Commercial Burglary and Home Navigator System
Programming the Panel
Reporting Settings
Non X-10 Output 1 (menu output 33)
xx049
Non X-10 Output 2 (menu output 34)
xx050
Non X-10 Output 3 (menu output 35)
xx051
Non X-10 Output 4 (menu output 36)
xx052
Non X-10 Output 5 (menu output 37)
xx053
Non X-10 Output 6 (menu output 38)
xx054
Non X-10 Output 7 (menu output 39)
xx055
Non X-10 Output 8 (menu output 40)
xx056
Default = 0 (None)
There are 40 menu outputs per partition/area. The first 32 are X-
10 outputs, the last 8 are non X-10 outputs. All X-10 outputs
(menu outputs 1-32) are automatically linked to X-10 devices.
Non X-10 outputs (menu outputs 33-40) must be linked to a pro-
grammable output in order to control a light or device.
Note
All menu outputs must be programmed (learned) into the
panel before they will function. See “Programmable Out-
put Settings” on page 36 for more information.
Linking Non X-10 Outputs:
1. Enter the item number for the desired non X-10 output.
2. Enter the desired programmable output number (1–100), then
press # to confirm the selection.
Light Access Code Enable
xx069
Default = 0 (Off)
If on, users must enter a valid access code before controlling
lights. If off, an access code is not required for light control.
Turning Light Access Code On/Off:
Once the item number has been entered, enter 1 for on (access
code required), or 0 for off. Press # to apply the new setting.
Device Access Code Enable
xx070
Default = 0 (Off)
If on, users must enter a valid access code before controlling
devices. If off, an access code is not required for device control.
Turning Device Access Code On/Off:
Once the item number has been entered, enter 1 for on (access
code required) or 0 for off. Press # to apply the new setting.
Latchkey Access Code Enable
xx071
Default = 0 (Off)
If on, users must enter a valid access code before accessing the
Latchkey setting. If off, an access code is not required to access
the Latchkey setting. For more information on Latchkey, please
see the User’s Manual.
Turning Latchkey Access Code On/Off:
Once the item number has been entered, enter 1 for on (access
code required) or 0 for off. Press # to apply the new setting.
Report Partition/Area Events
xx088
Default = 1 (On)
If on, the panel will report partition/area events to the central sta-
tion.
Turning Partition/Area Event Reporting On/Off:
Once the item number has been entered, enter 1 to turn partition/
area event reporting on or 0 turn reporting off. Press # to apply the
new setting.
Cancel Event Cancels Report
xx089
Default = 1 (On)
If on, the panel will cancel the sending of an alarm report (to cen-
tral station) if the event is canceled before the alarm reporting
delay (xx013, xx012, or xx014) expires.
Turning Cancel Event Cancels Report On/Off:
Once the item number has been entered, enter 1 to turn the setting
on (canceled event cancels report) or 0 to turn it off. Press # to
apply the new setting.
Print Partition/Area Events
xx091
Default = 1 (On)
If on, the panel will print partition/area events on a local printer.
To Print Partition/Area Events:
Once the item number has been entered, enter 1 (on) to enable
printing of partition/area events or 0 (off) to disable printing of
partition/area events. Press # to apply the new setting.
Panic Report Delay
xx012
Default = 05 Seconds
This setting allows you to specify the length of time (in seconds)
between the time a panic alarm condition is detected, and a panic
report is sent to the central station. This allows users time to can-
cel the report of a false alarm if setting xx089 is on.
Specifying the Panic Report Delay:
Once the item number has been entered, enter the number of sec-
onds (1–120) you wish the panel to wait before sending a panic
report. Press # to apply the new setting.
Alarm Report Delay
xx013
Default = 05 Seconds
This setting allows you to specify the length of time (in seconds)
between the time a non-panic and non-fire alarm condition is
detected, and a report is sent to the central station. This allows
users time to cancel the report of a false alarm if setting xx089 is
on.
Specifying the Alarm Report Delay:
Once the item number has been entered, enter the number of sec-
onds (1–120) you wish the panel to wait before sending a report.
Press # to apply the new setting.