 3 The Master code is not allowing access to the programming mode Reason There ar...

Страница 11: ...to IEI s facility freight and insurance charges prepaid after obtaining IEI s Return Merchandise Authorization IEI will not be liable to the purchaser or any one else for incidental or consequential d...

Отзывы: