Intel
®
Server Board S5500BC TPS
Appendix B: Sensor Tables
Revision 1.0
Intel order number: E42249-003
87
Full Sensor Name
(Sensor name in SDR)
Sensor
#
Platform
Applicability
Sensor Type
Event /
Reading
Type
Event Offset
Triggers
Contrib. To
System Status
Assert /
De-
assert
Readable
Value /
Offsets
Event
Data
Rearm
Stand-
by
00 - Power down
04 - A/C lost
OK
As and
De
–
Power Unit Status
(Pwr Unit Status)
01h All
Power Unit
09h
Sensor
Specific
6Fh
05 - Soft power
control failure
06 - Power unit
failure
Fatal
Trig
Offset
A
X
00 - Fully
Redundant
OK
As and
De
–
01 - Redundancy
lost
Degraded
02 - Redundancy
degraded
Degraded
03 - Non-
redundant:
sufficient
resources.
Transition from
full redundant
state.
Degraded
04 – Non-
redundant:
sufficient
resources.
Transition from
insufficient state.
Degraded
05 - Non-
redundant:
insufficient
resources
Fatal
Power Unit Redundancy
1
(Pwr Unit Redund)
02h
Chassis-
specific
Power Unit
09h
Generic
0Bh
06 – Redundant:
degraded from
fully redundant
state.
Degraded
Trig
Offset
A