26
INS-500 & INS-1000 • 5403645 • REV A • 6/17
17.
Using a 13/16” wrench loosen the filter bowl from the filter body. See Fig. 32.
18.
After the filter bowl is separated from the filter body, remove the filter element by gently pulling down. See Fig. 34.
19.
Replace the filter element with the correct filter element from the replacement kit (#0090206). See Fig. 35:
a. The filter body (#5230003) all the way to the right is the 5 micron filter which has a GREEN element (#5230012).
b. The filter body (#5230004) second from the right is the 1 micron filter which has a RED element (#5230013).
c. The filter body (#5230005) third from the right is the 0.01 micron filter which has a BLUE element (#5230014).
d. The filter body (#5230006) on the far left is the activated carbon filter which has a BLACK element (#5230015).
Note:
This filter bowl is not connected to the drain and has a black handled valve.
Fig. 33
It is extremely important that you only unscrew the drain bowl from the filter body. The float adjustments
at the bottom must remain in auto. Manual (man) will cause the floats to remain open and air to leak. If
you accidently loosen the float adjustment, simply retighten with your hand. See Fig. 33.
auto
man
Fig. 32
DO NOT
PLACE
WRENCH HERE
CAREFULLY
WRENCH HERE
ONLY
Fig. 34
Fig. 35
Filter Body
Filter Element
Filter Bowl
GREEN (a)
RED (b)
BLUE (c)
BLACK (d)