INSTALLATION TIPS & USEFUL
INFORMATION
1. It’s important to review, and install, all the possible
low voltage accessories, (i.e. Firemen Switch,
Remote Control, Freeze Probe), prior to installing
the Multi-purpose Control into an Intermatic control
center. Refer to pages 6 and 7 for further accessory
details.
2. Each section of this installation manual is designed
to be in the proper order of installation. It was
designed this way to make your installation as easy
as possible. Please follow each section carefully.
Only skip sections that do not pertain to your
particular installation.
3. It is important to set the Source Voltage Selector
Jumper to the proper 120 VAC or 240 VAC position.
Failure to set switch in proper position may blow F1
fuse and/or cause damage to circuit board voiding
the manufactures warranty. Please refer to pages 6
and 7 for jumper information.
4. The “ON/OFF” keys are provided for service
operations and for circumstances where
instantaneous response is required. If the intent of
this control is to turn equipment on and off everyday
at the same time, programming individual events for
each circuit will ensure these functions take place.
5. In the case of a power outage, all programmed
events and parameters will stay in memory for 40
years. The time of day will be maintained for a
maximum of 8 hours. If the power outage exceeds
the 8-hour time limit, the clock will reset the time to
12 AM, and continue to implement the programmed
events based on the new time of day. The new time
will blink until changed.
Viewing the Software Revision Level
It may be necessary to view the revision level of
the internal programming for service purposes, or
compatibility issues with future Intermatic Designs. To
do so, simply follow the below procedure:
1. Make sure the Multipurpose Control is not in
programming mode. Press and hold down the
ENTER
key until the display changes.
2. After 5 seconds, the display should change to the
revision level. The
r1
stands for revision one,
r2
for
revision two and so on.
3. Release the
ENTER
key after viewing the revision
level. The revision level should disappear and return
back to the time of day.