Cannot Connect to a Server
•
Make sure the network cable is securely attached to the correct connector at the
system back panel.
•
Try a different network cable.
•
Make sure you are using the correct and the current drivers. See
“Server System
References”
for a link to the current drivers.
•
Make sure the driver is loaded and the protocols are bound.
•
Make sure the hub port is configured for the same duplex mode as the network
controller.
•
Make sure the correct networking software is installed.
•
If you are directly connecting two servers (without a hub), you will need a crossover
cable.
•
Check the network controller LEDs next to the NIC connectors.
Problems with Network
The server hangs when the drivers are loaded
•
Certain drivers may require interrupts that are not shared with other PCI drivers. For
these drivers, it may be necessary to alter settings so that interrupts are not shared.
See the documentation that came with your PCI card(s) for information on changing
interrupts.
Diagnostics pass but the connection fails
•
Make sure the network cable is securely attached.
•
Make sure you specify the correct frame type in your NET.CFG file.
•
The controller stopped working when an add-in adapter was installed.
•
Make sure the cable is connected to the port from the onboard network controller.
•
Make sure your BIOS is current. See
“Server System References”
for a link to the
current version.
•
Make sure the other adapter supports shared interrupts. Make sure your operating
system supports shared interrupts.
•
Try reseating the add-in adapter.
The add-in adapter stopped working without apparent cause
•
Reseat the adater.
•
Put the adapter in a different slot.
Содержание SR1500AL - Server System - 0 MB RAM
Страница 3: ...Intel Server System SR1500AL User s Guide iii ...
Страница 4: ...iv Intel Server System SR1500AL User s Guide ...
Страница 8: ...viii Intel Server System SR1500AL User s Guide ...
Страница 12: ...xii Intel Server System SR1500AL User s Guide ...
Страница 22: ...xxii Intel Server System SR1500AL User s Guide ...
Страница 42: ...20 Intel Server System SR1500AL User s Guide ...
Страница 51: ...Intel Server System SR1500AL User s Guide 29 Figure 20 Removing the Processor Air Duct TP02201 ...
Страница 106: ...84 Intel Server System SR1500AL User s Guide ...
Страница 118: ...96 Intel Server System SR1500AL User s Guide ...
Страница 132: ...110 Intel Server System SR1500AL User s Guide ...
Страница 144: ...122 Intel Server System SR1500AL User s Guide ...
Страница 156: ...134 Intel Server System SR1500AL User s Guide ...
Страница 180: ...158 Intel Server System SR1500AL User s Guide ...