EN: Installation Sheet 

Description 

GS960 is an acoustic glass break detector giving an alarm 
when glass is smashed at intruder attempts through windows, 
doors and glazed walls.  

The detector is based on advanced microcontroller technology 
and programmed to take a lot of relevant acoustic factors into 
account: the Digital Room Compensation (DRC). This makes 
the detector able to distinguish between a true glass break and 
other irrelevant sounds.  

The detector is for indoor use. The coverage distance is 1 to 
9 m (see Figure 2). The coverage angle is 165

°, which means 

that one detector can protect several windows in the same 
room. The detector can be mounted in the ceiling or on a wall 
with a free 

“line-of-sight” to the window being protected. 

GS960 is certified according to EN 50131-2-7-1:2012, Security 
Grade 2. 

Figure 1: Detector layout 

(1)  Cover lock 
(2)  Base 
(3)  LED 

(4)  Cover 
(5)  Microphone 

Figure 4: Detector base after removal of the cover 

(1)  Cable jacket 

“knock-out” 

(2)  Terminal block 
(3)  Mounting hole 1 
(4)  Cover screw 

(5)  Mounting hole 2 
(6)  Mounting hole 3 
(7)  Slots for assembling the cover 

hooks 

Figure 5: Cover seen from below 

(1)  Cover lock 
(2)  Terminal block pins 
(3)  Tamper switch 

(4)  PC interface 
(5)  DIP switch 
(6)  Hooks holding the cover to the 

base  

Connection to a 24-hour loop 

The detector is constructed for continuous supervision and is 
extra resistant to different acoustic disturbances. It will function 
well in most environments. However in rooms with very high 
rates of disturbances as in industrial workshops and gyms, it is 
recommended to test the detector for 3 to 4 weeks before 
deciding to use it continuously. In rare cases a combination of 
random sounds can trigger an alarm. 

Signalled events 

Detector has a relay and one micro-switch to signal detected 
and processed events to control panel in prioritised order as 
following signals: 

• 

Glass break 

– signalled by INTRUSION relay  

• 

Sabotage 

– signalled independently by TAMPER micro-

switch. 

 

Event 

Signal sent by relay or micro-switch 

 

Intrusion 

 

Tamper 

No stimulus 

Closed 

 

Closed 

Intrusion 

OPEN 

 

Closed 

Tamper 

Closed 

 

OPEN 

Special tools 

In most rooms (for example, offices) no special tools are 
required during the installation. In rooms with complicated 
acoustics it is recommended to use the GS960-TR tester. 
GS960-TR can also be used for function test and annual 
service. 

See also 

“Check the settings with GS960-TR tester” on page 4. 

Opening the detector 

See Figure 3. 

To open the detector, follow these steps: 

1.  Slide the lock cover up (Figure 3, item 1) 

2.  Loosen the screw (item 2) 

3.  Pull cover to open (item 3) 

Mounting instructions 

• 

Detector should be installed on a ceiling or on a wall 
opposite to the glass to be protected. 

ma

x. 

8.5

 m

max. 9 m

min. 0.5 m

min. 0.3 m

min. 

1 m

min. 0.5 m

Содержание GS960

Страница 1: ...ecurity Americas Corporation Inc 1 14 P N 422 6367 ML REV E ISS 03DEC18 GS960 Acoustic Glass Break Detector Installation Sheet EN DE SV 1 2 3 4 5 6 7 1 4 5 2 3 1 2 3 1 2 3 4 5 6 7 6 1 2 5 4 3 ON 1 2 3...

Страница 2: ...Connection to a 24 hour loop The detector is constructed for continuous supervision and is extra resistant to different acoustic disturbances It will function well in most environments However in room...

Страница 3: ...NTRUSION relay output NC 6 Spare Spare contact unconnected 7 Spare Spare contact unconnected 8 Spare Spare contact unconnected 9 Spare Spare contact unconnected 10 TAMPER Tamper switch output C Pin Ma...

Страница 4: ...ED on the detector will start to flicker See Figure 8 4 Go to the furthest distance max 9 m of the glass to be protected and aim the speaker at the detector See Figure 9 The DRC range calculated by th...

Страница 5: ...ting 50 mA 50 V DC peak AC Rs 30 TAMPER contact rating 50 mA 50 V DC peak AC Intrusion fault indication LED Environmental class EN 50130 5 2011 VdS 2110 Class I Operating temp range 5 to 40 C Operatin...

Страница 6: ...tenen zuf lligen Schall Kombinationen eine Falschmeldung generieren Zustandsmeldungen Der Melder Verf gt ber ein Relais und ein Mikroschalter derer Meldungen an die Einbruchmeldezentralen mit folgende...

Страница 7: ...p Schalter Funktionen sind in Tabelle 2 beschreiben Tabelle 2 Dip Schalterfunktionen Dip Funktion Einstellung 1 Alarmrelais Modus EIN Speichermodus AUS Automatikmodus 2 Reichweiteeinstellung 4 9 m Zon...

Страница 8: ...mkompensation verfahren DRC Digital Room Compensation Bereiten Sie den akustischen Glasbruchmelder f r das DRC Verfahren vor in dem Sie den Eingang Klemme D N falls vor handen in den Modus Unscharf sc...

Страница 9: ...5 s Feststellung der Bereichs Einstellung f r Zone 1 4 9 m LED blinkt nach der Kalibrierung langsam 2 mal innerhalb von 2 5 s Feststellung der Bereichs Einstellung f r Zone 2 2 4 m LED blinkt nach de...

Страница 10: ...ad f r att ta h nsyn till en m ngd olika faktorer I rummets akustik DRC Digital Room Compensation Detta g r det m jligt f r detektorn att skilja kta glaskross fr n andra ljud och st rningar Detektorn...

Страница 11: ...glas notera vilken typ av glass det r i det inre glaset Tabell 1 Anslutningspinnar Pin M rkning Funktion 1 Minus 2 Plus 7 till 30 V DC 3 D N Dag och Natt kontroll av LE Pin M rkning Funktion 4 INTRUSI...

Страница 12: ...appen p GS960 TR testaren f r att s tta p str mmen Gr n LED lyser 2 H ll testaren 1 till 3 m fr n detektorn och rikta h gtalaren mot den 3 Tryck en g ng till p START knappen f r att starta DRCl get Ly...

Страница 13: ...9 mA 24 V D N signal niv DAY D N ppen eller 2 5 V NIGHT D N 2 5 V LARM utg ng Rel 50 mA 50 V DC peak AC Rs 30 SABOTAGE kontakt 50 mA 50 V DC peak AC Indikering av Larm FEL LED Milj klass EN 50130 5 20...

Страница 14: ...14 14 P N 422 6367 ML REV E ISS 03DEC18...

Отзывы: