![Interlogix Advent Скачать руководство пользователя страница 81](http://html.mh-extra.com/html/interlogix/advent/advent_installation-instructions-manual_2077278081.webp)
79
Commercial Burglary and Home Navigator System
Appendix B: Reference Tables
Appendix B: Reference Tables
This appendix contains tables for selecting zone type num-
bers, system features, X-10 Module house, unit codes and
responses, SuperBus device unique ID numbers, and text
descriptor numbers. Table notes (if any) appear at the bot-
tom of the last page of the table.
Note
Fire zone types are always active.
Table B1: Zone Type Characteristics
No.
Name
Application
A
c
tiv
e
L
eve
l
Ala
rm
/Sire
n
De
la
y
Supe
rvis
ory
R
e
stor
al
CS Ala
rm
Re
p
o
rt
CS Ca
nc
e
l Re
port
B
y
p
a
ss
ab
le
Chim
e
R
e
se
ts
A
c
tivity
T
imer
00
Fixed Panic
24-hour audible fixed emer-
gency buttons.
1, 2, 3, 4,
5
Police/Police Instant
√
√
√
√
01
Portable Panic
24-hour audible portable emer-
gency buttons.
1, 2, 3, 4,
5
Police/Police Instant
√
√
√
02
Fixed Panic
24-hour silent fixed emergency
buttons.
1, 2, 3, 4,
5
Police/Silent
Instant
√
√
√
√
03
Portable Panic
24-hour silent portable emer-
gency buttons.
1, 2, 3, 4,
5
Police/Silent
Instant
√
√
√
04
Fixed Auxiliary
24-hour auxiliary sensor, such
as Pendant Panic or holdup but-
ton.
1, 2, 3, 4,
5
Aux./ Aux.
Instant
√
√
√
√
05
Fixed Auxiliary
24-hour auxiliary emergency
buttons. Siren shut-off confirms
CS alarm report.
1, 2, 3, 4,
5
Aux./ Aux.
Instant
√
√
√
√
06
Portable Auxil-
iary
24-hour portable auxiliary alert
buttons.
1, 2, 3, 4,
5
Aux./ Aux.
Instant
√
√
√
07
Portable Auxil-
iary
24-hour portable auxiliary but-
ton. Siren shut-off confirms CS
alarm report.
1, 2, 3, 4,
5
Aux./ Aux.
Instant
√
√
√
08
Special Intrusion
Special belongings, such as gun
cabinets and wall safes.
1, 2, 3, 4,
5
Police/Police Instant
√
√
√
√
√
09
Special Intrusion
Special belongings, such as gun
cabinets and wall safes.
1, 2, 3, 4,
5
Police/Police
Standard
√
√
√
√
√
10
Entry/Exit Delay
Entry and exit doors that
require a standard delay time.
2, 3, 4, 5 Police/Police
Standard
√
√
√
√
√
√
√
11
Entry/Exit Delay
Garage doors and entrances
that require an extended delay
time. *
2, 3, 4, 5 Police/Police
Extended
√
√
√
√
√
√
12
Entry/Exit Delay
Driveway gates and entrances
that require a twice extended
delay time. *
2, 3, 4, 5 Police/Police
Twice
Extended
√
√
√
√
√
√
13
Instant Perimeter Exterior doors and windows.
2, 3, 4, 5 Police/Police
Instant
√
√
√
√
√
√
√
14
Instant Interior
Interior doors.
2, 3, 4, 5 Police/Police
Follower
√
√
√
√
√
√
15
Instant Interior
Interior PIR motion sensors. *
2, 3, 4, 5 Police/Police
Follower
√
√
√
√
√
16
Instant Interior
Interior doors.
3, 4, 5
Police/Police
Follower
√
√
√
√
√
√
17
Instant Interior
PIR motion sensors. *
3, 4, 5
Police/Police Follower
√
√
√
√
√
18
Cross Zone
Instant Interior
PIR motion sensors subject to
false alarms. * †
3, 4, 5
Police/Police Follower
√
√
√
√
√
19
Delayed Interior
Interior doors that initiate a
delay before going into alarm.*
3, 4, 5
Police/Police
Standard
√
√
√
√
√
√
Содержание Advent
Страница 104: ......