Electrical Wiring 

 

i

 

This chapter shows the electrical wiring for connecting slave terminals, sensors and electrical devices.

 

 

 

There is a danger of electric shock in case of faulty 230VAC installations.  
Severe injuries, or in worst case even death, can result. 

 

Installation of 230V systems as well as Schuko sockets may only be carried out by 
electricians or other qualified persons.  

 

 

NOTE

 

For secure, reliable operation, the following must be observed: 

 

Our specified cable lengths. The specifications indicate the permitted cable lengths that 
guarantee reliable system function. 

 

Our specified cable type. Install only data and control cables with cable shielding, e.g. 
cable type JY(ST)Y with anti-static shield. 

 

Electrical installation standards. The terminal controller may only be operated via electrical 
systems that comply with current national standards, e.g. DIN VDE 0100.  

 

Separator in compliance with EN 600950-1. Install an easily accessible Schuko socket with 
its own fuse in the vicinity of the terminal controller.  

 

An even distribution of the slave terminals among the 3 BUS interfaces. Without changing 
the default interface settings, you can connect up to six slave terminals to BUS 1, up to four 
slave terminals to BUS 2 and up to six slave terminals to BUS 3. Always connect a slave 
terminal with address 1 to BUS 1. 

 

3

3

3

8x input

  8x REL Out
up tu 30V 2A

2

3a

4

5

1

2

2

2

Ethernet 

RS 485 BUS 3

RS 485 BUS 2

RS 485 BUS 1

6

RS 232
RS 485

1m

=RJ 45 wiring box

 

 

Figure 4: Electrical Wiring  
No. 

 

Cable Length  Recommended Cable Type 

Power cable with Schuko plug (not needed with PoE supply)   

 

RJ45 patch cable, shield braiding recommended 

5m 

CAT 3 or higher 

RS485 BUS data lines with up to 8 slave terminals  

1200m 

J-Y(ST) Y 4x 2x 0,6 mm 

2

 

3a 

RS485 branch cable from slave terminal to BUS cable  

100m 

J-Y(ST) Y 4x 2x 0,6 mm 

2

 

Control cable  

Not specified 

J-Y(ST) Y 4x 2x 0,6 mm 

2

 

Connection cable to floating sensors 

100m 

J-Y(ST) Y 4x 2x 0,6 mm 

2

 

6  

Alternative PC connections with RS232 or RS485 

25 / 1,000 m 

J-Y(ST) Y 4x 2x 0,6 mm 

2

 

 
 
 

Содержание IF-4070

Страница 1: ...Installation and Connection Instructions for IF 4070 Terminal Controller 95 10263_Terminal Controller IF 4070 Version 1 16 2013...

Страница 2: ...o severe injuries or even death from electric shock Intended Use Terminal controllers are intended for controlling Interflex slave terminals managed by Interflex software Any other use is not in accor...

Страница 3: ...3 Initial Operation 14 Procedure 14 Point 1 Switch On Power Supply 14 Point 2 Cold Boot 14 Point 3 Establish a TELNET Connection 15 Point 4 Configure the Network Connections 16 Point 5 Set the Paramet...

Страница 4: ...slave terminals 8 x output up to30V2A 2 1a 1b 5 6 7 4 3 1 Power either 230 VAC 18 30VAC or PoE HuB or PoE device Class 3 Interflex IF 6020 or IF 6040 Ethernet w o PoE Figure 1 Interflex T A Access Con...

Страница 5: ...ays Seven LEDs indicate the controller operating statuses LEDs LED status User information Bus 1 Lights up 1 Data exchange with slave terminal on BUS 1 Bus 2 Lights up 1 Data exchange with slave termi...

Страница 6: ...d to the sides for mounting into 19 rack systems Danger of electric shock People can be seriously hurt or killed through physical contact with 230 volt electricity Unplug the Schuko plug prior to open...

Страница 7: ...ousing brackets included in the delivery can be used for mounting the controller into 19 modules or screw fastening to a wall Without angle brackets the terminal controller can be placed on a tabletop...

Страница 8: ...Install an easily accessible Schuko socket with its own fuse in the vicinity of the terminal controller An even distribution of the slave terminals among the 3 BUS interfaces Without changing the defa...

Страница 9: ...is not allowed because this can lead to malfunctions in connection with PoE devices If this type of operation is nonetheless required an additional low voltage power supply with 18VDC 1A must be used...

Страница 10: ...Serial PC Ports An RS232 connection can be used as an alternative to a network connection An RS485 connection can also be realized with a convertor on the PC side i Please note The serial interface i...

Страница 11: ...via the RJ45 female connectors Use therefore only shielded cables and shielded connection components like HiRose male connectors etc Figure 7 Connection of bus data cables with RJ45 plugs Bus 1 2 3 1...

Страница 12: ...strip KL 3 9 8 10 11 12 13 14 Sh IN 1 GND IN 2 GND S 1 S 2 cable length up tu100 m sensor connection sensor frequenz up to 20 Hz Terminals for floating sensors Terminal strip KL 3 Terminal strip KL 4...

Страница 13: ...interface settings The following interface settings apply for a RS232 service connection Baud rate 115200 Data bits 8 data bit no parity 1 stop bit Flow control None Figure 9 Front RS232 service conne...

Страница 14: ...the slave terminals You will find further information on steps 1 to 9 in the following Point 1 Switch On Power Supply After the operating voltage is switched on the terminal controller 1 boots the Li...

Страница 15: ...he following input syntax must be observed Commands are written with small letters Options are separated from the command by a blank space bar and a minus sign The command displays an overview of poss...

Страница 16: ...BUS 3 Change the values if there is a different allocation You can modify the booking memory under Number of bookings The default value is 50 This value is sufficient for storing 50 000 bookings If yo...

Страница 17: ...lists a second reader e g FIP for Fingerprint In Out Column In Out lists a parameterized RS232 interface e g RKASS for a cashbox I O This column lists the I O boards of the slave terminals Slave term...

Страница 18: ...take up to 30 seconds until the RUN LED lights up again NOTE Set the Kaltst cold boot switch SW switch back to the up position after the RUN LED lights up If the switches remain in the down position...

Страница 19: ...0 baud Inputs 8 input contacts for floating sensors Debounce time of contacts at least 100 ms Output relay switching power 8 relays with normally closed NC and normally open NO contacts 30 V 2 A maxim...

Отзывы: