background image

Intel® Storage Server System JBOD2312S3SP Hardware Guide 

 

 

 

2

 

Product Family Overview 

The Intel

®

 Storage System JBOD2312S3SP offers the flexibility of adding additional storage to an existing 

server system with support for 12Gb/s SAS or SATA hard disk drives or SSDs, redundant fan power and 

power options, and SES communication with the server to monitor the health of the JBOD subsystems. 

This chapter provides a high-level overview of the detail for each major system components and features 

provided in the following sections. 

 

Figure 1. 12 x 3.5” Drive JBOD2000S3 Product Drawing 

 

 

Содержание JBOD2312S3SP

Страница 1: ...orage System JBOD2312S3SP Hardware Guide A document providing a system level overview of product features functions architecture and support specifications Revision 1 3 Mar 2016 Intel Server Boards and Systems ...

Страница 2: ... This page is intentionally left blank ...

Страница 3: ......

Страница 4: ...November 2014 0 9 Pre production release December 2014 1 0 Production version release May 2015 1 1 Removed references to PSU Cold Redundancy support October 2015 1 2 Added optional PSU and power cable references in the Power Subsystem section March 2016 1 3 Converted to the new format ...

Страница 5: ... or usage in trade This document contains information on products services and or processes in development All information provided here is subject to change without notice Contact your Intel representative to obtain the latest Hardware Guide The products and services described may contain defects or errors known as errata which may cause deviations from published specifications Current characteri...

Страница 6: ...bution Board PDB 12 4 2 Mechanical Overview 14 4 3 Power Connectors 16 4 3 1 Power Supply Module Card Edge Connector 16 4 3 2 Hot Swap Backplane Power Connector 16 4 4 Power Supply Module Efficiency 17 4 5 AC Power Cord Specification Requirements 17 4 6 AC Input Specifications 17 4 6 1 Power Factor 17 4 6 2 AC Input Voltage Specification 18 4 6 3 AC Line Isolation Requirements 18 4 6 4 AC Line Dro...

Страница 7: ...Power Supply Module Fan 26 6 JBOD2000S3SP Internal Connection Overview 27 6 1 Expander Board 27 6 1 1 JBOD SAS Expander Port Numbering 29 6 1 2 JBOD2312S3SP Interconnection 30 7 JBOD2000S3SP External SAS Connection Mode Overview 31 7 1 External SAS Controller Support 31 7 2 External SAS Cable 31 7 3 Hard Drive Type 32 7 4 JBOD Cascade 32 7 5 Single port JBOD2000S3SP External Connection Mode 32 7 5...

Страница 8: ...ower Supply Assembly 11 Figure 14 Power Distribution Board PDB 12 Figure 15 PDB Component Placement 13 Figure 16 Fan Fault LED Block Diagram 14 Figure 17 Power Supply Module Mechanical Drawing 15 Figure 18 Power Supply Module 15 Figure 19 AC Power Supply Connector View 15 Figure 20 AC Power Cord 17 Figure 21 System Fan Identification 24 Figure 22 System Fan Assembly 25 Figure 23 Internal SAS Expan...

Страница 9: ...or Pin out HSBP PWR 17 Table 9 460 Watt Power Supply Efficiency 17 Table 10 AC Power Cord Specifications 17 Table 11 Power Factor 18 Table 12 AC Input Voltage Range 18 Table 13 AC Line Dropout Holdup 18 Table 14 AC Line Sag Transient Performance 19 Table 15 AC Line Surge Transient Performance 19 Table 16 Performance Criteria 20 Table 17 460 Watt Power Supply Over Current Protection 21 Table 18 Ove...

Страница 10: ...Intel Storage Server System JBOD2312S3SP Hardware Guide viii This page intentionally left blank ...

Страница 11: ...Connection Mode Overview Appendix A Qualified External Mini SAS Cable List Reference Documents 1 1 Server Product Use Disclaimer It is the responsibility of the system integrator who chooses not to use Intel developed server building blocks to consult vendor datasheets and operating parameters to determine the amount of airflow required for their specific application and environmental conditions I...

Страница 12: ...ng server system with support for 12Gb s SAS or SATA hard disk drives or SSDs redundant fan power and power options and SES communication with the server to monitor the health of the JBOD subsystems This chapter provides a high level overview of the detail for each major system components and features provided in the following sections Figure 1 12 x 3 5 Drive JBOD2000S3 Product Drawing ...

Страница 13: ...Intel Storage Server System JBOD2312S3SP Hardware Guide 3 2 1 Chassis Dimensions Figure 2 Chassis Dimensions ...

Страница 14: ...Air Discharged 12 0 kV Contact Discharge 8 0 kV Acoustics Sound Power Measured Power in Watts 300 W 300 W 600 W 1000 W Servers Rack Mount BA 7 0 7 0 7 0 7 0 System 460W Redundant Power Supplies CRPS operate in spread core flow conditions positive pressure to the power supply s inlet and incorporate a 40mm fan for its own thermal management To ensure PS thermal protection under all operating condit...

Страница 15: ...ent and system configuration It is the responsibility of the system integrator to determine the proper shock level of the JBOD system if the system integrator chooses a different system configuration or different chassis Intel Corporation cannot be held responsible if components fail or the system boards do not operate correctly when used outside any of its published operating or non operating lim...

Страница 16: ...by the platform management subsystem The following table provides a description of each supported LED state Table 3 System Status LED State Definitions Color State Criticality Description Off System is not operating Not ready The system is powered off AC and or DC Green Solid on Ok Indicates that the system status is healthy The system is not exhibiting any errors AC power is present and has been ...

Страница 17: ...er System JBOD2312S3SP Hardware Guide 7 2 3 3 Back Panel Features Figure 6 JBOD2312S3SP Back View Label Description A SFF 8644 receptacle label A PRI B SFF 8644 receptacle label B PRI C PSU D Optional second power module ...

Страница 18: ...bay is not supported Hard disk drive type is dependent on the type of host bus controller used SATA only or SAS Each 3 5 hard disk drive is mounted to a drive tray allowing for hot swap extraction and insertion Drive trays have a latching mechanism that is used to extract and insert the drives from the chassis and lock the tray in place Figure 8 3 5 Drive Tray Assembly Light pipes integrated into ...

Страница 19: ...inks off when processing a command SATA LED blinks on when processing a command Power on and drive spun down SAS LED stays off SATA LED stays off Power on and drive spinning up SAS LED blinks SATA LED stays off 3 2 3 5 Drive Hot Swap Backplane Overview Systems with 12 drive configurations have their own unique backplane The backplanes mount to the back of the drive bay assembly Figure 10 3 5 Hot S...

Страница 20: ...ckplane Cables can be routed from matching connectors on the Expander card Each mini SAS HD connector includes a silk screen identifying which drives the connector supports Drives 0 3 Drives 4 7 and Drives 8 11 B Power Harness Connector The backplane includes a 2x2 connector supplying power to the backplane Power is routed to the backplane via a power cable harness from the power distribution boar...

Страница 21: ...figuration total power available may be less than twice the rated power of the installed power supply modules due to the amount of heat produced with both supplies providing peak power If system thermals exceed programmed limits platform management will attempt to keep the system operational Thermal support is open loop based on ambient temp sensor on the front panel The only power supply option v...

Страница 22: ...Intel Storage Server System JBOD2312S3SP Hardware Guide 12 4 1 Power Distribution Board PDB Figure 14 Power Distribution Board PDB ...

Страница 23: ...with communication over SES2 interface to host PC SMB interface for communicating enclosure status through the expander board to the host system external host controller via SES interface Monitoring capabilities include Fan tachs 12V voltage out from PSU Temperature sensor on front panel Ambient overtemp protection Reported to host system and fan boost only No shutdown Degraded PSU FAN state repor...

Страница 24: ...DB before the system is turned on If the fan runs at 100 at room temperature there is an issue with the SMBUS connection the SAS expander is not getting power or the incorrect firmware is on the expander When a fan fails in the Intel Storage System JBOD2312S3SP an interrupt register bit is set in the ADT7476 Thermal Controller that signals the fan fault register shown below The PMC expander chip o...

Страница 25: ...Intel Storage Server System JBOD2312S3SP Hardware Guide 15 Figure 17 Power Supply Module Mechanical Drawing Figure 18 Power Supply Module Figure 19 AC Power Supply Connector View ...

Страница 26: ...12 12V B12 12V A13 12V B13 12V A14 12V B14 12V A15 12V B15 12V A16 12V B16 12V A17 12V B17 12V A18 12V B18 12V A19 PMBus SDA B19 A0 SMBus address A20 PMBus SCL B20 A1 SMBus address A21 PSON B21 12V stby A22 SMBAlert B22 Cold Redundancy Bus A23 Return Sense B23 12V Load Share Bus A24 12V Remote Sense B24 No Connect A25 PWOK B25 Compatibility Check pin The JBOD s PDB provides several connectors to p...

Страница 27: ...AC input voltage range of 115 VAC to 220 VAC Table 9 460 Watt Power Supply Efficiency Loading 100 of Maximum 50 of Maximum 20 of Maximum 10 of Maximum Minimum efficiency 88 92 88 80 4 5 AC Power Cord Specification Requirements The AC power cord used meets the specification requirements listed in the following table Table 10 AC Power Cord Specifications Cable Type SJT Wire Size 16 AWG Temperature R...

Страница 28: ...ion Requirements The power supply meets all safety agency requirements for dielectric strength Transformers isolation between primary and secondary windings complies with the 3000VAC 4242VDC dielectric strength criteria If the working voltage between primary and secondary dictates a higher dielectric strength test voltage the highest test voltage will be used In addition the insulation system comp...

Страница 29: ...requirements for any rated AC voltage during turn on at any phase of AC voltage during a single cycle AC dropout condition as well as upon recovery after AC dropout of any duration and over the specified temperature range Top 4 6 7 AC Line Transient Specification The AC line transient conditions are defined as sag and surge conditions Sag conditions are also commonly referred to as brownout these ...

Страница 30: ...d in EN 55024 1998 A1 2001 A2 2003 using the IEC 61000 4 4 Second edition 2004 07 test standard and performance criteria B defined in Annex B of CISPR 24 4 6 11 Radiated Immunity The power supply complies with the limits defined in EN 55024 1998 A1 2001 A2 2003 using the IEC 61000 4 3 Edition 2 1 2002 09 test standard and performance criteria A defined in Annex B of CISPR 24 4 6 12 Surge Immunity ...

Страница 31: ... off after an over voltage condition occurs This latch will be cleared by toggling the PSON signal or by an AC power interruption The values are measured at the output of the power supply s connectors The voltage never exceeds the maximum levels when measured at the power connectors of the power supply connector during any single point of fail The voltage never trips any lower than the minimum lev...

Страница 32: ...es Off AC present Only 12VSB on PS off 1 Hz Blink Green AC cord unplugged or AC power lost with a second power supply in parallel still with AC input power Amber Power supply warning events where the power supply continues to operate high temp high power high current slow fan 1 Hz Blink Amber Power supply critical events causing a shutdown failure OCP OVP fan fail Amber ...

Страница 33: ...up to 90 hours per year System performance may be impacted when operating within the extended operating temperature range There is no long term system reliability impact when operating at the extended temperature range within the approved limits All hard drive bays must be populated Hard drive carriers can be populated with a hard drive or supplied drive blank In single power supply configurations...

Страница 34: ...mbly is designed for ease of use and supports several features Each fan is hot swappable Each fan is designed for tool less insertion and extraction from the fan assembly For instructions on installing or removing a fan module see the Intel JBOD2000S3SP Service Guide Fan speed for each fan is controlled by integrated platform management controlled by the PDB When system thermals fluctuate high and...

Страница 35: ...on 1 FAN_TACH1_IN 1 FAN_TACH3_IN 1 FAN_TACH5_IN 2 FAN_BMC_PWM0_R_BUF 2 FAN_BMC_PWM1_R_BUF 2 FAN_BMC_PWM2_R_BUF 3 P12V_FAN 3 P12V_FAN 3 P12V_FAN 4 P12V_FAN 4 P12V_FAN 4 P12V_FAN 5 FAN_TACH0_IN 5 FAN_TACH2_IN 5 FAN_TACH4_IN 6 GROUND 6 GROUND 6 GROUND 7 GROUND 7 GROUND 7 GROUND 8 FAN_SYS0_PRSNT_N 8 FAN_SYS1_PRSNT_N 8 FAN_SYS2_PRSNT_N 9 LED_FAN_FAULT0_R 9 LED_FAN_FAULT1_R 9 LED_FAN_FAULT2_R 10 LED_FAN...

Страница 36: ...3 Expander Processor Internal High Critical 56C 125 High Warning 54C 120 Low Warning 27C 25 Low Critical 22C 20 Actual sensor temperature is 20ºC SES protocol uses a 20ºC offset Front Panel Sensor 1 has a 2ºC offset due to self heating Fan control overrides If Temperature Sensor 3 exceeds its High Warning threshold set Fans to 80 If Temperature Sensor 3 exceeds its High Critical threshold set Fans...

Страница 37: ...rial SCSI Protocol SSP to enable communication with other SAS devices Serial Tunneling Protocol STP support for SATA II through expander interfaces Serial Management Protocol SMP to share topology management information with expanders Supports SES for enclosure management Output mini SAS HD connectors support sideband SGPIO as per SFF 8448 specification Supports both Serial Attached SCSI and Seria...

Страница 38: ...e port Provides up to 12 I2C interfaces Flash ROM A 128 Mbit Quad SPI flash ROM is used to accommodate expander card firmware Heartbeat LED A green LED provides a heartbeat with a 1 second blink rate to indicate the expander has booted properly All JBOD SKUs use the 36 port SAS expander card Single port JBOD2000S3SP SKU has one 36 port SAS expander card See the Intel RAID Expander RES3FV288 User G...

Страница 39: ... C SAS Output ports 8 11 D SAS Output ports 12 15 E SAS Output ports 16 19 F G Internal Input connectors from RAID controller HBA SFF 8643 F SAS Input ports 0 3 G SAS Input ports 4 7 H I External Output connectors to JBOD SFF 8644 H SAS Output ports 20 23 I SAS Output ports 24 27 Figure 24 SAS Expander Port Numbering The Intel RAID Expander RES3FV288 is transparent to users in RAID configurations ...

Страница 40: ...1 2 JBOD2312S3SP Interconnection The Intel Storage System JBOD2312S3SP has a 12x3 5 single port HSBP a primary SAS expander a dual port SAS interface board a PDB a PSU and four fans in its chassis Figure 25 12x3 5 Single port JBOD2000S3SP Interconnection Diagram ...

Страница 41: ...ptacle so SFF 8644 mini SAS cable is needed when connecting the JBOD2000S3SP to host or cascading to other JBOD2000 The following figure is an illustration of SFF 8644 mini SAS cable Figure 26 SFF 8644 mini SAS Cable According to SAS 3 0 specification the length of mini SAS cable has the following rules The 12Gb s SAS cables work up to 10 meters with DFE decision feedback equalization The 12Gb s S...

Страница 42: ...apter that connects to JBOD2000SP3 However only two layers of cascaded JBOD2000S3SP system have been fully validated by Intel Only cascading the same type of JBOD2000S3SP is recommended 7 5 Single port JBOD2000S3SP External Connection Mode The following sections provide the external connection modes supported by the Intel Storage System JBOD2000S3SP single port backplane SKU 7 5 1 Single JBOD2000S...

Страница 43: ...ted to the SAS adapter or cascaded with other JBOD2000S3SP in this scenario SATA or SAS hard drive can be supported Figure 28 Two Single port JBOD2000S3SP Cascade Figure 29 below shows another connection scenario in which the SAS HBA or RAID adapter has two external mini SAS connectors Other group of two cascaded single port JBOD2000S3SP can be connected to the host adapter with one mini SAS cable...

Страница 44: ... but do not provide the full redundancy like a dual domain SAS solution Figure 30 below shows the dual external mini SAS HD connectors of the SAS HBA or RAID adapter connecting to JBOD2000S3SP with two mini SAS HD cables Each single controller port incorporates four SAS lanes for a total maximum throughput of 4800MB s with SAS 3 0 technology SATA or SAS hard drive can be supported The SAS HBA or R...

Страница 45: ...ngle port JBOD2000S3SP systems are cascaded with a mini SAS cable between each B PRI SAS port and a controller connects to each A PRI SAS port with two mini SAS HD cables Any mini SAS HD cable failure will not stop the data transfer between the host and two JBOD2000S3SP Both SAS and SATA drives support this configuration 4 4 4 Figure 31 Dual path with Cascaded JBOD2000S3SP ...

Страница 46: ...ist Vendor Manufactures Part Number Description Amphenol Cables on Demand CS SASMINIHD2 001 1m 3 3 External 4x HD Mini SAS Cable 4x Mini SAS HD SFF 8644 to 4x Mini SAS HD SFF 8644 Passive Copper Cable Assembly 30 AWG 12 Gbps SAS 3 0 iPass HD Compliant Amphenol Cables on Demand CS SASMINIHD2 003 3m 9 8 External 4x HD Mini SAS Cable 4x Mini SAS HD SFF 8644 to 4x Mini SAS HD SFF 8644 Passive Copper C...

Страница 47: ... Hardware Guide 37 Appendix B Reference Documents Refer to the following documents for additional information Intel Storage System JBOD2312S3SP Service Guide Intel High Availability Storage User Guide Intel RAID Expander RES3FV288 User Guide ...

Отзывы: