- 19 -
The scale can be controlled with following commands.
Basic Commands:
PLUxx
Select PLU from scale memory
T
Tare current weight value
T123.456
Numeric tare value
Z
Zero
P
M+
Store and print current results
MR
Recall memory values to scale display
MC
Clear memory
U123.456
Store unit weight of 123.456 kg / lb
S123
Enter sample size of parts 123 . Same as pressing
SL
Select local scale to be used
SR
Select remote scale to be used
Printing Commands:
\L
Scale: Local or Remote
\I
User ID number
\S
Scale ID number
\N
Net weight
\G
Gross Weight
\T
Tare weight
\U
Unit weight
\P
Count
\C
Total Count
\W
Total Weight
\M
Number of items stored in memory
\B
A blank / space line
PLU entry using RS 232 interface
This will allow the scale data to be sent from a PC program as well as from the keypad.
The most common PLUs can be stored and recalled from the scale memory. Other PLU
data can be stored on a PC, then the text data, unit weight and tare data can be sent
from the PC to PLU00. This can then be used and over written each operation.
OPERATION:
Send tare data to set any tare value to be stored with PLU. i.e. “T0.150” <CR>. If
no tare is needed then you may send T0 to delete any present tare data.
Send the unit weight to be stored with PLU. ie. “U12.3456” <CR>
Содержание QHD+15
Страница 20: ... 20 Send PLU text data to be stored with current TARE and U W values ie SPLU01 Parts CR ...
Страница 31: ... 31 12 CIRCUIT DIAGRAM ...
Страница 32: ... 32 ...
Страница 33: ... 33 13 DRAWING ...