BATTERY DISCOECT
Trouble Shooting
Possible
Problem
Cause/Solution
House Relay won't
engage,
BD0 & BD1
MODELS ONLY
Check fuses on relay. If not blown go to step 3, if
blown replace with same size fuse and retest. If fuse /
fuses re-blow go to step 2.
Check battery voltage, the voltage must be greater
than 10.5 Volts DC for the latching relay to close or
open. If batteries are below 10.5 Volts DC, charge
batteries and retest. If the batteries are charged and
are above 10.5 Volts DC go to step 4.
With an assistant, press and hold momentary
switch, at the same time check for voltage across
the coil terminals (+ on the "I" terminal and
ground on the "S" terminal),
If 0 volts go to step
5. If voltage is 10.5 VDC or larger between the
“I” & “S” terminals, replace relay.
INTELLITEC
7
PDX RV LLC
Disconnect harness from battery disconnect
panel inside of RV, replace fuse, if fuse re-blows
either attempt to find damage in the harness
and repair or replace harness, (see PARTS
LINK# 1 below). If fuse doesn’t blow then go to
step 3
BDO / BD1 HARNESS, 11-00063-000
Parts link:
http://www.pdxrv.com/catalog/i2756.html
BD2 / BD2 HARNESS, 11-00139-000
Parts link:
http://www.pdxrv.com/catalog/i2761.html
STEP 1
STEP 2
STEP 3
STEP 4
Remove battery disconnect panel from cabinet /
console and with a multi-meter set on DC voltage,
measure between the red wire at pin # 3 and the
black wire on pin # 6
.
The voltage should read the
same approximate value as the
batteries. If not
replace harness, refer to PARTS LINK#1. If the
voltage reading is the same go to step 6.
STEP 5
With a multi-meter set on DC voltage, measure
between the red wire at pin # 3 and the brown wire
on pin # 1 while the switch is depressed
.
The
voltage should read the same approximate value as
the
batteries. If not replace disconnect panel, refer
to PARTS LINK # 2 (page 8). If the reading is the
same go to step 7.
STEP 6
PARTS LINK #1