Commercial Burglary and Home Navigator System
Installing the System
&$87,21
Connect only the large speaker to panel terminals 9 and
10 as shown. The smaller speaker cannot handle the
output of terminals 9 and 10 and should not be connected
to avoid damaging the speaker.
Figure 18. Connecting the Hardwire Interior Speaker
with Dual Speakers to the Panel
Figure 19. Connecting Multiple Hardwire Interior
Speakers w/Dual Speakers to the Panel
Connecting Listed Sirens
Connect a listed exterior siren for partition/area 1 to the
panel as shown in Figure 20. Interior and exterior sirens for
other partitions/areas must be mapped to SnapCard, Super-
Bus module or panel onboard outputs. Refer to program
item 50005 on page 37.
Figure 20. Connecting the Hardwire Exterior siren to
the Panel (partition/area 1)
Installing an RJ-31X Phone Jack (13-081)
Use the following guidelines when installing an RJ-31X
phone jack for system control by phone and central station
monitoring.
q
Locate the RJ-31X jack (CA-38A in Canada) no further
than five feet from the panel.
q
The panel must be connected to a standard analog (loop-
start) phone line, that provides around 48 volts DC (on-
hook or idle).
Note
The panel cannot be used on a digital or PBX phone line.
These systems are designed for digital type devices only,
operating anywhere from 5 volts DC and up. The panel
uses an analog modem and does not have a digital con-
verter, adapter, or interface to operate through such sys-
tems.
q
For full line seizure, install an RJ-31X phone jack on the
premises phone line so the panel is ahead of all phones
and other devices on the line. This allows the panel to
take control of the phone line when an alarm occurs,
even if the phone is in use or off-hook.
q
If an analog line is not available, contact your cus-
tomer’s telecommunications specialist and tell him/her
you need an analog line off the phone switch (PBX
mainframe) or a 1FB (standard business line).
Note
Connecting the panel to an analog line off the phone
switch places the panel ahead of the phone system, pre-
venting panel access from phones on the premises.
However, the panel can still be accessed from off-site
phones.
To connect a phone line to the panel using an
RJ-31X/CA-38A jack:
1. Run a 4-conductor cable from the TELCO protector
block to the jack location (see Figure 21).
2. Connect one end of the cable to the jack.
3. At the TELCO protector block, remove the premises
phone lines (lines from phone jacks on premises) from
the block and splice them to the black and white (or yel-
low) wires of the 4-conductor cable.
4. Connect the green and red wires from the 4-conductor
cable to the A (+) and B (-) posts on the block (see Fig-
ure 21).
8 5 4 3 G 3 3 A . D S 4
H A R D W I R E I N T E R I O R S I R E N
D U A L S P E A K E R
6 0 - 5 2 8
9
1 0
V O I C E
S I R E N
V O I C E
S I R E N
P A N E L T E R M I N A L S
D E T
A I L
2 2 0 M F , 3 5 V
C A P A C I T O R
( N O N - P O L A R I Z E D )
1 7 - 1 0 1
( L O C A T E A T
D E V I C E )
2 . 0 K O H M
E O L R E S I S T O R
4 9 - 4 6 7
( L O C A T E A T
L A S T D E V I C E )
8 5 4 3 2 7 5 B . . D S F
V O I C E
S I R E N
V O I C E
S I R E N
P A N E L T E R M I N A L S
D E T A I L
9
1 0
2 2 0 M F , 3 5 V
C A P A C I T O R
( N O N - P O L A R I Z E D )
1 7 - 1 0 1
( L O C A T E A T
D E V I C E )
2 . 0 K O H M
E O L R E S I S T O R
4 9 - 4 6 7
( L O C A T E A T
L A S T D E V I C E )
8543139B.DSF
4
5
6
7
8
INT.
BELL
RTN
+12
VDC
OUT
HARDWIRE
EXTERIOR SIREN
RED
BLACK
PANEL TERMINALS
EXT. SIREN/HORN
IN
FOR SUPPLEMENTARY USE ONLY