background image

75

Desactivating outgoing call storage

Lift  the  main  extension  handset,  press 

 +

 

MAIN PASSWORD  + 

,

wait for confirmation tone.

30.14.3 TOLL FREE restriction (Buffer memory full)

Default factiry setting: Feature desactivated.

This feature blocks outgoing calls when the call report buffer memory is full. In this

case only the operator can establish outgoing calls.

Activating the buffer restriction

Lift  the  main  extension  handset,  press 

 +

 

MAIN PASSWORD  + 

,

wait for confirmation tone.

Desactivating the buffer restriction

Lift  the  main  extension  handset,  press 

 +

 

MAIN PASSWORD  + 

,

wait for confirmation tone.

30.14.4 Initialization time for station call report

Default factory setting: 7 seconds.

Setting the PABX waiting time to initiate the call report

Lift the main extension handset, press 

 +

 

MAIN PA 

 + LINE +

 + INITIALISATION TIME (05 to 45 seconds), wait for confirmation tone.

30.14.5 Call attending with polarity inversion

Default factory setting: Without polarity inversion.

Polarity inversion allows for call billing once the call connection has been established.

The  PABX  identifies  when  an  outgoing  call  connection  is  established  through  the

polarity inversion of the line.

Activating polarity inversion

Lift the main extension handset, press 

 

 + MAIN PA 

 + LINE +

, wait for confirmation tone.

Содержание Micro PABX Conecta

Страница 1: ...CONECTA MODULARE i Version handbook 02 07 Compatible Software 6 8...

Страница 2: ...es to suit your commercial and residential needs This manual will guide you through the installation and configuration process of your equipment that will make your daily working environment very plea...

Страница 3: ...1 10 Installing the power supply 13 1 11 Connecting the ground protection 13 1 12 Technical Specifications 15 2 GENERAL CONFIGURATION OF THE PABX 16 2 1 Changing the main password 16 2 2 Command to e...

Страница 4: ...r queue 32 8 CANCELLING PASSWORDS EXTENSION FOLLOW ME DND TOLL FREE RESTRICTION AT ONCE 32 9 INTERCOM EMERGENCY 32 9 1 Setting extension to make an emergency call 32 9 2 Setting extension to receive e...

Страница 5: ...Hotline without delay external line 41 16 2 Hotline with delay external line 41 16 3 Hotline without delay intercom 41 16 4 Hotline with delay intercom 42 17 CALL INTRUSION 42 17 1 Categories 42 17 2...

Страница 6: ...rom the main extension 55 27 FOLLOW ME 55 27 1 Cancelling follow me from the main extension 55 28 TRANSFERRING CALLS 56 28 1 Return of Transfered calls 56 28 2 Transferring a call 56 28 3 Transferring...

Страница 7: ...Description 76 31 2 DISA Configuration 77 32 CALLER ID BOARD 79 32 1 PABX caller ID 79 32 2 Extension caller ID 80 32 3 Remove caller ID category 81 32 4 Received call classification for the Ti KTS 81...

Страница 8: ...87 34 6 Emergency call through an external device 88 34 7 Cancelling the emergency call 89 35 TONE DETECTION BOARD LEAST COST ROUTING 89 35 1 Programming the time table for one carrier 89 35 2 Progra...

Страница 9: ...efully read the following instructions Do not install the equipment in places without ventilation with humidity next to sources of heat or vibrations Avoid installing the PABX in places with intense s...

Страница 10: ...X base drill the hole and then insert the anchor plug Step 2 Hook the PABX base onto the screw head Step 3 Push the PABX base downwards until the screw head fits into the base mount Step 4 Aline the P...

Страница 11: ...CN22 External Activation Board ITA 700 CN23 Doorphone IP 700 J9 Jumper for External or Internal Music CN37 External Music input CN38 External Lines 1 and 2 CN39 Groud Protection CN40 External Lines 3...

Страница 12: ...E I 1 4 Identifying the internal connectors of the Modulare i and Conecta Opening the PABX Press the lateral clips to remove the PABX cover To place the cover again just insert it on top of the base a...

Страница 13: ...rd juntor 3 CN20 CN30 CN32 e CN33 Trunk Board juntor 4 CN21 CN31 CN34 e CN35 J4 Battery Jumper J5 Jumper for 12V J6A and J6B activate lines 1 and 2 J7A and J7B Polarity inversion for Line 1 and 2 J8A...

Страница 14: ...6 CONECTA...

Страница 15: ...closed 2 Reset Jumper J3 Jumper 5V J4 Jumper for battery J5 Jumper 12V J6A and J6B enable lines 1 and 2 J7A and J7B polarity inversion for line 1 and 2 J8A and J8B Adjust ring sensor for line 1 and 2...

Страница 16: ...ious extensions in the same conduit keep the wires far from the electrical network or electronic devices 1 5 1 Existing pre installed extensions sockets 1 5 2 No preexisting installation You will need...

Страница 17: ...extension boards and for 12 extensions 3 extensions boards are required Note The conecta is supplied with 2 extension boards Remove the wire insulation and press the connector clip CN 36 downwards In...

Страница 18: ...call using a regular telephone connected to the telephone line in mode Tone If the call is established your line has a multifrequencial signal Tone in such case you can use your PABX without any confi...

Страница 19: ...line 3 4 and press down the conector s crank CN 40 Insert the wires and release the crank Line 3 Remove jumper CN 32 and install the trunk board in the slots CN20 CN30 CN 32 e CN33 If after installin...

Страница 20: ...you want your PABX to use polarity inversion you need to close the jumper J7 A for line 1 and J7 B for line 2 For line 3 and 4 close jumper J2 of the trunk board corresponding to the line See Using P...

Страница 21: ...t that permits the deviation of the electrical current field to earth This conductor is available in electrical or electronic equipment stores Verify the voltage of your electrical network position th...

Страница 22: ...s any other equipment connected to the PABX avoiding current movement between them NOTE Connect the grounding wire of the power supply to CN39 whether you have grounding or not Maximum grounding resis...

Страница 23: ...n is done Sinaling Decadic DC and multifrequence MF Line Reach 2000 ohms for lines and 1100 ohms for extensions including the telephone Electrical Protection Available whitin the trunks and Power Supp...

Страница 24: ...press GENERAL PASSWORD From this moment you can program each feature of your PABX following the instructions Exiting PABX program mode Place the main extension handset on the hook 2 2 1 Main Extension...

Страница 25: ...0 This program feature will define the signaling mode used by the PABX You can also block a line or transform it into an internal enlace How to indetify your telephone line signal Before connecting yo...

Страница 26: ...unk If one of the external line positions is not used you can transform it into an internal path to improve the functionality of your PABX Lift handset press MAIN PASSWORD 3 digits LINE wait for confi...

Страница 27: ...ion with its physical position PABX extension connectors The physical position is not flexible while the extension numbering varies as per necessity Altering the extension number setting Lift handset...

Страница 28: ...ensions regardless of category TIME TABLE 0 Programmed prefix does not use the carriers time table 1 Programmed prefix uses time table 1 requires tone detection board 2 Programmed prefix uses time tab...

Страница 29: ...external calls programmed for each extensions Setting the PABX not to analyze the access code table Lift handset press MAIN PASSWORD LINE wait for confirmation tone Setting the PABX to analyze the ac...

Страница 30: ...rmation tone Example You want to prevent all lines from receiving collect calls during nightmode While in main programming press 4 9 831 2 10 Auto answer Factory setting Extension 20 programmed to aut...

Страница 31: ...ine operator in night mode Lift handset press MAIN PASSWORD LINE EXTENSION NO wait for confirmation tone Setting a group as line operator in night mode Lift handset press MAIN PASSWORD LINE GROUP NO 1...

Страница 32: ...r Factory setting Extension 21 You can determine an extension or a group to answer incoming calls in case they are not answerd by the extension or nightmode service The call will ring on this extensio...

Страница 33: ...all incoming calls ringing for 70 seconds on the extension operator before diverting the call Enter in PABX program mode and press 4 9 4 70 2 10 6 Ring overflow for night mode Factory setting Activat...

Страница 34: ...can also define that after this time your PABX can consider the call as through or drop it The Dial Tone Time DTT will be equivalent to 5 times the value used in the program setting Example If you pro...

Страница 35: ...ephone connected directly to the telephone line 3 1 Category for fast internet access Setting extensions for fast internet access Lift handset press MAIN PASSWORD EXTENSION NO referring to physical po...

Страница 36: ...ave external access independantly from its external call category local regional DDD or IDD Example Your extension can have a category for local calls and also be categorized to access a long distance...

Страница 37: ...NO 20 to 99 wait for confirmation tone 4 3 Using both phone directories Press STORED NUMBER POSITION 20 to 99 after dial tone press FLASH If your have decadic signal press instead of FLASH 5 INDIVIDU...

Страница 38: ...on set with call barring receives internal dial tone with signal continuous tone followed by beeps at each second If the extension was set with a barring category it will not accept another program se...

Страница 39: ...wait for confirmation tone 6 3 Cancelling any TOLL RESTRICTION From main extension lift handset press MIAN PASSWORD 3 digits EXTENSION NO wait for confirmation tone 7 CALL CAPTURE You can capture una...

Страница 40: ...8 CANCELLING PASSWORDS EXTENSION FOLLOW ME DND TOLL FREE RESTRICTION AT ONCE Lift handset press MAIN PASSWORD EXTENSION N wait for confirmation tone 9 INTERCOM EMERGENCY Factory setting No emergency...

Страница 41: ...munication You can set up to 4 groups as follows 1 boss and 1 secretary 1 boss and 2 secretaries 2 bosses and 1 secretary and 2 bosses and 2 secretaries 10 1 Setting the group and the position of each...

Страница 42: ...boss Two bosses and one secretary The secretary presses to call boss 1 and to boss 2 Both bosses press to call the secretary Two bosses and two secretaries The bosses call secretary 1 by pressing and...

Страница 43: ...rally happens with cordless telephones other telephone brands or fax machines Your extension flash time must be higher than of your telephone otherwise when using this feature the call will be disconn...

Страница 44: ...From main extension lift handset and press MAIN PASSWORD wait for confirmation tone Desactivating conference call From main extension lift handset and press MAIN PASSWORD wait for confirmation tone E...

Страница 45: ...arties at the same time Press FLASH To put the second party on hold and talk to the first one Press FLASH To remove the last party Press FLASH 13 CALL DIVERT This feature will allow for incoming calls...

Страница 46: ...xtension groups forwarder or hierarchic From your extension lift handset press N OF RINGS 3 to 7 EXTENSION N wait for confirmation tone Setting a group to answer your calls From your extension lift ha...

Страница 47: ...all is forwarded to the next available extension Example Suppose you have programmed the extension sequence 23 25 e 27 for a group forwarder and the last incoming call was forwarded to extension 25 th...

Страница 48: ...ng forwarded to the group From the main extension lift handset press MAIN PASSWORD GROUP N 1 2 3 or 4 N OF RINGS 3 to 7 TYPE OF GROUP 1 forwarder 2 hierarchic and 3 multiple ring wait for confirmation...

Страница 49: ...seconds before accessing the external line You can make any call with in the 7 seconds Activating Hotline From your extension lift handset press ROUTE NO 0 to 4 wait for confirmation tone Desactivati...

Страница 50: ...RUSION Factory setting No setting This feature allows you to break into call on another extension This is useful when there is an emergency when a boss is calling or for telemarketing 17 1 Categories...

Страница 51: ...arketing Factory setting All extensions are desactivated This function allows you to program an extension not to receive beeps during a call intrusion This is done from the selected extension Lift han...

Страница 52: ...call directly the PABX operator press Establishing a chained call to a group You call an extension that is busy to call a group press GROUP N 1 to 4 Establishing a chained call to an extension You ca...

Страница 53: ...sion category for external call Press YOUR EXTENSION PASSWORD and N wait for dial tone EXTERNAL N Example Your extension 22 with password 35 is set as category 3 If you are on another extension catego...

Страница 54: ...blish and receive calls in multifrequencial mode From main extension lift handset press MAIN PASSWORD LINE ROUTE 1 to 4 wait for confirmation tone 19 4 2 External call category through special route F...

Страница 55: ...t mode From main extension lift handset press MAIN PASSWORD CATEGORY EXTENSION N wait for confirmation tone CATEGORIA 0 No access to route 3 and 4 1 No access to route 3 2 No access to route 4 3 Acces...

Страница 56: ...m main extension lift handset press MAIN PASSWORD ROUTE 1 to 4 EXTENSION N wait for confirmation tone Day and night mode From main extension lift handset press MAIN PASSWORD ROUTE 1 to 4 EXTENSION N w...

Страница 57: ...9 EXTENSION N wait for confirmation tone Cancelling the private code From main extension lift handset press MAIN PASSWORD PRIVATE CODE 00 to 39 wait for confirmation tone 19 6 2 Registering a password...

Страница 58: ...ST NUMBER DIALED MEMORY Redialing last number using multifrequencial telephone Press or After the dial tone press FLASH Redialing last number using decadic telephone Press or After the dial tone press...

Страница 59: ...confirmation tone Desactivating DND From your extension lift handset press wait for confirmation tone Important Before activating this feature you need to have a password for your extension See 17 2 o...

Страница 60: ...ut on hold and you are through the second call To swing between calls Press FLASH To transfere the call to the extension you inquired Put the phone on the hook To end and inquiry and the external call...

Страница 61: ...r extension will be called back when the external line is available 25 2 Recalling a busy or unavailable extension Extension unavailable While receiving the line tone press or wait for confirmation to...

Страница 62: ...busy line Lift your extension handset press wait for confirmation tone 25 4 Number of rings to wait before programming the recall Factory setting Number of rings equals zero From main extension press...

Страница 63: ...ME Programming an extension to answer all your calls Lift the extension handset press YOUR EXTENSION PASSWORD AND N wait for confirmation tone Desactivating Lift your extension handset press wait for...

Страница 64: ...ess FLASH and disconnect 28 4 Transferring a call to an extension group Press FLASH GROUP N 1 to 4 and disconnect 28 5 Transferring a call using the private code Activating the private code Before ent...

Страница 65: ...feature Lift the main extension handset press MAIN PASSWORD wait for confirmation tone Example To activate the access enter in main programming press 281 28 6 1 Using the SPC feature during an extern...

Страница 66: ...ely Installing the Communication board Installing the serial device Station Call Report A report can be printed using the following connector CN41 DB25 DB9 Printer Printer TXDB Pin 3 Pin 2 DCDB Pin 20...

Страница 67: ...alled with the Modular Conecta is four 4 TI 630 or TI 730i Installing your Ti Install the communication board The data wire is connected to CN41 and should be seperate from the audio wiring Install a...

Страница 68: ...2 3 short lines low sensibility Adjust the position of the jumper J4 of the trunk boards and J11 A B of the main board IC For the ID board to function properly the programming steps in item 32 should...

Страница 69: ...to 68 HDL individual F3A F4A F5A F7 F8 e HDL Coletivo modelo MP Thevear individual NR85 NR90 NR100 NR110 NR200 NR210 Thevear traditional model e V deo Porteiro HDL Conect the interface to CN23 Follow...

Страница 70: ...and CN 49 See 2 6 and 36 for proper programming and operation 29 5 Electronic doorphone PI100 To install the PI 100 just connect the wires to an extension See 34 on how to prgram the PI 100 29 6 Tone...

Страница 71: ...peration The communication board is required if an external number is programmed to answer the emergency call 29 7 External activation interface ITA 700 The ITA 700 allows you to control an external d...

Страница 72: ...irmation tone WEEK DAY 1 sunday 2 monday 3 tuesday 4 wednesday 5 thursday 6 friday 7 saturday Setting the time Lift the main extension handset press MAIN PASSWORD TIME 00 to 23 MINUTE 00 to 59 SECOND...

Страница 73: ...reminder from the main extension Reminder for the next time Lift the main extension handset press HOUR 00 to 23 MINUTE 00 to 59 EXTENSION NO wait for confirmation tone Reminder daily at the same time...

Страница 74: ...ation tone 30 4 Setting the working hours for Saturday Default factory setting All saturdays are set as holiday Setting the interval of the day as working hours Lift the main extension handset press M...

Страница 75: ...ress MIAN PASSWORD wait for confirmation tone Setting Automatic night mode service for week days Lift the main extension handset press MIAN PASSWORD wait for confirmation tone Desactivating night mode...

Страница 76: ...ill be disconnected at 17 45 00 Seting the maximum time for outgoing calls Lift the main extension handset press MAIN PASSWORD MINUTES 01 to 59 EXTENSION N o wait for confirmation tone To reset Lift t...

Страница 77: ...rmation tone 30 10 2 Calling a PABX with auto answer Using a decadic phone wait for your call to be answer by the extension programmed as attendant the decadic mode does not allow for direct access to...

Страница 78: ...direct calls Blocking direct incoming calls Lift your extension handset press wait for confirmation tone Releasing direct incoming calls Lift your extension handset press wait for confirmation tone 30...

Страница 79: ...ency call to an external number Default factory setting No emergency call programmed This feature allows you to program an extension to automatically establish emergency calls When the programmed exte...

Страница 80: ...rmation tone Important You can program the time and the number of times to redial the external number The following shows how o program this feature 30 13 1 Time interval between each redial Default f...

Страница 81: ...wered With the caller ID board the incoming call number is shown The designation ID is shown in the extension column in case the call report feature is activated before the call is transferred see 30...

Страница 82: ...e of unanswered calls Lift the main extension handset press MAIN PASSWORD wait for confirmation tone 30 14 1 3 PABX incoming calls before transfer Activating the storage of unanswered calls Lift the m...

Страница 83: ...set press MAIN PASSWORD wait for confirmation tone 30 14 4 Initialization time for station call report Default factory setting 7 seconds Setting the PABX waiting time to initiate the call report Lift...

Страница 84: ...ess MAIN PASSWORD LINE wait for confirmation tone If the caller enter the wrong number or simly does not enter any number after the auto answer the PABX will disconnect the call Desactivating auto ans...

Страница 85: ...UP 1 to 4 for extensions group Press to enable external activation Press MAIN PASSWORD DESIRED PROGRAMMING CODE for remote programming Remote programming can only be done after changing the PABX main...

Страница 86: ...ssage Lift the main extension handset press wait for confirmation tone Desactivating Lift the main extension handset press wait for confirmation tone Activating NIGHT MODE factory message Lift the mai...

Страница 87: ...mation tone 31 2 3 Setting the menu This feature allows the PABX to understand the codes for direct access to groups Activating the menu Lift the main extension handset press wait for confirmation ton...

Страница 88: ...INE wait for confirmation tone 32 2 Extension caller ID An extension will only receive the caller ID when the call rings the extension might belong to a group forwarder hierarchic multiple and sequenc...

Страница 89: ...mming prompt To cancel From main extension lift handset off hook press 12 MAIN PASSWORD 3 digits 3020 wait for programming prompt Note The above applies to all extensions 32 4 Received call classifica...

Страница 90: ...SION N wait for confirmation tone 33 ELECTRONIC DOORPHONE Note If you install a PI 100 and replace it by another doorphone that requires an interface IP 700 you should desactivate the installation and...

Страница 91: ...following instructions should be followed Programming the physical position Lift the main extension handset press MAIN PASSWORD PHYSICAL POSITION 11 wait for confirmation tone 33 3 Desactivating an i...

Страница 92: ...xtension handset press MAIN PASSWORD TIME TO ACTIVATE THE ATTENDAND 15 to 90 sec wait for confirmation tone Once done you need to program the extensions to ring sequentially extension 20 21 22 23 and...

Страница 93: ...7 Activating the doorphone attendant Default factory setting extension 20 After programming the attendant you will use this feature to enable an extension group or external number as doorphone attend...

Страница 94: ...d use broker call to keep the external call 33 8 3 Programming the time to activate the door Factory setting 1 second Lift the main extension handset press MAIN PASSWORD TIME 1 to 5 sec wait for progr...

Страница 95: ...n extension handset press MAIN PASSWORD TIME 00 to 20 seconds wait for confirmation tone 34 5 Automatic external activation This feature allows to automatically command an external activation such as...

Страница 96: ...TERNAL NO wait for confirmation tone NOTE When the call is answered beeps will be emitted during 60 seconds defining the time limit for this type of calls If the DISA board is installed you receive a...

Страница 97: ...ged 35 TONE DETECTION BOARD LEAST COST ROUTING This feature is only available for the Modulare i Two time tables can be programmed during the 24 hours 00 to 23 specifying the carrier you want to use i...

Страница 98: ...ME TABLE 1 or 2 CARRIER CODE HOUR 00 to 23 from the starting time of the command HOUR 00 to 23 from the final time of the command wait for confirmation tone NOTE When you set the final time you should...

Страница 99: ...e Example Intelbras Thanks for calling Press Press Press Press Press 4 for commercial department department department department department Press Press Press Press Press 5 for Finance department depa...