intensity IC4H-04KF-3 Скачать руководство пользователя страница 3

2

Owner’s & Installation manual 

3.    PARTS NAMES

lug 

drain orifice 

Main body 

Panel 

Influent value of cooling  
water collector 

Effluent value of cooling  
water collector 

Water return orifice for  
plastic water tray 

Effluent value of heating water collector 

Iffluent value of heating  
water collector 

Four-way Cassette 
       (compact) 

lug 

drain orifice 

Main body 

Panel 

water heighgage 

Influent value of cooling  
water collector 

Effluent value of cooling  
water collector 

Water return orifice for plastic water tray 

Effluent value of heating water collector 

Iffluent value of heating  
water collector 

 

Four-way Cassette 

DISPOSAL

Do not dispose this product as unsor- 

ted municipal waste. Collection of such waste sepa- 
rately for

 

special treatment is necessary. 

Ground the air conditioner.

 

Do not connect the ground wire to gas or water pipes, 
lightning rod or a telephone ground wire.Incomplete 
grounding may result in electric shocks. 
 

Be sure to install an earth leakage breaker.

 

Failure to install an earth leakage breaker may result in 
electric shocks.

 

 

Connect the outdoor unit wires , then connect the indoor 
unit wires.

  

You are not allow to connect the air conditioner with the 
power source until wiring and piping the air conditioner is 
done. 

 
While following the instructions in this installation 
manual, install drain piping in order to ensure proper 
drainage and insulate piping in order to prevent 
condensation.

 

Improper drain piping may result in water leakage and 
property damage. 
 

Install the indoor and outdoor units, power supply wiring 
and connecting wires at least 1 meter away from 
televisions or radios in order to prevent image 
interference or noise. 

Depending on the radio waves, a distance of 1 meter may not 
be sufficient enough to eliminate the noise. 

 
This appliance is not intended for use by persons 
(including children) with reduced physical,sensory or 
mental capabilities, or lack of experience and knowledge, 
unless they have been given supervision or instruction 
concerning use of the appliance by a person responsible 
for their safety. 

 

 
 
 
 
 
 
Don't install the air conditioner in the following locations: 

There is petrolatum existing. 
 
There is salty air surrounding (near the coast). 
 
There is caustic gas (the sulfide, for example) existing  
in the air (near a hot spring). 
 
The Volt vibrates violently (in the factories). 
 
In buses or cabinets. 
 
In kitchen where it is full of oil gas. 
 
There is strong electromagnetic wave existing. 
 
There are inflammable materials or gas. 
 
There is acid or alkaline liquid evaporating. 
 
Other special conditions. 

CAUTION 

To install properly, please read this "installation manual" at 
first. 
 
The air conditioner must be installed by qualified persons. 
 
When installing the indoor unit or its tubing, please follow 
this manual as strictly as possible. 
 
If the air conditioner is installed on a metal part of the 
building, it must be electrically insulated according to the 
relevant standards to electrical appliances.

 

 
When all the installation work is finished, please turn on 
the power only after a thorough check. 
 
Regret for no further announcement if there is any change 
of this manual caused by product improvement. 

2.    INSTALLATION INFORMATION

Содержание IC4H-04KF-3

Страница 1: ...MAN ICC4H 1112 Compact Four Way Cassette Chilled Water INSTALLATION OWNER S MANUAL www intensity com mx IC4H 04KF 3...

Страница 2: ...ries parts and specified parts for installation otherwise it will cause the set to fall water leakage electrical shock and fire The appliance must be installed 2 3m above floor The appliance shall not...

Страница 3: ...all the indoor and outdoor units power supply wiring and connecting wires at least 1 meter away from televisions or radios in order to prevent image interference or noise Depending on the radio waves...

Страница 4: ...n sheath 8 Out let pipe clasp 7 Out let pipe sheath 6 Out let pipe pipe 9 Tightening band 14 Installation owner s manual 15 Remote controller manual 10 Remote controller 11 Frame 12 Mounting screw ST2...

Страница 5: ...ceiling are even The body s lower part should sink into the ceiling for 10 12 mm refer to fig 5 6 In general L is half of the screw length of the installation hook refer to fig 5 6 Locate the air cond...

Страница 6: ...g point of drain pipe 840 Body 950 Panel 330 Drain side Drain side Drain side Tubing side Unit mm Unit mm Unit mm 780 Hook location 780 Hook location 780 Hook location 840 Body 840 Body 840 Body 950 P...

Страница 7: ...ers to choose Type H mm Four way cassette Four way cassette compact 45 50 Height of the front panel Ceiling 600mm ceiling hole Ground 261 213 Panel Inlet Outlet Outlet Water pipe joint Connecting poin...

Страница 8: ...THE DRAIN PIPE 7 6 1 Install the drain pipe of indoor unit 1 The drainpipe can use PVC pipe external diameter about 37 39mm inner diameter is 32mm 2 Joint drainpipe connector to the end side of water...

Страница 9: ...her equipment has to be connected with this power line For detailed installation acceptance please refer to your power supplier if restrictions do apply for products like washing machines air conditio...

Страница 10: ...The ground wiring is connected correctly The length of the tubing has been recorded The power voltage fits the rated voltage of the air conditioner There is no obstacle at the outlet and inlet of the...

Страница 11: ...ds the middle simultaneously as indicated in fig 9 1 Then pull down the air in grill The control box cables which are originally connected with the main body electrical terminators must be pulled off...

Страница 12: ...s in order to shelter from sunshine Reduce heat source AC cooling capacity reduces normal Check leakage Symptoms Causes Unit does not start Air flowing normally but completely can t cooling Units star...

Страница 13: ...f the remote controller to the infrared signal receiver of the indoor unit and then repeatly push the ON OFF button twice The indication on the display disappears after a lapse of time Check whether t...

Страница 14: ...O Malfunction running lamp timer lamp defrosting lamp alarm lamp 1 2 3 4 5 Room temperature sensor checking channel is abnormal Evaporator sensor checking channel is abnormal EEPROM malfunction Water...

Страница 15: ......

Отзывы: