Owner’s & Installation manual 

Keep indoor unit, outdoor unit, power supply wiring and  
transmission wiring at least 1 meter away from televisions  
and radios. This is to prevent image interference and  
noise in those electrical appliances. (Noise may be  
generated depending on the conditions under which the  
electric wave is generated, even if 1 meter is kept.)  

There is enough room for installation and maintenance. 

The ceiling is horiztal, and its structure can endure the  
weight of the indoor unit. 

The outlet and the inlet are not impeded, and the influence  
of external air is the least. 

The air flow can reach throughout the room. 

The connecting water pipe and drainpipe could be  
extracted out easily. 

There is no direct radiation from heaters. 

5.    FAN COIL UNIT INSTALLATION

5.1   Installation place 

The indoor unit should be installed in a location that meets  
the following reauirements: 

5.2   Installation procedures for fresh air  
        intake duct connection 

Preparing the connection hole  
• 

Cut off the knockout hole on the side plate with a nipper. 

•     Cut the inner insulation of the hole portion with a cutter. 
      

 (refer to fig.5-4) 

Placing the insulation 
• 

Put the insulation tightly around the hole of the unit as   
shown. 
The ends of the side plate and the inner insulation must be  
completely adhered without leaving any clearance along the  
circumference of the hole. 
Make sure the inner surface of insulation tightly contacts the  
inner insulation edge and the side plate.  

(refer to fig.5-5) 

5.3   Install the main body 

The existing ceiling (to be horizontal) 

Cut a quadrangular hole of 880x880mm or 600x600mm in  
the ceiling according to the shape of the installation paper  
board.  

The center of the hole should be at the same position of  
that of the air conditioner body. 

Determine the lengths and outlets of the connecting pipe,  
drainpipe and cables. 

To balance the ceiling and to avoid vibration, please  
enforce the ceiling when necessary. 

Adjust the hexangular nuts on the four installation hooks  
evenly, to ensure the balance of the body. 

If the drainpipe is awry, leakage will be caused by the  
malfunction of the water-level switch. 

Adjust the position to ensure the gaps between the body  
and the four sides of ceiling are even. The body's lower  
part should sink into the ceiling for 10~12 mm.   

(refer to  

fig.5-6) 

In general, L is half of the screw length of the installation  
hook. 

(refer to fig.5-6) 

Locate the air conditioner firmly by wrenching the nuts  
after having adjusted the body's position well. 

(refer to  

fig.5-7) 

Select the position of installation hooks according to the  
hook holes on the installation board. 

Drill four holes of    12mm, 50~55mm deep at the selected   
positions on the ceiling. Then embed the expansible  
hooks (fittings). 

Face the concave side of the installation hooks toward the  
expansible hooks. Determine the length of the installation  
hooks from the height of ceiling, then cut off the 

 

unnecessary part. 

If the ceiling is extremely high, please determine the  
length of the installation hook according to facts. 

New built houses and ceilings 

In the case of new built house, the hook can be embedded  
in advance (refer to 2 mentioned above). But it should be  
strong enough to bear the indoor unit and will not become  
loose because of concrete shrinking. 

After installing the body, please fasten the installation paper  
board onto the air conditioner with bolts(M6X12) to 

 

determine in advance the sizes and positions of the hole  
opening on ceiling. 

(refer to fig.5-8) 

Refer to 3 above for  installation. 

Remove the installation paper board. 

Please first guarantee the flatness and horizontal of  
ceiling when installing it. 

Refer to 1 mentioned above for others. 

After installing the body, the four bolts(M6x12)must be  
fastened to the air conditioner onto ensure the body is  
grounded well. 

(refer to fig.5-1,fig.5-2,fig.5-3 and table 5-1 for specification.) 

CAUTION 

CAUTION 

5.4  OPERATION RANGE

Use the system in the following temperature for safe and
effective operation.

Cooling operation 

Heating operating

(cooling only
type without)

Mode 

Temperature 

Outdoor 

temperature 

Room 

temperature 

water inlet 

temperature

0°C

30°C

17°C

32°C

30°C

75°C

3°C

20°C

-15°C

24°C

0°C

43°C

Table 5-1 

NOTE 

If air conditioner is used outside the above conditions, it 
may cause the unit to function abnormally. 
 
The phenomenon is normal that the surface of air 
conditioning may condense water when the relative larger 
humidity in room, please close the door and window. 
 
Optimum performance will be achieved within these 
operating temperature range. 
 
Water system operating pressuer: Max: 1.6MPa, Min: 
0.15MPa.  

Содержание IC4H-04KF-3

Страница 1: ...MAN ICC4H 1112 Compact Four Way Cassette Chilled Water INSTALLATION OWNER S MANUAL www intensity com mx IC4H 04KF 3...

Страница 2: ...ries parts and specified parts for installation otherwise it will cause the set to fall water leakage electrical shock and fire The appliance must be installed 2 3m above floor The appliance shall not...

Страница 3: ...all the indoor and outdoor units power supply wiring and connecting wires at least 1 meter away from televisions or radios in order to prevent image interference or noise Depending on the radio waves...

Страница 4: ...n sheath 8 Out let pipe clasp 7 Out let pipe sheath 6 Out let pipe pipe 9 Tightening band 14 Installation owner s manual 15 Remote controller manual 10 Remote controller 11 Frame 12 Mounting screw ST2...

Страница 5: ...ceiling are even The body s lower part should sink into the ceiling for 10 12 mm refer to fig 5 6 In general L is half of the screw length of the installation hook refer to fig 5 6 Locate the air cond...

Страница 6: ...g point of drain pipe 840 Body 950 Panel 330 Drain side Drain side Drain side Tubing side Unit mm Unit mm Unit mm 780 Hook location 780 Hook location 780 Hook location 840 Body 840 Body 840 Body 950 P...

Страница 7: ...ers to choose Type H mm Four way cassette Four way cassette compact 45 50 Height of the front panel Ceiling 600mm ceiling hole Ground 261 213 Panel Inlet Outlet Outlet Water pipe joint Connecting poin...

Страница 8: ...THE DRAIN PIPE 7 6 1 Install the drain pipe of indoor unit 1 The drainpipe can use PVC pipe external diameter about 37 39mm inner diameter is 32mm 2 Joint drainpipe connector to the end side of water...

Страница 9: ...her equipment has to be connected with this power line For detailed installation acceptance please refer to your power supplier if restrictions do apply for products like washing machines air conditio...

Страница 10: ...The ground wiring is connected correctly The length of the tubing has been recorded The power voltage fits the rated voltage of the air conditioner There is no obstacle at the outlet and inlet of the...

Страница 11: ...ds the middle simultaneously as indicated in fig 9 1 Then pull down the air in grill The control box cables which are originally connected with the main body electrical terminators must be pulled off...

Страница 12: ...s in order to shelter from sunshine Reduce heat source AC cooling capacity reduces normal Check leakage Symptoms Causes Unit does not start Air flowing normally but completely can t cooling Units star...

Страница 13: ...f the remote controller to the infrared signal receiver of the indoor unit and then repeatly push the ON OFF button twice The indication on the display disappears after a lapse of time Check whether t...

Страница 14: ...O Malfunction running lamp timer lamp defrosting lamp alarm lamp 1 2 3 4 5 Room temperature sensor checking channel is abnormal Evaporator sensor checking channel is abnormal EEPROM malfunction Water...

Страница 15: ......

Отзывы: