background image

 

P/N 146626999-

1 (ML) • REV D • ISS 06MAY19 

 

5 / 8 

LED indication 

PIR 

Red LED 

Alarm relay 

To reset 

Start up 

 

Closed 

Automatically after 25 s 

Low voltage 

 

Open (Alarm) 

Apply correct voltage 

PIR intruder 
alarm 

 

Open (Alarm) 

Automatically after 3 s 

 

PIR/AM 

Red 
LED 

Yellow 
LED 

Alarm 
relay 

AM 
relay 

To reset 

Start up 

 

 

Closed 

Closed 

Automatically 
after 60 s  

Low voltage 

 

 

Open 
(Alarm) 

Open 
(Alarm) 

Apply correct 
voltage 

PIR intruder 
alarm 

 

 

Open 
(Alarm) 

 

Automatically 
after 3 s 

Latched PIR 
(Memory) 

 

 

 

 

Switch to Night 
mode 

AM alarm 

 

 

Open* 
(Alarm) 

Open 
(Alarm) 

See DIP 
switch 3 

After AM 
reset 

 

 

 

 

Switch to Night 
mode 

Technical 
fault 

 

 

 

Open 
(Alarm) 

Do a successful 
walk test 

 Continuously on   

 Normal blinking (1 Hz)    

 Fast blinking (4 Hz) 

* Depends on the setting of the DIP switch SW4. 

Specifications 

 

VE1120-D 

VE1120AM-D 

Detector 

PIR 

PIR with AM 

Signal processing 

V2E 

Range 

20 m 

Optical 

11 high-density mirror curtains 

Memory 

Yes 

Input power 

9 to 15 VDC (12 V nominal) 

Peak-to-peak ripple 

2 V (at 12 VDC) 

Detector start-up time 

25 s 

60 s 

Normal current 

6.5 mA 

10 mA 

Current in alarm 

1.2 mA 

3.8 mA 

Maximum current 
(LED on) 

11 mA 

24 mA 

Mounting height 

1.8 to 3.0 m  

(5.9 ft.to 9.8 ft.) 

2.0 to 3.0 m  

(6.6 ft.to 9.8 ft.) 

Target speed range 

30 cm/s to 3 m/s  

(1 ft./s to 10 ft./s) 

20 cm/s to 3 m/s  

(0.65 ft./s to 10 ft./s) 

Alarm (NC) / Tamper 
relay characteristic 

80 mA, 30 VDC, 

resistive 

80 mA, 30 VDC 

Pry-off tamper (not 
evaluated by UL/cUL) 

Optional 

Onboard (yes) 

AM relay characteristic 

— 

80 mA 

at 30 VDC max. 

PIR Alarm time 

3 s 

Operating temperature 
For UL/cUL installations 

−10 to +55°C (14 to 130°F) 

0 to 49°C ( 32 to 120°F ) 

 

VE1120-D 

VE1120AM-D 

Dimensions (H x W x D) 

125 × 55 × 60 mm  

(4.92 x 2.16 x 

2.36 in.) 

125 × 65 × 60 mm  

(4.92 x 2.6 x 2.36 in.) 

Relative humidity 

95% max. noncondensing 

Weight 

150 g 

IP/IK rating 

IP30 IK02 

Regulatory information 

Manufacturer 

PLACED ON THE MARKET BY: 
UTC Fire & Security Americas Corporation, Inc. 
3211 Progress Drive, Lincolnton, NC, 28092, USA 

AUTHORIZED EU REPRESENTATIVE: 
UTC Fire & Security B.V. 
Kelvinstraat 7, 6003 DH Weert, Netherlands 

Product warnings 
and disclaimers 

 

THESE PRODUCTS ARE INTENDED FOR SALE 
TO AND INSTALLATION BY QUALIFIED 
PROFESSIONALS. UTC FIRE & SECURITY 
CANNOT PROVIDE ANY ASSURANCE THAT 
ANY PERSON OR ENTITY BUYING ITS 
PRODUCTS, INCLUDING ANY “AUTHORIZED 
DEALER” OR “AUTHORIZED RESELLER”, IS 
PROPERLY TRAINED OR EXPERIENCED TO 
CORRECTLY INSTALL FIRE AND SECURITY 
RELATED PRODUCTS. 

For more information on warranty disclaimers and 
product safety information, please check 

https://firesecurityproducts.com/policy/product-
warning/

 or scan the QR code. 

Certification 

 

European Union 
directives 

UTC Fire & Security hereby declares that this 
device is in compliance with the applicable 
requirements and provisions of the Directive 
2014/30/EU and/or 2014/35/EU. For more 
information see www.utcfireandsecurity.com or 
www.interlogix.com. 

 

2012/19/EU (WEEE directive): Products marked 
with this symbol cannot be disposed of as 
unsorted municipal waste in the European Union. 
For proper recycling, return this product to your 
local supplier upon the purchase of equivalent 
new equipment, or dispose of it at designated 
collection points. For more information see: 
www.utcfssecurityproducts.eu/recycle/ 

Contact information 

www.utcfireandsecurity.com or www.interlogix.com 

For customer support, see www.utcfssecurityproducts.eu 

Содержание VE1120-D Series

Страница 1: ...stallation Sheet EN DE 1 2 3 4 1 2 3 20 0 m 65 ft 7 in optimum 2 4 m 7 ft 10 in 0 m 2 m 6 ft 6 in 4 m 13 ft 1 in 6 m 19 ft 8 in 8 m 26 ft 2 in 10 m 32 ft 9 in 12 m 39 ft 4 in 20 m range 65 ft 7 in 4 m 2 m 6 ft 6 in 4 m 13 ft 1 in 6 m 19 ft 8 in 8 m 26 ft 2 in 10 m 32 ft 9 in 12 m 39 ft 4 in 1 2 m 3 ft 11 in 4 m 13 ft 1 in ...

Страница 2: ...2 8 P N 146626999 1 ML REV D ISS 06MAY19 5 VE1120 D VE1120AM D J1 Not used J3 and J4 See Figure 7 J6 CV polarity CV polarity 6 J1 J6 J3 J4 J1 J3 J4 J6 ...

Страница 3: ...se screws in positions B or C Figure 3 To install a pry off tamper use position A or C 4 Wire the detector see Figures 3 and 7 5 Select the desired jumper and DIP switch settings see Figure 5 See Jumper settings on page 4 for more information 6 Remove the blinders and add the stickers if required see Figure 6 for an example 7 For ceiling mount applications that require a 90 coverage use the SB01 s...

Страница 4: ...During the Night mode the LEDs are always switched off If a PIR intruder alarm if detected in the Night mode and the detector switches back to Day mode the red LED starts flashing to indicate an alarm in memory The alarm memory is reset by switching the detector to Night mode DIP switch settings Factory default SW 1 When to signal AM anti masking or TF technical fault output On Signals AM or TF on...

Страница 5: ...C 32 to 120 F VE1120 D VE1120AM D Dimensions H x W x D 125 55 60 mm 4 92 x 2 16 x 2 36 in 125 65 60 mm 4 92 x 2 6 x 2 36 in Relative humidity 95 max noncondensing Weight 150 g IP IK rating IP30 IK02 Regulatory information Manufacturer PLACED ON THE MARKET BY UTC Fire Security Americas Corporation Inc 3211 Progress Drive Lincolnton NC 28092 USA AUTHORIZED EU REPRESENTATIVE UTC Fire Security B V Kel...

Страница 6: ...allationen gemäß EN 50131 Sicherheitsstufe 3 nicht Montageposition B Steckbrücken Einstellungen Siehe Abb 5 für die Anordnung der Steckbrücken im Melder J1 Nicht verwendet J3 und J4 Einstellung für Dual Meldegruppe Dient zur Einstellung des Alarm und Sabotagerelais Sie können damit den Melder an eine beliebige Einbruchmeldezentrale anschließen Verwenden Sie die Steckbrücken 3 und 4 Siehe Abb 7 Ver...

Страница 7: ... Technischer Fehler nur auf dem AM Relais EN 50131 Aus Signalisiert AM und TF auf dem AM Relais Werkseinstellung SW 5 Einstellen der LEDs Ein Aktiviert beide LEDs am Melder dauerhaft Werkseinstellung Aus Beide LEDs werden durch den Eingang für Gehtest WT und Tag Nacht D N gesteuert Dies aktiviert die Speicherfunktion des Melders AM Kalibierung Während des Startvorgangs kalibriert sich der AM Schal...

Страница 8: ...RISIERTE HÄNDLER ODER AUTORISIERTE WIEDERVERKÄUFER ÜBER DIE ERFORDERLICHE QUALIFIKATION UND ERFAHRUNG VERFÜGEN UM BRANDSCHUTZ ODER SICHERHEITSTECHNISCHE PRODUKTE ORDNUNGSGEMÄSS ZU INSTALLIEREN Weitere Informationen zu Haftungsausschlüssen sowie zur Produktsicherheit finden Sie unter https firesecurityproducts com policy product warning oder scannen Sie den QR Code Zertifizierung EU Richtlinien UTC...

Отзывы: