ICHS-600KC-5
Tr
50
Tr
54
kW
58.5
kW
60.0
A
196.5
220V 3N 60Hz
R410A
6.2×6
m
3
m
3
/h
/h
31.0
30.0
MPa
1.0
80mm (Inside nominal diameter)
72 000
mm
2850
mm
2000
mm
mm
2110
kg
kg
1730
2000
L×W×H
Model
Cooling capacity
Heating capacity
Cooling consuming power
Cooling rated current
Power supply
Operation control
Safety device
Refrigerant
Type
Chargeing volume kg
Waterflow volume
Water pipe system
Air side heat exchanger
Outline dimension
N.W. of the unit
Operation Weight
Packing dimension
Type
L
W
H
Air flow volume
Inlet and outlet pipe dia.
Max. pressure
Water side heat
exchanger
Hydraulic resistance
lose kPa
Fin coil model
Shell & tube type heat exchanger
Control of wired controller, manual/auto startup, running state
display, failure alert etc.
High or low pressure switch, freeze-proof device, water flow volume
controller, Overcurrent device, power phase sequence device etc.
Table 9-1
9. APPLICABLE MODELS AND MAIN PARAMETERS
Heating consuming power
A
Heating rated current
189.0
2980×2135×2260
Notes: the above data is measured base on the following working condition.
Cooling mode under nominal working condition: water flow 0.172m
3
KN:RXWOHWZDWHUWHPSHUDWXUHRIFKLOOHG
water 7 , air inlet temperature of condenser 35 .
Heating mode under nominal working condition: water flow 0.172m
3
KN:RXWOHWZDWHUWHPSHUDWXUHRIKRWZDWHU
45 , air inlet temperature of condenser DB/WB 7/6 .