Hardware Installation and User’s Guide
17
Hardware Installation
J1
-
IOP mode select jumper block
: This jumper is used to place the IOP in reset, which
enables the flash chip to be programmed to recover resident firmware (FW). See
for a detailed description of jumper J1.
J4
-
PCI bus speed
:
Leave this jumper in the default position (pins 2-3 to auto-negotiate
33/66 Mhz) unless instructed to do otherwise by customer support or a specification
update.
2.2
Diagnostic Features
The SRCS14L has LED indicators, an 80db audible alarm, and boot-up beep sequences
that can help diagnose the controller.
2.2.1
LED Indicators
The LEDs on the controller indicate SATA activity, data transfer, power status, PCI bus
frequency, and reset mode.
Table 2-1. Controller Jumper Settings
Jumper Block
Jumper Position
Definition
J1
Jumper on pins [1-2]
IOP is in reset mode with firmware recovery
enabled.
Jumper on pins [2-3]
IOP is in normal run mode.
No jumpers
IOP is in normal run mode.
J4
Jumper on pins [1-2]
PCI bus is forced to 33 MHz.
Jumper on pins [2-3]
PCI bus auto-negotiates 33 MHz or 66 MHz.
No jumpers
PCI bus auto-negotiates 33 MHz or 66 MHz.
Figure 2-4. LED Labels and Colors
A:0 A:1
T
S
P66
P
green
yellow
yellow
green
red
green
yellow
yellow
yellow
B:0 B:1