Function  

i

 

This chapter provides information on device functions, switches, and power supply. 

 

 

The terminal controller is designed:  

 

for operation with the Interflex software IF-6010, IF-6020 or IF-6040.  

 

to control up to 16 slave terminals. 

 

to save IN, OUT, absence reason as well as access time stamps (times) as well as events from slave 
terminals.  

 

for offline operation. The terminal controller takes over functions of the Interflex software during offline 
operation, e.g., it checks and acknowledges booking authorizations when identification is performed on a slave 
terminal.  

 

to control external devices. Eight relays switch electrical devices up to 3V/ 2A, e.g. electric door openers or the 
inputs of alarm systems. Relay functions and switching times can be parameterized via the Interflex software  

 

to record sensor statuses. Eight inputs record the switching actions of floating feedback sensors. The sensors 
can be configured as indicators or counting contacts

1

 via the Interflex software.  

 

IN1-8

REL 1-8

RS 485 BUS cable

RS 485 BUS cable

RS 485 BUS cable

8 x input

IF- 4070

up to 16 slave terminals

8 x output

up to 30 V 2A

 

2

1a

1b

5

6

7

4

3

1

Power

either

 230 VAC/18-30VAC 

or 

PoE

HuB or
PoE device
Class 3

Interflex
IF-6020 or
IF-6040

Ethernet w/o PoE

 

 

Figure 1: Interflex T&A/ Access Control System  

IF-4070 terminal controller 

BUS data line for 8 slave terminals 

1a 

8 inputs for floating sensors 

Slave terminals for recording time data 

1b 

Relay (30 V, 2A switching power of the relay 
contacts) 

Slave terminals for access control 

Host with IF-6020/ IF-6040 software  

Locking device with access point actuator and 
sensor 

Data line to host PC, e.g. Ethernet or RS232 

 

 

 

Interfaces 

The terminal controller is equipped with the following "interfaces": 

 

Ethernet 10/100 Base T for connection to a host PC with Interflex software 

 

Ethernet service interface for TELNET or SSH connections 

 

1x RS232 host interface as alternative to Ethernet connection 

 

1x RS232 host interface as alternative to Ethernet connection 

 

1x RS485 host interface as alternative to Ethernet connection 

 

3x RS485 BUS interfaces for connection of 16 slave terminals.  
Up to 8 slave terminals can be connected and operated on each interface. 

 

8 inputs for connection of floating indicators or counting contacts up to 20 Hz 

 

8 relays with NO/NC contacts and a switching power of 30V 2A 

 

                                                   

1

 

Up to max. 20 Hz

 

Содержание IF-4070

Страница 1: ...Installation and Connection Instructions for IF 4070 Terminal Controller 95 10263_Terminal Controller IF 4070 Version 1 16 2013...

Страница 2: ...o severe injuries or even death from electric shock Intended Use Terminal controllers are intended for controlling Interflex slave terminals managed by Interflex software Any other use is not in accor...

Страница 3: ...3 Initial Operation 14 Procedure 14 Point 1 Switch On Power Supply 14 Point 2 Cold Boot 14 Point 3 Establish a TELNET Connection 15 Point 4 Configure the Network Connections 16 Point 5 Set the Paramet...

Страница 4: ...slave terminals 8 x output up to30V2A 2 1a 1b 5 6 7 4 3 1 Power either 230 VAC 18 30VAC or PoE HuB or PoE device Class 3 Interflex IF 6020 or IF 6040 Ethernet w o PoE Figure 1 Interflex T A Access Con...

Страница 5: ...ays Seven LEDs indicate the controller operating statuses LEDs LED status User information Bus 1 Lights up 1 Data exchange with slave terminal on BUS 1 Bus 2 Lights up 1 Data exchange with slave termi...

Страница 6: ...d to the sides for mounting into 19 rack systems Danger of electric shock People can be seriously hurt or killed through physical contact with 230 volt electricity Unplug the Schuko plug prior to open...

Страница 7: ...ousing brackets included in the delivery can be used for mounting the controller into 19 modules or screw fastening to a wall Without angle brackets the terminal controller can be placed on a tabletop...

Страница 8: ...Install an easily accessible Schuko socket with its own fuse in the vicinity of the terminal controller An even distribution of the slave terminals among the 3 BUS interfaces Without changing the defa...

Страница 9: ...is not allowed because this can lead to malfunctions in connection with PoE devices If this type of operation is nonetheless required an additional low voltage power supply with 18VDC 1A must be used...

Страница 10: ...Serial PC Ports An RS232 connection can be used as an alternative to a network connection An RS485 connection can also be realized with a convertor on the PC side i Please note The serial interface i...

Страница 11: ...via the RJ45 female connectors Use therefore only shielded cables and shielded connection components like HiRose male connectors etc Figure 7 Connection of bus data cables with RJ45 plugs Bus 1 2 3 1...

Страница 12: ...strip KL 3 9 8 10 11 12 13 14 Sh IN 1 GND IN 2 GND S 1 S 2 cable length up tu100 m sensor connection sensor frequenz up to 20 Hz Terminals for floating sensors Terminal strip KL 3 Terminal strip KL 4...

Страница 13: ...interface settings The following interface settings apply for a RS232 service connection Baud rate 115200 Data bits 8 data bit no parity 1 stop bit Flow control None Figure 9 Front RS232 service conne...

Страница 14: ...the slave terminals You will find further information on steps 1 to 9 in the following Point 1 Switch On Power Supply After the operating voltage is switched on the terminal controller 1 boots the Li...

Страница 15: ...he following input syntax must be observed Commands are written with small letters Options are separated from the command by a blank space bar and a minus sign The command displays an overview of poss...

Страница 16: ...BUS 3 Change the values if there is a different allocation You can modify the booking memory under Number of bookings The default value is 50 This value is sufficient for storing 50 000 bookings If yo...

Страница 17: ...lists a second reader e g FIP for Fingerprint In Out Column In Out lists a parameterized RS232 interface e g RKASS for a cashbox I O This column lists the I O boards of the slave terminals Slave term...

Страница 18: ...take up to 30 seconds until the RUN LED lights up again NOTE Set the Kaltst cold boot switch SW switch back to the up position after the RUN LED lights up If the switches remain in the down position...

Страница 19: ...0 baud Inputs 8 input contacts for floating sensors Debounce time of contacts at least 100 ms Output relay switching power 8 relays with normally closed NC and normally open NO contacts 30 V 2 A maxim...

Отзывы: