background image

IA-2660-Ui

 

www.intelligent-appliance.com

 

 

Specifications are subject to change without notice 

Isolated TCP/IP 
96 Digital TTL/LVTTL 
Pluggable Terminal Blocks 

Digital Input / Output Terminal Block 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

2

 

3

 

4

 

5

 

6

 

7

 

8

 

Ei1

 

GND

 

Digital Input

 

TB1-Upper

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9

 

10

 

11

 

12

 

13

 

14

 

15

 

16

 

Ei1

 

GND

 

Digital Input

 

TB1-Lower

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

17

 

18

 

19

 

20

 

21

 

22

 

23

 

24

 

Ei2

 

GND

 

Digital Input

 

TB2-Upper

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

25

 

26

 

27

 

28

 

29

 

30

 

31

 

32

 

Ei2

 

GND

 

Digital Input

 

TB2-Lower

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

33

 

34

 

35

 

36

 

37

 

38

 

39

 

40

 

Ei3

 

GND

 

Digital Input

 

TB3-Upper

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

41

 

42

 

43

 

44

 

45

 

46

 

47

 

48

 

Ei3

 

GND

 

Digital Input

 

TB3-Lower

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GND

 

Eo3

 

48

 

47

 

46

 

45

 

44

 

43

 

42

 

41

 

Digital Output

 

TB6-Lower

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GND

 

Eo3

 

40

 

39

 

38

 

37

 

36

 

35

 

34

 

33

 

Digital Output

 

TB6-Upper

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GND

 

Eo2

 

32

 

31

 

30

 

29

 

28

 

27

 

26

 

25

 

Digital Output

 

TB5-Lower

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GND

 

Eo2

 

24

 

23

 

22

 

21

 

20

 

19

 

18

 

17

 

Digital Output

 

TB5-Upper

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GND

 

Eo1

 

16

 

15

 

14

 

13

 

12

 

11

 

10

 

9

 

Digital Output

 

TB4-Lower

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GND

 

Eo1

 

8

 

7

 

6

 

5

 

4

 

3

 

2

 

1

 

Digital Output

 

TB4-Upper

 

 

I/O 

I/O 

I/O 

I/O 

I/O 

I/O 

I/O 

I/O 

I/O 

I/O 

I/O 

I/O 

E1 
GND 

E5 
GND 

E6 
GND 

E4 
GND 

E3 
GND 

E2 
GND 

 

GND 
E7 
56 
55 
54 
53 
52 
51 
50 
49 

GND 
E8 
64 
63 
62 
61 
60 
59 
58 
57 

GND 
E9 
72 
71 
70 
69 
68 
67 
66 
65 
 

GND 
E10 
80 
79 
78 
77 
76 
75 
74 
73 

GND 
E11 
88 
87 
86 
85 
84 
83 
82 
81 

GND 
E12 
96 
95 
94 
93 
92 
91 
90 
89 

Содержание IA-2660-Ui

Страница 1: ...User Manual Version 0418 www intelligent appliance com IA 2660 Ui Isolated USB port 96 Digital I O 3 3V 5V Pluggable Terminal Blocks...

Страница 2: ...nd 24 7 technical support Intelligent Appliance delivers services via the internet The dedicated website offers large knowledgebase database that include full information for Development Engineers Ins...

Страница 3: ...ERSION 16 AA2 GET DIGITAL OUTPUT STATUS 17 AA3NN GET BIT STATE 19 AA5 GET DEVICE MODE REGISTER 50 20 AA51 GET DEVICE MODE REGISTER 51 21 AAI GET DIGITAL INPUTS STATUS 22 AAID GET MODULE S ID NUMBER 24...

Страница 4: ...yte or an Output Byte The IA 2660 Ui internal circuits are set to operate by 5V supply voltage or by 3 3V software selected in order to best fit customer s needs The on board Pluggable Screw Terminal...

Страница 5: ...ucture Tri State Buffered Outputs Rated Current 24 mA Rated Voltage 3 3V 5V software controlled Digital Inputs Channels 96 Input Voltage Range 3 3V 5V software controlled Pull up Resistor 22K OHM Pull...

Страница 6: ...T authorized for use as components in life support devices or systems Do not operate the device in a manner not specified in the documentation Misuse of the device may result in injury and or damage e...

Страница 7: ...IA 2660 Ui 7 www intelligent appliance com Specifications are subject to change without notice Isolated TCP IP 96 Digital TTL LVTTL Pluggable Terminal Blocks Installation System Wiring USB Host PC USB...

Страница 8: ...e Isolated TCP IP 96 Digital TTL LVTTL Pluggable Terminal Blocks Pin Assignment J1 Main Port USB TB1 TB2 TB3 TB4 TB5 TB6 Digital Input Output signals TB7 Power Supply and Relay Auxiliary Relay Contact...

Страница 9: ...1 42 43 44 45 46 47 48 Ei3 GND Digital Input TB3 Lower GND Eo3 48 47 46 45 44 43 42 41 Digital Output TB6 Lower GND Eo3 40 39 38 37 36 35 34 33 Digital Output TB6 Upper GND Eo2 32 31 30 29 28 27 26 25...

Страница 10: ...IA 2660 Ui 10 www intelligent appliance com Specifications are subject to change without notice Isolated TCP IP 96 Digital TTL LVTTL Pluggable Terminal Blocks Internal Circuits...

Страница 11: ...unit and by a creation of new Serial COM that can be easily found on the Device Manager screen At this stage you can easily control the device I O s by either any serial control software or by the IA3...

Страница 12: ...ine Knowledge Base www intelligent appliance com Handling IA 3000 Utility 1 Start the IA3000Util Utility by pressing Start Manu on the computer s main screen select All Programs and finally IA3000Util...

Страница 13: ...subject to change without notice Isolated TCP IP 96 Digital TTL LVTTL Pluggable Terminal Blocks 6 Once the device is selected its form will be shown on the control panel label 7 Left clicking the but...

Страница 14: ...15 AA1 GET DEVICE FIRMWARE VERSION 16 AA2 GET DIGITAL OUTPUT STATUS 17 AA3NN GET BIT STATE 19 AA5 GET DEVICE MODE REGISTER 50 20 AA51 GET DEVICE MODE REGISTER 51 21 AAI GET DIGITAL INPUTS STATUS 22 A...

Страница 15: ...d address Syntax aa0 CR Delimiter character aa Hexadecimal address of the device 0 Get device Model command CR Carriage Return End of command Response _nnnn CR if the command was valid _ Response deli...

Страница 16: ...aracter aa Hexadecimal address of the device 1 Get device Version command CR Carriage Return End of command Response _nnnn CR if the command was valid _ Response delimiter nnnn A string containing the...

Страница 17: ...e _ABCDEFGHIJKLMNOPQRSTUVWX CR if the command was valid _ Delimiter character A 1st output nibble B 2nd output nibble C 3rd output nibble D 4th output nibble E 5th output nibble F 6th output nibble G...

Страница 18: ...gital TTL LVTTL Pluggable Terminal Blocks Output Bit Table Value 8 4 2 1 8 4 2 1 8 4 2 1 Bit 3 2 1 0 3 2 1 0 3 2 1 0 I O 95 94 93 92 91 90 89 88 3 2 1 0 Nibble A B X Bit 0 refers to input Pin 1 Bit 95...

Страница 19: ...aracter aa Hexadecimal address of the device 3 Acquiring defined Bit DATA command nn Bit location 00 for Pin 1 01 for Pin 2 and 5F for Pin 96 CR Carriage Return End of command Response _nn b CR if the...

Страница 20: ...CR Carriage Return End of command Response _dd CR if the command was valid dd Mode 00 FF 82 Enable BR change 02 Report on command errors 00 Normal CR Carriage Return End of command Example Command 00...

Страница 21: ...mode register 51 data Syntax aa51 CR Delimiter character aa Hexadecimal address of the device 51 Mode register 51 command CR Carriage Return End of command bit Value dd Function Internal Voltage 4 1...

Страница 22: ..._ABCDEFGHIJKLMNOPQRSTUVWX CR if the command was valid _ Delimiter character A 1st inputs nibble B 2nd inputs nibble C 3rd inputs nibble D 4th inputs nibble E 5th inputs nibble F 6th inputs nibble G 7t...

Страница 23: ...gital TTL LVTTL Pluggable Terminal Blocks Output Bit Table Value 8 4 2 1 8 4 2 1 8 4 2 1 Bit 3 2 1 0 3 2 1 0 3 2 1 0 I O 95 94 93 92 91 90 89 88 3 2 1 0 Nibble A B X Bit 0 refers to input Pin 1 Bit 95...

Страница 24: ...ggable Terminal Blocks aaID Get module s ID number Description This command reads the Device ID Syntax aaID CR Delimiter character aa Hexadecimal address of the device ID Command for read ID CR Carria...

Страница 25: ...aa Hexadecimal address of the device PD Get Device I O Structure settings CR Carriage Return End of command Response _0ddd CR if the command was valid _0ddd I O Structure 0000 0FFF CR Carriage Return...

Страница 26: ...imal address of the device PU Get Pull ups settings CR Carriage Return End of command Response _dd CR if the command was valid _dd I O Structure 00 3F CR Carriage Return End of response Example Comman...

Страница 27: ...state Description This command reads the status of the relay Syntax aaS CR Delimiter character aa Hexadecimal address of the device S Read relay status CR Carriage Return End of command Response _dd C...

Страница 28: ...r aa Hexadecimal address of the device 2 System control command d Digital output activation command data for each nibble in hex format CR Carriage Return End of command Response dddddddddddddddddddddd...

Страница 29: ...0 5F Description This command activates a single output Syntax aa3dd CR Delimiter character aa Hexadecimal address of the device 3 Single output activation command dd N Output ID in hex format CR Carr...

Страница 30: ...escription This command De activates a single output Syntax aa4dd CR Delimiter character aa Hexadecimal address of the device 4 De activate output N command dd N Output ID in hex format CR Carriage Re...

Страница 31: ...mode command dd Mode 00 FF 82 Enables BR and Address changes 02 Report on command errors 00 Normal Factory default CR Carriage Return End of command Response dd EE OK if the command was valid Example...

Страница 32: ...Internal Voltage 3V 5V Syntax aa51dd CR Delimiter character aa Hexadecimal address of the device 51 System mode command dd Mode register 51 CR Carriage Return End of command bit Value dd Function Inte...

Страница 33: ...e baud rate command dd Two characters representing the desired baud rate 12 1200 24 2400 48 4800 96 9600 19 19200 default 38 38400 57 57600 11 115200 CR Carriage Return End of command Response dd CR i...

Страница 34: ...dd CR Delimiter character aa Hexadecimal address of the device 7 Change device baud rate command dd New Hexadecimal address CR Carriage Return End of command Response dd CR if the command was valid Ex...

Страница 35: ...Delimiter character aa Hexadecimal address of the device B Change Byte Level command n Byte to be set n is in the range of 0 3 dd Byte data in hex format CR Carriage Return End of command Response n...

Страница 36: ...irection to become an Input or an Output 0ddd Groups Direction data 1 for Output 0 for Input 00 to 0B CR Carriage Return End of command Response dddd CR if the command was valid Example Command 00PD00...

Страница 37: ...character aa Hexadecimal address of the device PU Sets Pull up source dd Pull ups source data 1 for Vcc 0 for GND 00 to 05 CR Carriage Return End of command Response dd CR if the command was valid Exa...

Страница 38: ...escription This command sets the Auxiliary Relay state Syntax aaSdd CR Delimiter character aa Hexadecimal address of the device S Defines the Auxiliary Relay state dd Auxiliary relay state 10 for Acti...

Отзывы: