INTELLITEC
PDX RV LLC
BATTERY DISCOECT
Check battery voltage, the voltage must be greater
than 10.5 Volts DC for the latching relay to close or
open. If batteries are below 10.5 Volts DC, charge
batteries and retest. If the batteries are charged and
are above 10.5 Volts DC go to step 48.
Possible
Cause / Solution
Trouble Shooting
Problem
Chassis Relay won't
engage (latch),
BD2
& BD3 MODELS
ONLY
STEP 47
With an assistant, press and hold momentary
switch, at the same time check for voltage across
the coil terminals of the chassis battery relay(+ on
the "I" terminal and ground on the "S" terminal),
If
0 volts go to step 49. If voltage is 10.5 VDC or
larger between the “I” & “S” terminals, replace
chassis relay.
Remove battery disconnect panel from cabinet /
console and with a multi-meter set on DC voltage,
measure between the orange wire at pin # 7 and the
black wire on pin # 12
.
The voltage should read
the same approximate value as the
batteries. If not
replace harness, refer to PARTS LINK#1 (page 7).
If the voltage reading is the same go to step 50.
STEP 48
STEP 49
STEP 50
With a multi-meter set on DC voltage, measure
between the orange wire at pin # 7 and the gray
wire on pin # 8 while the switch is depressed
.
The
voltage should read the same approximate value as
the
batteries. If not replace disconnect panel, refer
to PARTS LINK # 2 (page8). If the reading is the
same go to step 51.
With a multi-meter set on DC voltage, measure
between the black wire at pin # 12 and the violet
wire on pin # 6 while the switch is pressed
.
The
voltage should read the same approximate value as
the
batteries. If not replace disconnect panel, refer
to PARTS LINK # 2 (page 8).
STEP 51
16
Содержание Battery Disconnect BD0
Страница 22: ...PAGE 22...
Страница 23: ...PAGE 23...