78
Intel
®
Server System SR1500AL User’s Guide
Figure 64. Clear CMOS Jumper
4. Wait five seconds.
5. Return the CMOS Clear jumper to the CMOS Clear by BMC location, covering
pins 1 and 2.
6. Close the server chassis.
7. Reconnect the AC power and power up the system.
8. The CMOS is now cleared and can be reset by going into the BIOS setup.
TP02080
3
2
Password
Reset
J1D2
J1D3
3
2
Clear
CMOS
BMC Force
Update Mode
3
2
J1D1
Disable
Enable