Commercial Burglary and Home Navigator System
Programming the Panel
I/O Settings
Use the following item numbers to specify how inputs and
outputs behave.
Accessory Modules
The items below allow you to add, delete, list, and modify
SuperBus 2000 devices and settings.
General Input Response Time 1
17006
General Input Response Time 2
17007
General Input Response Time 3
17008
General Input Response Time 4
17009
General Input Response Time 5
17010
General Input Response Time 6
17011
General Input Response Time 7
17118
Defaults = 32 (0.512 Seconds)
Each of the seven onboard (snapcard) inputs has a response time.
The panel has to “see” a transition for at least that length of time
in order to deem it a trip or restoral. At the panel you enter
response times in 16 millisecond increments (actual time = value
x 16 ms).
To Program a General Input Response Time:
1. Enter the desired item number.
2. Enter a response time (8–255) and press #.
Expansion Input Response Time 1
17012
Expansion Input Response Time 2
17013
Expansion Input Response Time 3
17014
Expansion Input Response Time 4
17015
Expansion Input Response Time 5
17016
Expansion Input Response Time 6
17017
Expansion Input Response Time 7
17119
Expansion Input Response Time 8
17120
Defaults = 32 (0.512 Seconds)
Each of the eight expansion inputs has a response time. The panel
has to “see” a transition for at least that length of time in order to
deem it a trip or restoral. At the panel you enter response times in
16 millisecond increments (actual time = value x 16 ms).
To Program an Expansion Input Response Time:
1. Enter the desired item number.
2. Enter a response time (8–255) and press #.
General Purpose I/O 1 Direction
17063
General Purpose I/O 2 Direction
17064
General Purpose I/O 3 Direction
17065
General Purpose I/O 4 Direction
17066
General Purpose I/O 5 Direction
17067
General Purpose I/O 6 Direction
17068
Defaults = 0 (Input)
Select the direction of each general purpose input/output.
To Program General Purpose Input/Output direction:
1. Enter the desired item number.
2. Enter 1 to set the direction as an output, or 0 to set it as an
input. Press # to apply the direction.
Activation Interval One-Shot Time A
17113
(Default = 4 Seconds)
Activation Interval One-Shot Time B
17114
(Default = 30 Seconds)
Activation Interval One-Shot Time C
17115
(Default = 180 Seconds)
Activation Interval One-Shot Time D
17116
(Default = 900 Seconds)
Specify how long (in-seconds) outputs are activated when the
response is set to one-shot.
Note
Only those outputs programmed to be one-shot (A, B, C,
or D) will be affected by this setting.
To Program One-Shot Time:
1. Enter the desired item number.
2. Enter the desired one-shot time duration (1–999) and press #.
Output Delay Time
17112
(Default = 30 Seconds)
Specify how long (in-seconds) output activation is delayed.
Note
Only those outputs that are programmed to be delayed
will be affected by this setting.
To Program the Output Delay Time:
1. Enter the desired item number.
2. Enter the desired delay time (1–999) and press #.
Add (Learn) Bus Devices
48001
Default = NA
Use this item number to force the panel to scan for bus devices
once they have been correctly connected to the panel.
Note
All SuperBus 2000 devices are added to partition/area 1
initially. Use item number 48004 (Bus Device Partition/
Area) to assign devices to different partitions/areas once
added.
To Force the Panel to Scan for Bus Devices:
Once in program mode enter 48001. The display will show
DEVICES
ADDED
, then it will list the added devices as shown.
DEVICE
nn
ID
xxxxxxxx
PARTITION
/
AREA
z
Where
n
is the 2-digit device number (01–62),
xxxxxxxx
is the 8-
digit ID number (address), and
Z
is the partition/area number
(1–8).