IA-2660-Ui
25
www.intelligent-appliance.com
Specifications are subject to change without notice
Isolated TCP/IP
96 Digital TTL/LVTTL
Pluggable Terminal Blocks
?aaPD
–
Get Device I/O Structure settings
Description
This command reads the module
’s
I/O Structure settings
Syntax
?aaPD<CR>
?
Delimiter character
aa
Hexadecimal address of the device
PD
Get Device I/O Structure settings
<CR>
Carriage Return - End of command
Response
_0ddd<CR> if the command was valid
_0ddd I/O Structure (0000-0FFF)
<CR>
Carriage Return - End of response
Example
Command: ?00PD<CR>
Response: _0001<CR>
In this example the entire module is set to INPUT except the lowest
Byte.
_0000 All Device Bytes are set to INPUT
_0FFF All Device Bytes are set to OUTPUT
_0800 All Bytes are set to INPUT except the highest one, that is set to
output (Pin 89-96)