IA-2660-Ui
33
www.intelligent-appliance.com
Specifications are subject to change without notice
Isolated TCP/IP
96 Digital TTL/LVTTL
Pluggable Terminal Blocks
!aa6dd
–
Set baud rate
Description
This command defines the devices
baud rates.
Mode register #51
must be set to “82” first. (
!00582
)
Syntax
!aa6dd <CR>
!
Delimiter character
aa
Hexadecimal address of the device
6
Change device baud rate command
dd
Two characters representing the desired baud rate:
12
1200
24
2400
48
4800
96
9600
19
19200 (default)
38
38400
57
57600
11
115200
<CR> Carriage Return - End of command
Response
|dd<CR> if the command was valid
|
Response delimiter
dd
New baud rate
<CR> Carriage Return - End of response
Example
Command: !01696<CR>
Response: |96<CR>
Change the baud rate of the device at address 01Hex to 9600
1.
Mode must be set to “8
2
” first
. (
!00582
)
2.
Changes will take effect after the next power up. (Power off)
3.
Make sure setting the mode back to normal right after changing
the BR.
Note
!