Intel® Storage Server System JBOD2312S3SP Hardware Guide
9
Table 4. Status LED Status
Amber
Off
No access and no fault.
Solid on
Hard drive fault has occurred.
Blink
RAID rebuild in progress (1 Hz);
Identify (2 Hz). (Dependent on
which RAID controller is used
and attached to the JBOD)
Table 5. Activity LED Status
Green
Condition
Drive Type
Behavior
Power on with no drive
activity
SAS
LED stays on.
SATA
LED stays off.
Power on with drive
activity
SAS
LED blinks off when processing a command.
SATA
LED blinks on when processing a command.
Power on and drive
spun down
SAS
LED stays off.
SATA
LED stays off.
Power on and drive
spinning up
SAS
LED blinks.
SATA
LED stays off.
3.2
3.5” Drive Hot-Swap Backplane Overview
Systems with 12-drive configurations have their own unique backplane. The backplanes mount to the back
of the drive bay assembly.
Figure 10. 3.5” Hot-Swap Backplane and Drive Bay Assembly
There are 12 hard disk drive interface connectors mounted on the front side of each backplane, each
providing both power and I/O signals to the attached hard disk drives.
Figure 11. SFF-8482 Connector on 3.5” HSBP
Содержание JBOD2312S3SP