Intel
®
Server System SR1500AL User’s Guide
137
Power and Electrical Warnings
Caution: The power button, indicated by the stand-by power marking, DOES NOT completely turn
off the system AC power, 5V standby power is active whenever the system is plugged in.
To remove power from system, you must unplug the AC power cord from the wall outlet.
Your system may use more than one AC power cord. Make sure all AC power cords are
unplugged. Make sure the AC power cord(s) is/are unplugged before you open the
chassis, or add or remove any non hot-plug components.
Do not attempt to modify or use an AC power cord if it is not the exact type required. A
separate AC cord is required for each system power supply.
Some power supplies in Intel
®
servers use Neutral Pole Fusing. To avoid risk of shock use
caution when working with power supplies that use Neutral Pole Fusing.
The power supply in this product contains no user-serviceable parts. Do not open the
power supply. Hazardous voltage, current and energy levels are present inside the power
supply. Return to manufacturer for servicing.
When replacing a hot-plug power supply, unplug the power cord to the power supply
being replaced before removing it from the server.
To avoid risk of electric shock, turn off the server and disconnect the power cord,
telecommunications systems, networks, and modems attached to the server before opening
it.
Power Cord Warnings
If an AC power cord was not provided with your product, purchase one that is approved
for use in your country.
Caution: To avoid electrical shock or fire, check the power cord(s) that will be used with the
product as follows:
•
Do not attempt to modify or use the AC power cord(s) if they are not the exact type
required to fit into the grounded electrical outlets
•
The power cord(s) must meet the following criteria:
•
The power cord must have an electrical rating that is greater than that of the
electrical current rating marked on the product.
•
The power cord must have safety ground pin or contact that is suitable for the
electrical outlet.
•
The power supply cord(s) is/are the main disconnect device to AC power. The socket
outlet(s) must be near the equipment and readily accessible for disconnection.
•
The power supply cord(s) must be plugged into socket-outlet(s) that is /are provided
with a suitable earth ground.
Содержание SR1500AL - Server System - 0 MB RAM
Страница 3: ...Intel Server System SR1500AL User s Guide iii ...
Страница 4: ...iv Intel Server System SR1500AL User s Guide ...
Страница 8: ...viii Intel Server System SR1500AL User s Guide ...
Страница 12: ...xii Intel Server System SR1500AL User s Guide ...
Страница 22: ...xxii Intel Server System SR1500AL User s Guide ...
Страница 42: ...20 Intel Server System SR1500AL User s Guide ...
Страница 51: ...Intel Server System SR1500AL User s Guide 29 Figure 20 Removing the Processor Air Duct TP02201 ...
Страница 106: ...84 Intel Server System SR1500AL User s Guide ...
Страница 118: ...96 Intel Server System SR1500AL User s Guide ...
Страница 132: ...110 Intel Server System SR1500AL User s Guide ...
Страница 144: ...122 Intel Server System SR1500AL User s Guide ...
Страница 156: ...134 Intel Server System SR1500AL User s Guide ...
Страница 180: ...158 Intel Server System SR1500AL User s Guide ...