![Intel SBCEFCSW Скачать руководство пользователя страница 18](http://html1.mh-extra.com/html/intel/sbcefcsw/sbcefcsw_installation-manual_2072037018.webp)
4
Intel® Server Switch Module SBCEFCSW: Installation Guide
•
Humidity:
— Operating: 25% to 80%,
noncondensing
— Non-operating: 25% to
90%, noncondensing
Switch regulatory certifications:
Electrical:
•
Power source loading: 3.75
amps maximum at 12 V dc
•
Heat output: 45 watts
maximum
•
Operating voltage:
12 V dc
•
Circuit protection: Internally
fused
•
Safety standards:
— UL 1950 (USA)
— UL 1950 (Canada)
— EN60950 (EC)
— Support for Japan
— Support for Korea
— CB scheme - IEC 60950
•
Emissions standards:
FCC part 15B Class A (USA)
— VCCI Class A ITE
(Japan)
— ICES-003 issue 3
(Canada)
— A4EN55022 level A
(EC)
— Voltage fluctuations:
EN 61000-3-3
— Harmonics: EN 61000-3-
2
— Immunity: EN55024:
1998
— Marking:
–
FCC Part 15
–
UL (United States)
–
cUL (Canada)
–
TUV
–
VCCI
–
CE
Shortwave laser SFP module at 1
Gbps and multi-mode SFP module
at 2 Gbps:
•
Connector: LC-LC
•
Color coding: Beige or black
exposed connector surfaces
•
Cable: Fibre Channel 100-
M6-SN-I (50
µ
m multimode)
•
Wavelength: 830 to 860 nm
•
Transmit power: -10 dBm
minimum
•
Receiver sensitivity: -16 dBm
average
•
Distance:
— 500 meters maximum
using 50 micron fiber
— 300 meters maximum
using 62.5 micron fiber
•
Safety: DHHS 21 CFR(J),
IEC 825-1 CENCELEC EN
60825-1, VDE
Longwave laser SFP module at 1
Gbps and 2 Gbps single-mode:
•
Connector: LC-LC Fibre
Channel cable
•
Color coding: Blue exposed
connector surfaces
•
Cable: Fibre Channel
100SM-LC-L (9
µ
m single
mode)
•
Wavelength:
1270 through 13.5 nm
•
Transmit power: -10 dBm
minimum
•
Receiver sensitivity: -20 dBm
average
•
Distance: 2 meters to 10
kilometers
•
Safety: DHHS 21 CFR(J),
IEDC 825-1 CENELEC EN
60825-1, VDE
Table 1. Fibre Channel switch module specifications (continued)
Содержание SBCEFCSW
Страница 4: ...iv Intel Server Switch Module SBCEFCSW Installation Guide...
Страница 14: ...xiv Intel Server Switch Module SBCEFCSW Installation Guide...
Страница 22: ...8 Intel Server Switch Module SBCEFCSW Installation Guide...
Страница 30: ...16 Intel Server Switch Module SBCEFCSW Installation Guide...
Страница 34: ...20 Intel Server Switch Module SBCEFCSW Installation Guide...
Страница 56: ...42 Intel Server Switch Module SBCEFCSW Installation Guide...
Страница 58: ...44 Intel Server Switch Module SBCEFCSW Installation Guide...