Owner’s & Installation manual 

CONTENTS

PAGE 

PRECAUTIONS........................................................................................1

INSTALLATION INFORMATION................................................................2

ATTACHED FITTINGS..............................................................................3

FAN COIL UNIT INSTALLATION...............................................................4

CONNECT THE DRAIN PIPE.....................................................................7

WIRING...................................................................................................8

TEST OPERATION....................................................................................9

MAINTENANCE......................................................................................10

TROUBLESHOOTING.............................................................................11

PARTS NAMES........................................................................................2

  

Be sure to be in conformity with the local, national and 
international laws and regulations.

Read "PRECAUTIONS" carefully before installation.

The following precautions include important safty items. 
Observe them and never forget.

Keep this manual  in a handy place for future reference.

Before out from factory, FAN COIL UNIT (AIR UNITS) has 
passed Fan Coil Overpressure Resistant Test, Statically 
and Dynamically Balanced Adjustment, Noise Test, Air 
(cool) Volume Test, Electric Property Test, Outline Quality 
Detection. 

1.    PRECAUTIONS

The safety precautions listed here are divided into two categories. In 
either case, important safety information is listed which must be read 
carefully. 

WARNING 

After completing the installation, make sure that the unit operates 
properly during the start-up operation. Please instruct the customer 
on how to operate the unit and keep it maintained.

Be sure only trained and qualified service personnel to 
install, repair or service the equipment. 

Improper installation, repair, and maintenance may result in 
electric shocks, short-circuit, leaks, fire or other damage to 
the equipment. 

Failure to observe a warning may result in death.

Failure to observe a caution may result in injury or 
damage to the equipment.

CAUTION 

WARNING 

Install according to this installation instructions strictly. 

 

If installation is defective, it will cause water leakage, 
electrical shock and fire. 
 

When installing the unit in a small room, take measures 
against to keep refrigerant concentration from exceeding 
allowable safety limits in the event of refrigerant leakage.

 

Contact the place of purchase for more information. 
Excessive refrigerant in a closed ambient can lead to oxygen 
deficiency.

 

 

Use the attached accessories parts and specified parts 
for installation. 

 

otherwise, it will cause the set to fall, water  leakage, 
electrical shock and fire. 
 

The appliance must be installed 2.3m above floor. 
 
The appliance shall not be installed in the laundry. 
 
Before obtaining access to terminals, all supply circuits 
must be disconnected. 
 
The appliance must be positioned so that the plug is 
accessible. 
 
The enclosure of the appliance shall be marked by word, 
or by symbols, with the direction of the fluid flow. 

 

For electrical work, follow the local national wiring 
standard, regulation and this installation instructions. An 
independent circuit and single outlet must be used. 

 

If electrical circuit capacity is not enough or defect in 
electrical work, it will cause electrical shock fire. 
 

Use the specified cable and connect tightly and clamp 
the cable so that no external force will be acted on the 
terminal.

  

If connection or fixing is not perfect, it will cause heat-up or 
fire at the connection. 

 
Wiring routing must be properly arranged so that control 
board cover is fixed properly. 

 

If control board cover is not fixed perfectly, it will cause 
heat-up at connection point of terminal, fire or electrical 
shock. 
 

If the supply cord is damaged, it must be replaced by the 
manufacture or its service agent or a similarly qualified 
person in order to avoid a hazard. 
 
An all-pole disconnection switch having a contact 
separation of at least 3mm in all poles should be 
connected in fixed wiring. 
 
When carrying out piping connection, take care not to let 
air substances go into refrigeration cycle. 

 

Otherwise, it will cause lower capacity, abnormal high 
pressure in the refrigeration cycle. 
 

Do not modify the length of the power supply cord or use 
of extension cord, and do not share the single outlet with 
other electrical appliances. 

 

Otherwise, it will cause fire or electrical shock. 
 

If the water leaks during installation, ventilate the area 
immediately. 
 
After completing the installation work, check that the 
water does not leak. 
 

The cool water in the unit is not lower than 3

, hot water is 

not higher than 75

. Water in the unit must clean, air quality 

must meet to the standard of PH=6.5~7.5.

   

Содержание IC4H-04KF-3

Страница 1: ...MAN ICC4H 1112 Compact Four Way Cassette Chilled Water INSTALLATION OWNER S MANUAL www intensity com mx IC4H 04KF 3...

Страница 2: ...ries parts and specified parts for installation otherwise it will cause the set to fall water leakage electrical shock and fire The appliance must be installed 2 3m above floor The appliance shall not...

Страница 3: ...all the indoor and outdoor units power supply wiring and connecting wires at least 1 meter away from televisions or radios in order to prevent image interference or noise Depending on the radio waves...

Страница 4: ...n sheath 8 Out let pipe clasp 7 Out let pipe sheath 6 Out let pipe pipe 9 Tightening band 14 Installation owner s manual 15 Remote controller manual 10 Remote controller 11 Frame 12 Mounting screw ST2...

Страница 5: ...ceiling are even The body s lower part should sink into the ceiling for 10 12 mm refer to fig 5 6 In general L is half of the screw length of the installation hook refer to fig 5 6 Locate the air cond...

Страница 6: ...g point of drain pipe 840 Body 950 Panel 330 Drain side Drain side Drain side Tubing side Unit mm Unit mm Unit mm 780 Hook location 780 Hook location 780 Hook location 840 Body 840 Body 840 Body 950 P...

Страница 7: ...ers to choose Type H mm Four way cassette Four way cassette compact 45 50 Height of the front panel Ceiling 600mm ceiling hole Ground 261 213 Panel Inlet Outlet Outlet Water pipe joint Connecting poin...

Страница 8: ...THE DRAIN PIPE 7 6 1 Install the drain pipe of indoor unit 1 The drainpipe can use PVC pipe external diameter about 37 39mm inner diameter is 32mm 2 Joint drainpipe connector to the end side of water...

Страница 9: ...her equipment has to be connected with this power line For detailed installation acceptance please refer to your power supplier if restrictions do apply for products like washing machines air conditio...

Страница 10: ...The ground wiring is connected correctly The length of the tubing has been recorded The power voltage fits the rated voltage of the air conditioner There is no obstacle at the outlet and inlet of the...

Страница 11: ...ds the middle simultaneously as indicated in fig 9 1 Then pull down the air in grill The control box cables which are originally connected with the main body electrical terminators must be pulled off...

Страница 12: ...s in order to shelter from sunshine Reduce heat source AC cooling capacity reduces normal Check leakage Symptoms Causes Unit does not start Air flowing normally but completely can t cooling Units star...

Страница 13: ...f the remote controller to the infrared signal receiver of the indoor unit and then repeatly push the ON OFF button twice The indication on the display disappears after a lapse of time Check whether t...

Страница 14: ...O Malfunction running lamp timer lamp defrosting lamp alarm lamp 1 2 3 4 5 Room temperature sensor checking channel is abnormal Evaporator sensor checking channel is abnormal EEPROM malfunction Water...

Страница 15: ......

Отзывы: