Intel® Storage Server System JBOD2312S3SP Hardware Guide
17
Table 8. Hot-swap Backplane Power Connector Pin-out (“HSBP PWR”)
Pin
Signal Description
Pin
Signal Description
1
Ground
5
P12V_240VA
2
Ground
6
P12V_240VA
3
Ground
7
P12V_240VA
4
Ground
8
P12V_240VA
4.4
Power Supply Module Efficiency
The following table provides the required minimum efficiency level at various loading conditions. These are
provided at four different load levels: 100%, 50%, 20%, and 10%. Efficiency is tested over an AC input
voltage range of 115 VAC to 220 VAC.
Table 9. 460 Watt Power Supply Efficiency
Loading
100% of Maximum
50% of Maximum
20% of Maximum
10% of Maximum
Minimum efficiency
88%
92%
88%
80%
4.5
AC Power Cord Specification Requirements
The AC power cord used meets the specification requirements listed in the following table.
Table 10. AC Power Cord Specifications
Cable Type
SJT
Wire Size
16 AWG
Temperature Rating
105ºC
Amperage Rating
13 A
Voltage Rating
125 V
Figure 20. AC Power Cord
4.6
AC Input Specifications
4.6.1
Power Factor
The power supply meets the power factor requirements stated in the Energy Star Program Requirements for
Computer Servers. These requirements are stated below.