IA-2660-Ui
20
www.intelligent-appliance.com
Specifications are subject to change without notice
Isolated TCP/IP
96 Digital TTL/LVTTL
Pluggable Terminal Blocks
?aa5
–
Get Device mode (Register #50)
Description
This command reads the module operation mode
Syntax
?aa5<CR>
?
Delimiter character
aa
Hexadecimal address of the device
5
System Mode command
<CR> Carriage Return - End of command
Response
_dd<CR> if the command was valid
dd
Mode (00-FF)
82
Enable BR change
02
Report on command errors
00
Normal
<CR> Carriage Return - End of command
Example
Command: ?005<CR>
Response: _82<CR>
In this example the module operation mode enables baud rate change.
It will also send error messages for invalid commands.
‘82’ Value must be changed to ‘Normal’ right after BR or Address are
changed.
‘Normal’ can be ‘00’ or ‘02’ or any other preferred value except ‘82’, as
otherwise both the BR or Address might be changed by mistake.