9330 Operating Manual 

 

 

 

Interface Inc. 

● 7401 East Butherus Drive, Scottsdale, Arizona 85260 USA ● Phone 480.948.5555 ● Fax 480.948.1924 

www.interfaceforce.com 

● Email: 

[email protected] 

● 

800.947.5598 

 

Document Number 15-216 Rev B 

Page 67 of 74

 

9.  TEDS 

– Transducer Electronic Data Sheet 

 

10. Strain gage 

 

F

IGURE 

86

 

-

 

S

TRAIN 

G

AGE

 

11. Calibrate 

 

F

IGURE 

87

 

-

 

C

ALIBRATE

 

Содержание BlueDAQ 9330

Страница 1: ...01 East Butherus Drive Scottsdale Arizona 85260 USA Phone 480 948 5555 Fax 480 948 1924 www interfaceforce com Email contact interfaceforce com 800 947 5598 Document Number 15 216 Rev B Page 1 of 74 1...

Страница 2: ...tery life 300 hour standby Stores up to 6 sensor calibrations Powers up to 4x 350 ohm sensors 7 digit display Description Model 9330 is a bipolar display logging amplifier that can be used in portable...

Страница 3: ...n and Commissioning 8 Menu Options 9 Sensor Config 10 Logger Config 11 Options 11 Data Acquisition 12 Set Scaling 12 Save Settings 13 Load Settings 13 Strain Analysis 14 Logger Menu 15 Measuring Ampli...

Страница 4: ...rive Scottsdale Arizona 85260 USA Phone 480 948 5555 Fax 480 948 1924 www interfaceforce com Email contact interfaceforce com 800 947 5598 Document Number 15 216 Rev B Page 4 of 74 File 34 View 39 Act...

Страница 5: ...ual Interface Inc 7401 East Butherus Drive Scottsdale Arizona 85260 USA Phone 480 948 5555 Fax 480 948 1924 www interfaceforce com Email contact interfaceforce com 800 947 5598 Document Number 15 216...

Страница 6: ...ace Inc 7401 East Butherus Drive Scottsdale Arizona 85260 USA Phone 480 948 5555 Fax 480 948 1924 www interfaceforce com Email contact interfaceforce com 800 947 5598 Document Number 15 216 Rev B Page...

Страница 7: ...utherus Drive Scottsdale Arizona 85260 USA Phone 480 948 5555 Fax 480 948 1924 www interfaceforce com Email contact interfaceforce com 800 947 5598 Document Number 15 216 Rev B Page 7 of 74 Note Refer...

Страница 8: ...Pin Assignment Connection and Commissioning To switch on press the MODE button until the display is illuminated The device contains a battery that is charged by connecting the power adapter supplied...

Страница 9: ...erface Inc 7401 East Butherus Drive Scottsdale Arizona 85260 USA Phone 480 948 5555 Fax 480 948 1924 www interfaceforce com Email contact interfaceforce com 800 947 5598 Document Number 15 216 Rev B P...

Страница 10: ...rface Inc 7401 East Butherus Drive Scottsdale Arizona 85260 USA Phone 480 948 5555 Fax 480 948 1924 www interfaceforce com Email contact interfaceforce com 800 947 5598 Document Number 15 216 Rev B Pa...

Страница 11: ...e Inc 7401 East Butherus Drive Scottsdale Arizona 85260 USA Phone 480 948 5555 Fax 480 948 1924 www interfaceforce com Email contact interfaceforce com 800 947 5598 Document Number 15 216 Rev B Page 1...

Страница 12: ...nc 7401 East Butherus Drive Scottsdale Arizona 85260 USA Phone 480 948 5555 Fax 480 948 1924 www interfaceforce com Email contact interfaceforce com 800 947 5598 Document Number 15 216 Rev B Page 12 o...

Страница 13: ...nc 7401 East Butherus Drive Scottsdale Arizona 85260 USA Phone 480 948 5555 Fax 480 948 1924 www interfaceforce com Email contact interfaceforce com 800 947 5598 Document Number 15 216 Rev B Page 13 o...

Страница 14: ...face Inc 7401 East Butherus Drive Scottsdale Arizona 85260 USA Phone 480 948 5555 Fax 480 948 1924 www interfaceforce com Email contact interfaceforce com 800 947 5598 Document Number 15 216 Rev B Pag...

Страница 15: ...recording of measured data on the SD card Set Log OFF No Recording Set Log onOK Recording of measured data on the SD card as long as the OK button at measured value displayed is pressed USBmode Comm...

Страница 16: ...es SetMode MaxMin The maximum minimum or mean value can be displayed in the display and all three are recorded to file Menu Entry Level 1 Menu Entry Level 2 Menu Entry Level 3 Menu Entry Level 4 Loggi...

Страница 17: ...etting of the physical nominal value of the sensor Rated output Numeric setting of the electrical characteristic value of the sensor Strain analysis Set gage factor Numeric setting of the K factor bet...

Страница 18: ...Numerical value of the switch on threshold Off threshold Numerical value of the switch off threshold Offset value Value that is added to each measured value Language German or English Menu language se...

Страница 19: ...ursor right SHORT To connect the Ud and Ud inputs short circuit of sensor signal ZERO To trigger an automatic zero adjustment Number Setting To set a numerical value and the date or time move the curs...

Страница 20: ...ation of the maximum minimum and mean value i e then re determined with the subsequent measured values By switching on the device By activating max min mean value mode By zero setting By starting perm...

Страница 21: ...ger than or equal to 32000 a new file is opened Therefore the number of lines can also be larger than 32000 in this mode In this mode at least one line i e one measured value is written per data set I...

Страница 22: ...s carefully DO NOT connect the amplifier to the PC until instructed to do so The BlueDAQ PC software is included on a USB Flash Drive with the amplifier or can be downloaded from www interfaceforce co...

Страница 23: ...nnect your 9330 to the PC via USB cable Once connected the driver installation window appears Select Install software from a list or specific source advanced users and Click Next FIGURE 1 FOUND NEW HA...

Страница 24: ...0 948 1924 www interfaceforce com Email contact interfaceforce com 800 947 5598 Document Number 15 216 Rev B Page 24 of 74 9 In the dialogue window Hardware installation click Continue installation FI...

Страница 25: ...e com Email contact interfaceforce com 800 947 5598 Document Number 15 216 Rev B Page 25 of 74 COM Ports Once windows is finished installing the device navigate to Device Manager and check for a new U...

Страница 26: ...click ADD CHANNEL FIGURE 6 ADD CHANNEL 1 In the Add Channel dialog box 1 1 Click Devicetype drop down and select BSC4 BSC8 BX8 or BSC2 9330 1 2 Click the Device dropdown box and select the device sel...

Страница 27: ...nels FIGURE 8 EXAMPLE BSC8 DEVICE 3 Each channel must now be scaled using the SCALING dialog box Each channel must be scaled independently If the BSC8 was purchased with Interface load cells and a Sys...

Страница 28: ...480 948 5555 Fax 480 948 1924 www interfaceforce com Email contact interfaceforce com 800 947 5598 Document Number 15 216 Rev B Page 28 of 74 5 Example scaling using Load Cell BSC8 Digital Bridge Ampl...

Страница 29: ...st Butherus Drive Scottsdale Arizona 85260 USA Phone 480 948 5555 Fax 480 948 1924 www interfaceforce com Email contact interfaceforce com 800 947 5598 Document Number 15 216 Rev B Page 29 of 74 FIGUR...

Страница 30: ...l using model WMC 100 load cell with 100 lbf capacity and 1 9587 mV V output After entering the values into the dialog box you must click Calculate and then OK Set FIGURE 12 EXAMPLE OF CALIBRATION FOR...

Страница 31: ...USA Phone 480 948 5555 Fax 480 948 1924 www interfaceforce com Email contact interfaceforce com 800 947 5598 Document Number 15 216 Rev B Page 31 of 74 Measurement and Recording 1 Click Set All Zero...

Страница 32: ...e Arizona 85260 USA Phone 480 948 5555 Fax 480 948 1924 www interfaceforce com Email contact interfaceforce com 800 947 5598 Document Number 15 216 Rev B Page 32 of 74 3 Click OK to Start Measuring FI...

Страница 33: ...USA Phone 480 948 5555 Fax 480 948 1924 www interfaceforce com Email contact interfaceforce com 800 947 5598 Document Number 15 216 Rev B Page 33 of 74 5 Recording Options are available FIGURE 17 MEA...

Страница 34: ...hone 480 948 5555 Fax 480 948 1924 www interfaceforce com Email contact interfaceforce com 800 947 5598 Document Number 15 216 Rev B Page 34 of 74 7 Value Display shows values in each Axis FIGURE 19 V...

Страница 35: ...55 Fax 480 948 1924 www interfaceforce com Email contact interfaceforce com 800 947 5598 Document Number 15 216 Rev B Page 35 of 74 1 Open Session allows you to open a previous session and start where...

Страница 36: ...ottsdale Arizona 85260 USA Phone 480 948 5555 Fax 480 948 1924 www interfaceforce com Email contact interfaceforce com 800 947 5598 Document Number 15 216 Rev B Page 36 of 74 3 Open File Monitor allow...

Страница 37: ...948 1924 www interfaceforce com Email contact interfaceforce com 800 947 5598 Document Number 15 216 Rev B Page 37 of 74 4 Configure Recording 4 1 Save Memory Data allows you to save data of the recor...

Страница 38: ...8 5555 Fax 480 948 1924 www interfaceforce com Email contact interfaceforce com 800 947 5598 Document Number 15 216 Rev B Page 38 of 74 4 2 Recording Options A Manually allows you to choose the run an...

Страница 39: ...e 480 948 5555 Fax 480 948 1924 www interfaceforce com Email contact interfaceforce com 800 947 5598 Document Number 15 216 Rev B Page 39 of 74 4 3 Advanced A Allows you to choose the timestamp record...

Страница 40: ...com Email contact interfaceforce com 800 947 5598 Document Number 15 216 Rev B Page 40 of 74 1 Configuration 1 1 1 Allows configurations of Axis to be viewed 2 Yt Recorder 2 1 Shows only the Yt Axis 3...

Страница 41: ...48 5555 Fax 480 948 1924 www interfaceforce com Email contact interfaceforce com 800 947 5598 Document Number 15 216 Rev B Page 41 of 74 5 Add Graph Window FIGURE 28 ADD GRAPH WINDOW 5 1 Add Plot A Al...

Страница 42: ...800 947 5598 Document Number 15 216 Rev B Page 42 of 74 Action FIGURE 30 ACTION 1 Start Measuring Yt Measures only the Yt axis 2 Start Measuring XY Measures only the XY Axis 3 Stop Measuring Stops me...

Страница 43: ...na 85260 USA Phone 480 948 5555 Fax 480 948 1924 www interfaceforce com Email contact interfaceforce com 800 947 5598 Document Number 15 216 Rev B Page 43 of 74 Device FIGURE 32 DEVICE 1 Load Settings...

Страница 44: ...Email contact interfaceforce com 800 947 5598 Document Number 15 216 Rev B Page 44 of 74 1 2 Load from File FIGURE 34 LOAD FROM FILE 2 Save Settings Save current settings 3 Frequency Frequency rate o...

Страница 45: ...rfaceforce com 800 947 5598 Document Number 15 216 Rev B Page 45 of 74 4 Advanced Settings 4 1 Filter FIGURE 36 FILTER 4 1 1 Input Channel Digital Filters are individually configurable for each of the...

Страница 46: ...IR is an Infinite Impulse Response digital filter with selectable type 4 1 3 Filter Type Can only set if Which filter is set to IIR FIGURE 40 FILTER TYPE A Low Pass frequencies above Cut off are dampe...

Страница 47: ...t off with lower order FIGURE 42 FILTER ORDER 4 1 6 Frequency response A Calculate filter and show results in frequency domain of sine waves at the input of different frequencies if successful B Espec...

Страница 48: ...ore all necessary information in the device if the calculation is successful The same settings will be stored for all 8 inputs if Apply to all input channels is checked FIGURE 45 STORE TO DEVICE 4 1 9...

Страница 49: ...ail contact interfaceforce com 800 947 5598 Document Number 15 216 Rev B Page 49 of 74 4 2 Digital I O FIGURE 47 DIGITAL I O 4 3 I O number 4 3 1 Devices can have up to 16 digital I O lines Enter numb...

Страница 50: ...l output becomes active if measuring value of corresponding channel is above ON threshold It becomes inactive if measuring value of corresponding channel is blow OFF threshold B Window comparator Digi...

Страница 51: ...85260 USA Phone 480 948 5555 Fax 480 948 1924 www interfaceforce com Email contact interfaceforce com 800 947 5598 Document Number 15 216 Rev B Page 51 of 74 4 4 Analog Out FIGURE 49 ANALOG OUT 4 4 1...

Страница 52: ...nalog out value will be half of the positive range B 2 5V at 0 5V or 5V FIGURE 51 USER OFFSET 4 4 3 User scaling factor Scaling factor to adapt analog input physical values to analog output A If using...

Страница 53: ...6 Rev B Page 53 of 74 4 5 Value Mode FIGURE 54 VALUE MODE 4 5 1 Acquire maximum and minimum Max Min value determination enabled This is a precondition for other max min settings also for some threshol...

Страница 54: ...etermined FIGURE 56 MAX VALUES ARE MAXIMUM OF ABSOLUTE VALUES 4 5 3 Value transmission Which values are in the value frame All channels are either actual values maximum values or minimum values FIGURE...

Страница 55: ...anently After power on the device transmits measuring values continuously B Values NOT transmitted permanently After power on the device transmits measuring values on request FIGURE 60 VALUE FRAME TRA...

Страница 56: ...will be set to 0 000000000 so that the noise around zero will be suppressed Set checkbox to enable this feature B Input Channel 0 Apply all channels Input channel to be used with Noise cut Set to 0 Us...

Страница 57: ...ADMINISTRATION 4 6 1 Write Protection A Inhibit parameter changing If the device is write protected the device parameters are secured from unintentional changing To disable write protection a device d...

Страница 58: ...nterfaceforce com 800 947 5598 Document Number 15 216 Rev B Page 58 of 74 record can be viewed and changed here Parameter record number 1 to 6 can be set by this to view and change its name A Displaye...

Страница 59: ...ocument Number 15 216 Rev B Page 59 of 74 4 7 3 Fault memory Some devices are capable of storing faults that are related to external connections E g broken sensor cable or value saturated FIGURE 68 FA...

Страница 60: ...rus Drive Scottsdale Arizona 85260 USA Phone 480 948 5555 Fax 480 948 1924 www interfaceforce com Email contact interfaceforce com 800 947 5598 Document Number 15 216 Rev B Page 60 of 74 1 Add new FIG...

Страница 61: ...contact interfaceforce com 800 947 5598 Document Number 15 216 Rev B Page 61 of 74 1 2 Communication Interface 1 2 1 Bits s Communication Bitrate If you aren t sure which Bitrate is appropriate to yo...

Страница 62: ...Drive Scottsdale Arizona 85260 USA Phone 480 948 5555 Fax 480 948 1924 www interfaceforce com Email contact interfaceforce com 800 947 5598 Document Number 15 216 Rev B Page 62 of 74 2 Channel Scaling...

Страница 63: ...60 USA Phone 480 948 5555 Fax 480 948 1924 www interfaceforce com Email contact interfaceforce com 800 947 5598 Document Number 15 216 Rev B Page 63 of 74 1 Multi axis Refer to step 5 2 Rosette Strain...

Страница 64: ...dy FIGURE 80 NUMBER OF ROSETTES 6 Actual Rosette If you have configured more than one rosette strain gauge here you can switch between the different rosette stain gauge settings FIGURE 81 ACTUAL ROSET...

Страница 65: ...lculation it should be entered as exact as possible Please multiply the values in lb in2 with 0 0068971125763 to get the modulus in N mm2 8 2 Poisson s ratio Enter the Poisson s ratio of the material...

Страница 66: ...value to the program Together with the gauge factor this value will be used to calculate the correct scaling factor automatically after the OK button is pressed NOTE The strain gauges must be wired in...

Страница 67: ...izona 85260 USA Phone 480 948 5555 Fax 480 948 1924 www interfaceforce com Email contact interfaceforce com 800 947 5598 Document Number 15 216 Rev B Page 67 of 74 9 TEDS Transducer Electronic Data Sh...

Страница 68: ...01 East Butherus Drive Scottsdale Arizona 85260 USA Phone 480 948 5555 Fax 480 948 1924 www interfaceforce com Email contact interfaceforce com 800 947 5598 Document Number 15 216 Rev B Page 68 of 74...

Страница 69: ...Scottsdale Arizona 85260 USA Phone 480 948 5555 Fax 480 948 1924 www interfaceforce com Email contact interfaceforce com 800 947 5598 Document Number 15 216 Rev B Page 69 of 74 2 Preferences FIGURE 8...

Страница 70: ...8 5555 Fax 480 948 1924 www interfaceforce com Email contact interfaceforce com 800 947 5598 Document Number 15 216 Rev B Page 70 of 74 Help FIGURE 91 HELP 1 Show Context Help FIGURE 92 SHOW CONTEXT H...

Страница 71: ...5260 USA Phone 480 948 5555 Fax 480 948 1924 www interfaceforce com Email contact interfaceforce com 800 947 5598 Document Number 15 216 Rev B Page 71 of 74 3 Create Settings Archive FIGURE 94 CREATE...

Страница 72: ...rejection DC 120 dB 100Hz 100 dB Analog Input 1 Input voltage range 0 10V Input resistance 56 kOhm Accuracy Linearity deviation 0 02 of unit Influence of temperature on the zero point per 10K Measure...

Страница 73: ...battery charging Supply voltage 10 27V Max 6 Hours Supply with USB standby operation Max 27 Hours Interface USB Version 2 0 Fullspeed Device classes Mass Storage Device Communication Device Class Mem...

Страница 74: ...tailed description of the problem Also please indicate if it is a warranty repair The sender is responsible for shipping charges freight insurance and proper packaging to prevent breakage in transit I...