19
Defining & Wiring
Each Mode
Mode 1
– (Aux1, Aux2, Aux3) Each of the three single
pole circuits are defined generically, and can control any
load within each of its individual circuit ratings. All three
circuits act independent of each other.
120V or
240V source
120V or
240V load
120V or
240V source
120V or
240V load
120V or
240V load
120V or
240V source
Mode 4
– (Pump High, Pump Low, Cleaner Pump)
Circuit one and two are dedicated single pole outputs for
a two-speed pump load. Circuits one and two will never
be ON at the same time, consistent with a two-speed
pump application. Circuit three is also a dedicated
single pole output for a pressure side cleaner pump.
Circuit three will never come on unless circuit one is on
for at least one minute, consistent with a pressure side
cleaner pump.
22
120V or
240V source
120V or 240V
Two Speed Pump
Common
120V or
240V source
120V or
240V Cleaner
Pump Load
Low
Speed
Line
High
Speed
Line