214
Direction
Name
IEEE Name
Description
Rx
Access
Challenges
dot1xAuthBackendAcce
ssChallenges
802.1X-based
:
Counts the number of times
that the switch receives the
first request from the backend
server following the first
response from the supplicant.
Indicates that the backend
server has communication
with the switch.
MAC-based
:
Counts all Access Challenges
received from the backend
server for this port (left-most
table) or client (right-most
table).
Rx
Other
Requests
dot1xAuthBackendOther
RequestsToSupplicant
802.1X-based
:
Counts the number of times
that the switch sends an EAP
Request packet following the
first to the supplicant. Indicates
that the backend server chose
an EAP-method.
MAC-based
:
Not applicable.
Rx
Auth.
Successes
dot1xAuthBackendAuth
Successes
802.1X- and MAC-based
:
Counts the number of times
that the switch receives a
success indication. Indicates
that the supplicant/client has
successfully authenticated to
the backend server.
Rx
Auth.
Failures
dot1xAuthBackendAuth
Fails
802.1X- and MAC-based
:
Counts the number of times
that the switch receives a
failure message. This
indicates that the
supplicant/client has not
authenticated to the backend
server.
Tx
Responses
dot1xAuthBackendResp
onses
802.1X-based:
Counts the number of times
that the switch attempts to
send a supplicant's first
response packet to the
backend server. Indicates the
switch is attempting to
communicate with the
backend server. Possible
retransmissions are not
counted.
MAC-based:
Counts all the backend server
packets sent from the switch
towards the backend server for
a given port (left-most table) or
client (right-most table).
Possible retransmissions are
not counted.
Содержание IFS NS3550-24T/4S
Страница 1: ...P N 1072569 REV 00 05 ISS 11OCT12 IFS NS3550 24T 4S User Manual ...
Страница 37: ...User s Manual of NS3550 24T 4S 37 ...
Страница 96: ...96 Figure 4 4 6 Port Mirror Configuration Page Screenshot ...
Страница 127: ...User s Manual of NS3550 24T 4S 127 Figure 4 6 10 Port 1 Port 6 VLAN Configuration ...
Страница 151: ...User s Manual of NS3550 24T 4S 151 Figure 4 8 1 Multicast Service Figure 4 8 2 Multicast Flooding ...
Страница 184: ...184 Figure 4 9 14 Voice VLAN Configuration Page Screenshot ...
Страница 204: ...204 Figure 4 11 4 Network Access Server Configuration Page Screenshot ...
Страница 234: ...234 Figure 4 12 1 Port Limit Control Configuration Overview Page Screenshot ...
Страница 250: ...250 Click to undo any changes made locally and revert to previously saved values ...
Страница 297: ...User s Manual of NS3550 24T 4S 297 ...
Страница 388: ...388 Example Show RADIUS statistics SWITCH security aaa statistics ...
Страница 410: ...410 Parameters vid VLAN ID 1 4095 Default Setting disable ...
Страница 441: ...User s Manual of NS3550 24T 4S 441 Example Enable the mirror mode for port 1 4 SWITCH mirror mode 1 4 enable ...