Cover Picture: IF-4070 Terminal Controller 
 

Scope of Delivery 

The following is included in the delivery: 

 

Terminal controller 

 

Two housing L-brackets for mounting into 19" module 

 

Two brackets for clipping into 19" module 

 

Accessory bag with materials for fastening and rubber feet for placement on tables 

 

 

  Please check the goods for completeness upon receipt. 

 

Validity of the Documentation 

This documentation is valid for terminal controllers of the series IF-4070 with software as of version 7.12.3.  
It contains information on installation, connection and initial operation. For translation reasons, the annotation texts 
in the figures are in English. 

 

Notes on Installation and Wiring 

 

This documentation is intended for use by authorized persons trained in electrical engineering who are 
responsible for installing and starting up the terminal controller.  

 

Additional information (e.g. notes) is framed and marked with 

i

 

Important information is indicated by this symbol 

NOTE

 and must be observed. 

Damage can result otherwise.  
 

Safety-relevant information and instructions 

are indicated by the 

 

symbol. Please follow the 

instructions. Noncompliance may lead to severe injuries or even death from electric shock.

  

 

Intended Use

 

Terminal controllers are intended for controlling Interflex slave terminals managed by Interflex software. Any other 
use is not in accordance with the intended purpose and is therefore not permitted.  

 

Storage 

Store the terminal controller in a dry place. Before storing devices with optional built-in emergency power supply, 
you must set the accumulator switch on the front side to the OFF position. 

 

Disposal  

 

Once its service life ends, the device must be disposed of properly as electronic waste. The owner can 
dispose of the device himself or return it to the manufacturer. 
 

 

i

 

The terminal controller

 complies with European standards valid at the time of printing. Modifications 

to the device are not permitted.  

All technical information 

herein is accurate at the time of printing. It is, however, not to be deemed in 

any way to be a specific warranty of certain characteristics. 

The product brand names and trademarks

 specified in this documentation are protected by 

commercial and patent laws. 

 

Interflex Datensysteme GmbH & Co. KG 
Ingersoll Rand Security Technologies EMEIA 

 

Grosswiesenstrasse 24 
D-78591 Durchhausen, Germany 
Tel. + 49 7464 382-0 
E-mail: [email protected] 
 
Should there be any further questions, please contact your Interflex office. 
Copyright Interflex Datensysteme GmbH 2013

 

 

Содержание IF-4070

Страница 1: ...Installation and Connection Instructions for IF 4070 Terminal Controller 95 10263_Terminal Controller IF 4070 Version 1 16 2013...

Страница 2: ...o severe injuries or even death from electric shock Intended Use Terminal controllers are intended for controlling Interflex slave terminals managed by Interflex software Any other use is not in accor...

Страница 3: ...3 Initial Operation 14 Procedure 14 Point 1 Switch On Power Supply 14 Point 2 Cold Boot 14 Point 3 Establish a TELNET Connection 15 Point 4 Configure the Network Connections 16 Point 5 Set the Paramet...

Страница 4: ...slave terminals 8 x output up to30V2A 2 1a 1b 5 6 7 4 3 1 Power either 230 VAC 18 30VAC or PoE HuB or PoE device Class 3 Interflex IF 6020 or IF 6040 Ethernet w o PoE Figure 1 Interflex T A Access Con...

Страница 5: ...ays Seven LEDs indicate the controller operating statuses LEDs LED status User information Bus 1 Lights up 1 Data exchange with slave terminal on BUS 1 Bus 2 Lights up 1 Data exchange with slave termi...

Страница 6: ...d to the sides for mounting into 19 rack systems Danger of electric shock People can be seriously hurt or killed through physical contact with 230 volt electricity Unplug the Schuko plug prior to open...

Страница 7: ...ousing brackets included in the delivery can be used for mounting the controller into 19 modules or screw fastening to a wall Without angle brackets the terminal controller can be placed on a tabletop...

Страница 8: ...Install an easily accessible Schuko socket with its own fuse in the vicinity of the terminal controller An even distribution of the slave terminals among the 3 BUS interfaces Without changing the defa...

Страница 9: ...is not allowed because this can lead to malfunctions in connection with PoE devices If this type of operation is nonetheless required an additional low voltage power supply with 18VDC 1A must be used...

Страница 10: ...Serial PC Ports An RS232 connection can be used as an alternative to a network connection An RS485 connection can also be realized with a convertor on the PC side i Please note The serial interface i...

Страница 11: ...via the RJ45 female connectors Use therefore only shielded cables and shielded connection components like HiRose male connectors etc Figure 7 Connection of bus data cables with RJ45 plugs Bus 1 2 3 1...

Страница 12: ...strip KL 3 9 8 10 11 12 13 14 Sh IN 1 GND IN 2 GND S 1 S 2 cable length up tu100 m sensor connection sensor frequenz up to 20 Hz Terminals for floating sensors Terminal strip KL 3 Terminal strip KL 4...

Страница 13: ...interface settings The following interface settings apply for a RS232 service connection Baud rate 115200 Data bits 8 data bit no parity 1 stop bit Flow control None Figure 9 Front RS232 service conne...

Страница 14: ...the slave terminals You will find further information on steps 1 to 9 in the following Point 1 Switch On Power Supply After the operating voltage is switched on the terminal controller 1 boots the Li...

Страница 15: ...he following input syntax must be observed Commands are written with small letters Options are separated from the command by a blank space bar and a minus sign The command displays an overview of poss...

Страница 16: ...BUS 3 Change the values if there is a different allocation You can modify the booking memory under Number of bookings The default value is 50 This value is sufficient for storing 50 000 bookings If yo...

Страница 17: ...lists a second reader e g FIP for Fingerprint In Out Column In Out lists a parameterized RS232 interface e g RKASS for a cashbox I O This column lists the I O boards of the slave terminals Slave term...

Страница 18: ...take up to 30 seconds until the RUN LED lights up again NOTE Set the Kaltst cold boot switch SW switch back to the up position after the RUN LED lights up If the switches remain in the down position...

Страница 19: ...0 baud Inputs 8 input contacts for floating sensors Debounce time of contacts at least 100 ms Output relay switching power 8 relays with normally closed NC and normally open NO contacts 30 V 2 A maxim...

Отзывы: