18
Hardware Installation and User’s Guide
Hardware Installation
2.2.2
Audible Alarm
An 80db audible alarm, which is controlled by the RAID firmware, is mounted on the
RAID controller to indicate any of the following events:
•
State of controller upon boot-up
•
Change in the normal state of the array
•
Change of controller environmental status (during normal operation)
•
Failure of hardware that the controller manages
If the cause of the event is resolved and/or removed, the audible alarm will cease. You can
also turn off the audible alarm manually through StorCon or . If you use these
management tools to silence the alarm, it will only be disabled for the current event and
will be ready to sound again at the next event.
2.2.2.1
Silencing the Audible Alarm in StorCon
In StorCon, under Advanced Setup > Configure Controller, press <F4> to silence alarm.
Note: The <F4> option is only available if the alarm has been activated.
2.2.2.2
Silencing the Audible Alarm in
In , in the
Physical Configuration
view, right click on the icon of the controller
requiring alarm deactivation. Click
Silence
to deactivate alarm. If the alarm has not been
activated, the
Silence
option will be grayed out.
Table 2-2. LED Descriptions
LED
Description
A:0
Indicates activity on SATA port A:0.
A:1
Indicates activity on SATA port A:1.
B:0
Indicates activity on SATA port B:0.
B:1
Indicates activity on SATA port B:1.
T
Indicates data transfer to the controller’s cache memory.
S
When illuminated, the controller's IOP is in reset mode.
P
When illuminated, the controller card is powered on.
P66
When illuminated, PCI bus frequency is 66Mhz. When not illuminated, PCI bus
frequency is 33Mhz.