Once connected, the cabling between the module and power supply should resemble the picture
below:
Before reconnecting power and
turning on your modular system,
double check that the ribbon cable is
fully seated on both ends and that all
the pins are correctly aligned. If the
pins are misaligned in any direction or
the ribbon is backwards you can
cause damage to your module, power
supply, or other modules.
After you have confirmed all the
connections, you can reconnect the
power cable and turn on your modular
system. You should immediately
check that all your modules have powered on and are functioning correctly. If you notice any
anomalies, turn your system off right away and check your cabling again for mistakes.
Connecting an Optional Expander Module
You can connect an
Intellijel Gx
(or
Qx
) gate expander module to Metropolix to provide eight
additional gate and trigger outputs, which you configure via the
1.
Turn off power to your eurorack system.
2.
Using the power power cable included with your expander module (Gx or Qx), connect one end
to the module’s 10-pin power connector and the other to the 16-pin power socket on your
eurorack system’s powered bus board — paying attention to polarity (aligning the red stripe as
described previously).
3.
Using the I2C cable included with your expander module, connect one end to the module’s 6-pin
I2C connector and the other end to the I2C port on your Metropolix module. Both ports are
shrouded to ensure they can be connected in only one direction.
4.
Power up your eurorack system.
IMPORTANT !!! : Always power down the modules before connecting or disconnecting an
I2C cable.
Metropolix Manual