Configurable Fabric Address Notification
Fabric Address Notification (FAN), as described in FC-FLA, is sent out by the fabric after an initialization
event (usually a loop initialization port) to each attached NL_Port. The purpose of the FAN is to inform
the attached NL_Ports of the fabric node name, port name, and fabric address.
The following information is a summary of the specifications of the switch module:
Table 1. Fibre Channel switch module specifications
Fibre Channel switch module
specifications:
•
Fibre Channel protocols:
FC-PH version 4.3, FC-PH-2,
FC-PH-3, FC-AL version 4.5,
FC-AL-2 Rev 7.0, FC-FLA,
FC-GS-3, FC-FG, FC-PLDA,
FC-Tape, FC-VI, FC-SW-2,
Fibre Channel Element MIB
RFC 2837, and Fibre Alliance
MIB version 4.0.
•
Fibre Channel service classes:
Class 2 and class 3
•
Operation modes
:
Fibre
Channel class 2 and class 3,
connectionless.
•
External port type: Generic
loop port (GL_port)
•
Internal port type:
fabric port
(F_port)
•
Port characteristics:
External
ports are automatically
detected and self configuring
•
Number of
Fibre Channel
ports: 2 external ports and 14
internal ports
•
Scalability: 239 switches
maximum depending on your
configuration
•
Maximum number of user
ports: 475 000 ports
depending on your
configuration
•
Buffer credits: 12 buffer
credits per port
•
Media type: Small form-
factor pluggable (SFP)
module
•
Fabric port speed: 1.0625 or
2.125 Gbps (gigabits per
second)
•
Maximum frame size
:
2148
bytes (2112 byte payload)
•
System processor: Geode
SC1200
•
Fabric latency: Less than 0.5
µ
sec
•
Fabric point-to-point
bandwidth: 2 Gbps or 4 Gbps
at full duplex
•
Fabric aggregate bandwidth:
64 Gbps at full duplex
•
Nonblocking architecture to
prevent latency
Switch maintainability:
•
Diagnosis: Power-on self-test
(POST) is performed on all
functional components except
the SFP module. Port
operational tests include
internal, external, and online
tests.
•
User interface: LED
indicators
Fabric management:
•
Management methods:
— SAN Utility application
— Telnet and command line
interface (CLI)
•
Switch SNMP agent: Enables
a network management
workstation to receive
configuration values, traffic
information, and Fibre
Channel failure data through
SNMP and the Ethernet
interface.
Dimensions:
•
Width: 112 mm (4.41 in.)
•
Height: 29 mm (1.14 in.)
•
Depth: 260.3 mm (10.25 in.)
•
Weight: 2 lb
Environmental:
•
Temperature and altitude:
— Operating:
5
°
C to 40
°
C
(41
°
F to 104
°
F) at an
altitude of 0 to 3048 m
(0 to 10 000 ft.)
— Non-operating:
-40
°
C to 65
°
C
(-40
°
F to 149
°
F) at an
altitude of 0 to 15
240 m (0 to 50 000 ft.)
Содержание SBCEFCSW
Страница 4: ...iv Intel Server Switch Module SBCEFCSW Installation Guide...
Страница 14: ...xiv Intel Server Switch Module SBCEFCSW Installation Guide...
Страница 22: ...8 Intel Server Switch Module SBCEFCSW Installation Guide...
Страница 30: ...16 Intel Server Switch Module SBCEFCSW Installation Guide...
Страница 34: ...20 Intel Server Switch Module SBCEFCSW Installation Guide...
Страница 56: ...42 Intel Server Switch Module SBCEFCSW Installation Guide...
Страница 58: ...44 Intel Server Switch Module SBCEFCSW Installation Guide...