![Intel SBCEFCSW Скачать руководство пользователя страница 26](http://html1.mh-extra.com/html/intel/sbcefcsw/sbcefcsw_installation-manual_2072037026.webp)
12
Intel® Server Switch Module SBCEFCSW: Installation Guide
Complete the following steps to install a switch module:
1.
Review the information in “Safety and regulatory information” on page v
through
“Handling static-sensitive devices” on page 10
2.
Remove the acoustic attenuation module option, if necessary, from the rear of the SBCE unit. See the
Intel
®
Server Compute Blade SBXL52: Installation and User’s Guide for detailed removal instructions.
Figure 3. Removing the acoustic attenuation module
3.
Be sure that the SBCE unit is turned on, the green DC power LED on each power module is lit, and the
green OK LED on the management module is lit.
4.
Select only switch-module bay 3 or bay 4 in which to install the switch module.
5.
Remove the filler module from the switch-module bay in which you are installing the switch module.
Store the filler module for future use.
✏
NOTE
Install your switch module only in switch-module bay 3 or bay 4.
6.
If you have not already done so, touch the static-protective package that contains the switch module to an
unpainted metal part of the
SBCE
unit for at least 2 seconds.
7.
Remove the switch module from its static-protective package.
Содержание SBCEFCSW
Страница 4: ...iv Intel Server Switch Module SBCEFCSW Installation Guide...
Страница 14: ...xiv Intel Server Switch Module SBCEFCSW Installation Guide...
Страница 22: ...8 Intel Server Switch Module SBCEFCSW Installation Guide...
Страница 30: ...16 Intel Server Switch Module SBCEFCSW Installation Guide...
Страница 34: ...20 Intel Server Switch Module SBCEFCSW Installation Guide...
Страница 56: ...42 Intel Server Switch Module SBCEFCSW Installation Guide...
Страница 58: ...44 Intel Server Switch Module SBCEFCSW Installation Guide...